Manitowoc Ice 1500-030 Service Manual

1500-030 & 1500-031
Transfer Valve
1500-030 & 1500-031 Transfer Valve
Bag-In-Box Bag-In-Box
Hose Length: 1 foot (305 mm)
Minimum
3 feet (914 mm)
CO
2
Pump
Electric
Pump
Out
In
Label
Indicates Which BIB Is On Line
BIB 1 BIB 2
To Pump
PRODUCT WARRANTY
Flojet warrants this product to be free of defects in material and/or workmanship for a period of one year after purchase by the customer from Flojet. During this one year warranty period, Flojet will at its option, at no charge to the customer, repair or replace this product if found defective, with a new or reconditioned product, but not to include costs of removal or installation. No product will be accepted for return without a return material authorization number.All return goods must be shipped with transportation charges prepaid. This is only a summary of our Limited Warranty. For a copy of our complete warranty, please request Form No. 100-101.
© Copyright 2001, ITT Industries Printed in U.S.A. All Rights Reserved Form: 81000-058 11/01
UNITED KINGDOM Flojet, Unit 1, Avant Business Centre Denbigh West Industrial Estate Milton Keynes, Bucks, England MK1 1DL Tel: 44 1908 370088 Fax: 44 1908 373731
U.S.A. Flojet 20 Icon Foothill Ranch, CA 92610-3000 Tel: (949) 859-4945 Fax: (949) 859-1153
MOUNTING
The Transfer Valve should be located between the bag­in-box cartons with enough hose length for easy bag connector installation & removal. Fixed mounting is not required, however, two holes are provided in the base for mounting on rack or wall if desired. Use only #4 sheet metal screws (m3 screws) or plastic screws.
Maximum thread penetration 3/8” (9.5mm).
HOSE CONNECTIONS
Connect outlet hose from bag-in-box connectors to Transfer Valve barbed ports 1 & 2. Hose should be clamped with stepless or closed Oetiker clamp or equivalent. Make sure there are no bulges or gaps at the clamp that may cause air leaks into the syrup lines. (Prevent damage to hose). Connect hose from Transfer Valve to pump using the same process. See above for recommended installation.
OPERATION
The FLOJET Model 1500 Transfer Valve is fully automatic requiring no operator involvement. To manually operate, simply pull up or push down on the cap. Locate the cap to position that indicates which bag-in-box is on line.
SERVICE INSTRUCTIONS
Field repairs are NOT recommended. Return the Transfer Valve to the factory for warranty consideration.
Recommended installation for C0
2
Pumps or
Electric Pumps
INSTALLATION & SERVICE INFORMATION
Locate Transfer Valve Close To Bag -In-Box
STANDARD MODELS
Number Operating Vacuum inches (mm) Hg.
1500-030 17” ± 2” (432 mm ± 51 mm)
(Recommended for CO
2
Pumps that can
draw 20” Hg. (508 mm) min. vacuum)
1500-031 14” ± 2” (356 mm ± 51 mm)
(Recommended for Electric Pumps that can draw 15” Hg. (381 mm) min. vacuum)