Manitowoc Ice 075M User Manual

Low Air Velocity Unit Cooler
Great Design — Featuring
• 9 Models - 5000 to 34000 BTUH
• Ultra-Quiet Motor Mounting
• Stucco Aluminum Casing
• Ideal for - Fresh Fruits & Vegetables Meat Prep Rooms Floral Storage
Now available with EC Motors High Eciency / High Reliability
Standard Features
Easy Installation
• UL Sanitation listed
• Flush ceiling mount
• Pitched drain pan for level mounting
Full Service Accessibility
• Hinged drain pan
• Removable end panels
U-Section Fan Motor Mounting Rail
• Ultra-quiet motor operation
• Heavy galvanized steel
• Mounted to end plates and tube sheets
• Adds to unit structural strength
All Factory Wiring Run to Numbered Strip
Circuited for New Refrigerants
Internal Expansion Valve Mounting
ENERGY SAVINGS per MOTOR
achieved by changing to more ecient unit cooler motors (based on Energy Cost of $0.10 per kWh)
Motor Change
SP to PSC 120 85 35 22 281 28 $958.94 5.2 $184.41 $18.44 46 0.7
PSC to EC 85 41 44 22 353 35 $1,205.53 5.2 $231.83 $23.18 58 1.1
SP to EC 120 41 79 22 634 63 $2,164.47 5.2 $416.24 $41.62 105 0.9
Std Motor
Power Watts/
SP = Shaded Pole Motors PSC = Permanent Split Capacitor Motors EC = Electronically Commutated Motors
$120
$100
$80
$60
$40
Dollars Saved
$20
$0
1 2 3 4 5 6 7 8 9 10 11 12
Mtr
“Change to”
Motor Power
Watts/ Mtr
Reduced
Power Watts/
Mtr
Run Time
Hrs/ Day
Motor Energy
Savings kWh/Yr
Yearly Savings per motor
Months of year
Motor Energy
Savings $/Yr
Reduced Box
Load MBTU/Yr
Cond. Unit
EER
Cond. Unit
Energy Savings
kWh/Yr
Cond. Unit
Energy Savings
$/Yr
Yearly
Savings $/Yr
Payback
Yrs
SP to PSC PSC to EC SP to EC
Performance Data
Capacity in BTUH
MODEL
NUMBER
050M 580 5000 6000 7500 9500 10500 11600 14500 075M 800 7500 9000 11250 14200 16200 17400 22200 100M 1110 10000 12000 15000 19000 21200 23200 29100 130M 1720 13000 15600 19500 24700 27600 30200 37800 160M 1720 16000 19200 24000 30400 35100 37200 47600 190M 2330 19000 22800 28500 36100 41000 44100 55900 220M 2290 22000 26400 33000 41800 48300 51100 65500 270M 2860 27000 32400 10500 51300 59500 62700 80500 340M 3420 34000 40800 51000 64600 75200 79000 10170
CFM
General Cooler Applications*
30º to 45º Room Temperature
10º TD 12º TD 15º TD Sensible Clg. Total Clg. Sensible Clg. Total Clg.
Prep Rooms @ 30º Evaporator Temperature
50º DB/55% RH 55º DB/55% RH
Ordering Information
All stock unit coolers are circuited for
operation from 9º to 12º TD.
Applications
EFA units are suitable for rooms +35º F & above
EFE & EFG units are suitable for rooms +28º F & above
Special circuiting may be required for
other TD’s. Please contact factory.
Please Specify:
Model Number
Motor Type Motor electrical-volts/hertz/phase Heater electrical-volts/phase Evaporator temperature - ºF
Refrigerants
All stock units are suitable for R-22, 134a, 404A, 502,
507, R401A (MP-39) and R402A (HP80)
50 Hertz Power
Divide the BTUH requirement by 0.92, then select the
unit cooler directly from the table above.
Design TD or operating capacity Liquid temp. at TX valve (100º F is standard) Refrigerant
Air Throw
Up to 15 feet based on 9’ ceiling and no obstructions
Electrical Data
SHADED POLE MOTOR DATA PSC MOTOR DATA EC MOTOR DATA
MODEL
NUMBER
050M 1 1.9 120 1.0 120 0.54 120 1.0 85 0.5 85 0.68 41 0.34 41 075M 2 3.8 240 2.0 240 1.08 240 2.0 170 1.0 170 1.36 82 0.68 82 100M 2 3.8 240 2.0 240 1.08 240 2.0 170 1.0 170 1.36 82 0.68 82 130M 3 5.7 360 3.0 360 1.62 360 3.0 255 1.5 255 2.04 123 1.02 123 160M 3 5.7 360 3.0 360 1.62 360 3.0 255 1.5 255 2.04 123 1.02 123 190M 4 7.6 480 4.0 480 2.16 480 4.0 340 2.0 340 2.72 164 1.36 164 220M 4 7.6 480 4.0 480 2.16 480 4.0 340 2.0 340 2.72 164 1.36 164 270M 5 9.5 600 5.0 600 2.70 600 5.0 425 2.5 425 3.40 205 1.70 205 340M 6 11.4 720 6.0 720 3.24 720 6.0 510 3.0 510 4.08 205 2.04 205
No.
Motors
115/1/60*
TOTAL
AMPS WAT TS AMPS WATTS AMPS WATTS AMPS WAT TS AMPS WATTS AMPS WAT TS AMPS WATTS
208-230/1/60
TOTAL
460/1/60**
TOTAL
115/1/60*
TOTAL
208-230/1/60
TOTAL
115/1/60*
TOTAL
208-230/1/60
TOTAL
Model
Number
ELL 050M 4.3 2.2 1000 ELL 075M 4.3 2.2 1000 ELL 100M 4.3 2.2 1000 ELL 130M 10.4 5.2 2400 ELL 160M 10.4 5.2 2400 ELL 190M 10.4 5.2 2400 ELL 220M 10.4 5.2 2400 ELL 270M 17.4 8.7 4000 ELL 340M 21.7 10.9 5000
208-230V
1 Ph
Defrost Heater Data
AMPS - 60 HZ
460V
1 Ph
Total Watts
* 115v/1 Not Available for electric defrost models ** 460/1 Not available for PSC or EC motors
50 Hertz Power
208-230 volt units are suitable for 50 HZ voltage from 187-220. Contact factory if job site voltage is beyond this range. 50 HZ motor watts = 60 HZ. motor watts x 0.83
2915 Te nn es see Ave norTh, PArs on s, Tn 3836 3 • 1-8 77 -759- 90 19 • FAx 1 -731- 84 7-901 2
Nomenclature
AM L 190 M D P
DEFROST TYPE AM—Air EL—Electric
MODEL SERIES
L—Low Velocity
BTUH in Hundreds
TEMP. APPLICATION M—Medium
Dimensional Drawing
RD I
MOTOR TYPE S - Shaded Pole
P - Permanent Split Capacitor E - Electronically Commutated Motor
ELECTRICAL CODE A—115/1/60 D—208-230/1/60 F—460/1/60 L—200-220/1/50
Dimensional Data
Model
Size
050M 7 7 1/2 35 48 7/8 2.6 76 075M 7 7 3/4 54 67 7/8 5.0 117 100M 7 7 3/4 54 67 7/8 5.0 120 130M 8 1/2 9 3/8 36 85 1 1/8 6.1 149 160M 10 10 7/8 36 85 1 1/8 9.8 171 190M 13 13 7/8 36 85 1 1/8 9.8 182 220M 13 13 7/8 36 85 1 1/8 13.0 201 270M 13 14 41 1/2 96 1 3/8 14.9 260 340M 13 14 1/4 35 11/16 120 1 3/8 17.7 344
A B
Dimensions in Inches
Mounting Slot Centers
C D E
L
Suction
Conn.*
ODM
Approx.
R-22
Charge
*Other Connection Sizes
Liquid — 1/2" ODM Ext. Equal. — 1/4" ODM
Drain — 3/4" FPT
Specications weights and dimensions are subject to change without notice
SolutionS
RDI provides many of the operational solutions from Manitowoc Foodservice, a global company dedicated to bringing value to foodservice operators by equipping them with highly individualized real-world answers that enhance menus, service, profits and efficiency.
Approx.
Shipping
Weight
To learn how Manitowoc Foodservice and its leading brands can equip you, visit our global web site at www.manitowocfoodservice.com then find the regional or local resources available to you.
©2009 Manitowoc Foodservice except where explicitly stated otherwise. All rights reserved. 4598 12/09