Manitowoc KH0179 Instructions Manual

KH0179 - IB-0620/0820/1020 ON A CORNELIUS
30.00” WIDE ICE DISPENSER (ENDURO 200/250)
Installation Instructions
1. Set adapter on top of the dispenser. Position the bin cover so that the front flange of the bin cover will lock under the
front lip of the dispenser. Adapter may have to be moved towards the back of the dispenser.
NOTE: Do not drill deeper than 1/4” past the sheet metal. Use a drill stop!
3. Fasten adapter to dispenser using the four (4) #8 screws supplied with the adapter kit.
4. Set the ice machine on top of the adapter. Align holes in ice machine front angle with the rivnuts on the adapter.
5. Secure the ice machine to the adapter with two (2) #8-32 screws supplied with the kit.
6. Set the front bin cover onto the dispenser. The back flange of the bin cover will latch onto the adapter.
7. Rotate retaining arms into position, as shown for normal ice machine operation.
LH Retaining Arm
Bin Cover
Manitowoc Ice, Inc.
2110 South 26th Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 8006693 Web Site - www.manitowocice.com Rev. 06/17/03
#8-32 Screw Two (2) Places
Adapter
#8 Screw 4 Places
RH Retaining Arm
Cornelius ED200/250 Dispenser