7601193 (F-STYLE OR NON-MANITOWOC BIN) 7601223 (S-STYLE MANITOWOC BIN) Q-DUAL WATER TROUGH/CURTAIN REPLACEMENT
Installation Instructions
Kit Contents: Water Trough .625 Hole Plug, White 10-32 x 3/4 Phil Fat Type F Screw (2) 10-24 x 1/2 Trim HWH TY23 (2) Trough Protector (2) Water Curtain (2) Ice Deflector Weldment Water Fitting Bracket Control Board Installation Instructions Bushing
Remove:
1. Splash shield (reuse)
2. Water inlet fitting and bracket (reuse fitting - discard bracket)
3. Water pump (reuse)
4. Water curtains (discard)
5. Trough protectors (discard)
6. Water level probe (reuse)
7. Water trough (discard)
8. Ice deflector (discard)
9. Control board (discard)
Before you install:
1. Remove four screws from the water pump mounting bracket. Remove three screws connecting the water pump
housing to the pump motor. Rotate the pump housing clockwise (from the shaft end) one position and then reinstall the screws and mounting bracket (see Figure 3).
2. Remove the water inlet fitting from the water inlet bracket. Save two of the three plastic wing nuts and water inlet
fitting. These will be reused. Discard the bracket.
Install in the following order:
1. New ice deflector
2. New water trough
3. Water pump and reroute water pump supply hose and dump to right side of pump (see Figures 1 and 3)
4. Plug for water level probe and old mounting screw to cover holes - Note! Do not install probe at this time
5. New water curtains
6. New water inlet/water level probe mounting bracket, using screws provided (see Figure 2)
7. Water inlet fitting and water level probe using existing plastic wing nuts - route water inlet probe through
grommet in bulkhead with ice thickness probe wire
8. 1-1/2" bushing in water inlet bracket
9. Water inlet hose through bushing on back of bracket to water inlet fitting
10. New control board
11. Trough protectors
Manitowoc Ice, Inc.
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA 8006823 Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 Sheet 1 of 3 Web Site - www.manitowocice.com 03/25/02
Q-DUAL INSTALL DATA
Water
Water Pump
Trough Protector
Water Inlet Hose 1 1/2" Bushing
Water Curtain
Water Level Hole Plug
Splash Shield
Dump Hose
Water Pump Supply Hose
Water Trough
#10-32 Mounting Screws
Frame Angle
Deflector
Water Inlet/Water Level Bracket Assembly
Figure 1
8006823
Sheet 2 of 3
03/25/02