Manitowoc Ice 20308-130 Installation Manual

Installation For
Model 20308-130
Auto Shutoff Valve Replacement
Model 20308-130 Auto Shutoff Valve
OUT IN
PRODUCT
IN
TO VENT CO2
DISCHARGE
INSTALL HOSE
TO GAS OUT
20 ICON, FOOTHILL RANCH, CA
P/N 1521-000
P/N 1520-000
P/N 20608-100
P/N 20607-100
P/N 20606-100
P/N 20324-30
P/N 1510-000
Flojet Brass CO
2
Inlet Shutoff Valve
Assemblies
Optional Stainless Steel
Product Out Barb Ports
Standard
Product Out
Barb Port
3/8" (9.5 mm)
P/N 20325-030
Slide
Retainer
Clip
Slide
Retainer
Clip
1/4"
(6.3 mm)
1/4"
(6.3 mm)
1/4"
(6.3 mm)
1/4"
(6.3 mm)
3/8"
(9.5 mm)
1/2"
(12.7 mm)
1/4"
(6.3 mm)
ONE YEAR LIMITED WARRANTY
FLOJET warrants this product to be free of defects in material and/or workmanship for a period of one year after purchase by the customer from FLOJET. During this one year period, FLOJET will at its option, at no charge to the customer, repair or replace this product with a new or reconditioned product, but not remove or install, in the event that it is found to be defective in material and/or workmanship.
This Limited Warranty does not include service to diagnose a claimed malfunction in this product at any location other than at Flojet’s corporate head-quarters, nor to repair damage due to improper installation, incompatibility with accessories not manufactured by FLOJET, external electrical fault, accident, or misuse.
All other express and implied warranties for this product including the warranties of merchantability and fitness for a particular purpose, are hereby disclaimed. The product covered by this warranty is marketed and sold by FLOJET as a business rather than consumer product. (Some jurisdictions do not allow the exclusion of implied warranties nor limitations on how long an implied warranty lasts, so the above limitations may not apply to you.)
If this product is not free of defect as warranted above, your sole and exclusive remedy shall be repair or replacement as provided herein. In no event will FLOJET be liable to customer or to any third party for any damages in excess of the purchase price of the product. This limitation applies to damages of any kind including any direct or indirect damages, lost profits, lost investment capital or savings, or other special, incidental, tort or otherwise, or whether arising out of the use or inability to use such product even if FLOJET has been advised of the possibility of such damages or of any claim by any other party. (Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages for some products, so the above limitations or exclusions may not apply to you.)
This warranty gives you specific legal rights. You may also have other rights which may vary from jurisdiction to jurisdiction
.
© Copyright 2001, ITT Industries Printed in U.S.A. All Rights Reserved Form: 81000-049 11/01
UNITED KINGDOM Flojet, Unit 1, Avant Business Centre Denbigh West Industrial Estate Milton Keynes, Bucks, England MK1 1DL Tel: 44 1908 370088 Fax: 44 1908 373731
U.S.A. Flojet 20 Icon Foothill Ranch, CA 92610-3000 Tel: (949) 859-4945 Fax: (949) 859-1153
STEP NO. 1
Turn off CO2supply and open dispensing valve to relieve syrup pressure. Disconnect product IN line.
STEP NO. 2
Move lock on CO2fitting and unplug from Auto Shutoff valve. With a small screwdriver locate the slide retainer clips on the bottom of the pump under the Auto Shutoff valve. There are two (2), one on each side of the valve. (See figure #1). Insert screwdriver and push clips as far as they will go, away from the valve. The Auto Shutoff valve can be removed without tools. Simply pull the valve from the pump base.
STEP NO. 3
Insert new valve. Push valve into pump base as far as it will go, slide clips in and “snap” into place. Plug in CO
2
connection and secure retainer clips.
STEP NO. 4
Reconnect product IN line and reset CO2pressure to normal operating level. Make sure bag connector is fully engaged.
STEP NO. 5
Pump should come on and pressurize syrup line. To test Auto Shutoff valve, remove bag connector and open dispensing valve, pump should shut off automatically. Replace bag connector and pump should operate normally when valve is opened.