Manitowoc FLOMATIC 464-GP Quick Manual

The Flomatic 464-GP valve provides superior performance and exceptional durability for the life of the valve. The GP features a broad operating range from 2 to 4 oz./second to meet global dispensing requirements. The GP is available in sanitary push lever, push button, automatic fill lever, and portion control models. With all models, mounting and ratio control are the same.
All Flomatic valves are identified by a Model Number, Serial Number, a manufacture month and year on the underside of the flow control base. These numbers are a helpful reference before beginning any valve service.
INSTALL OR REPLACE A VALVE
Flomatic created a kit (5007842) to replace both the 372-Q or 380-Q Flomatic mounting blocks. All Flomatic mounting blocks are identical in appearance, except for the part numbers shown on the front recess of the block. The 380-Q has inlet ports sized at 0.380 in. and is compatible with Lancer or UF-1 fittings. The 372-Q inlet ports are sized at 0.372 in. and accommodate a Cornelius SF-1 fitting. Select the appropriate mounting option and install the mounting block. Wet the inlet O-rings with water to ease installation; do not use Vaseline®. Align the four bolt holes and mount.
Be sure to relieve the system pressure before removing or repairing the mounting block.
Remove the valve cover and align the valve stems with the mounting block. Independent positive shut-offs and the locking system prevent removal while the system is pressurized. The valve cannot be removed unless the shut-off valves are closed (arrows pointed across service line).
The mounting hole pattern typically has key slots to secure the product supply lines. If no key slots are present, use the “S” clip option.
Engage the valve and depress the latch pin. Do not force or you could bend the pin. If you have difficulty, remount the valve and try again. Be sure the valve base is completely seated against the block. Open the shut-off valves by turning 1/4 turn (arrows pointed toward service line) to engage system pressure.
SET FLOW RATE AND RATIO CONTROL
To simplify installation, the soda flow rate is optimized for cold carb operation and is preset at the factory: 3.125 oz./second soda flow rate is standard for the 464-GP. Should field conditions require adjusting the flow rate, clockwise movement of the adjustment screw increases the flow rate and vice versa. Ceramic flow controls can be adjusted from 2 oz./second to 4.0 oz./ second total flow rate on the GP valve.
SET RATIO CONTROL
You will need a syrup separator, hex wrench (5/32 Allen), and brix cup. Place the Flomatic S-tube syrup
separator (part no.1089-00) over the syrup diffuser. You need not remove the nozzle.
Most brix cups are calibrated for the standard 5:1 ratio. Adjust the syrup flow by moving the adjusting screw until the desired ratio is established.
INSTALL ADD-A-LEVER FOR “SODA ONLY”
The Flomatic Add-a-Lever is a two-piece assembly which mounts on the pivot pin. Simply remove the cover, partially withdraw the pivot pin to allow mounting, reinsert the pin, replace the cover and you’re done.
CONVERT TO PORTION CONTROL
Flomatic portion control electronics are contained in the cover and can be factory or field installed. When installing in the field, the 5031015 Conversion Kit for the 464-GP makes it easy to add portion control.
The portion control module is designed to simplify installation. The board can be programmed with the first pour.
The “Stop/Fill” button serves as a top-off button and cancels any of the timed portions if you need to abort the pour.
Each cup size must be programmed separately. Cup sizes are preprogrammed at the factory: 1 second = small, 2 second = medium, 3 second = large, 4 second = x-large.
Set the flow rate first, brix the valve, and then set the cup sizes to match your desired flow rate. Once the valve is brixed, replace the valve cover and set the times (cup sizes) from the front switch pad.
The switch pad has a hidden “program” switch that must be held down to keep the module in program mode. Setting the times or programming is a two-handed operation; push and hold the program switch with one finger while dispensing the cup size you wish to program with another. Once the drink is full, simply release the cup size button to end the pour cycle and then let go of the program switch. Repeat the process for each cup size.
The module will remember one top-off cycle automatically if the foam height requires it to complete the pour. T o program a top-off cycle, begin programming as described above. Once the foam crests the top of the cup, PAUSE by removing your finger from the cup size button. Do not release the program button. Pause long enough for the foam to settle, and then continue the pour with your finger on the same cup size button until the cup is full. The module will remember the sequence “pour - pause - pour” as it was executed.
If you program the top-off feature, be sure to train the operators so they do not pull a drink before the cycle is complete. The portion control module will finish the pour whether a cup is there or not.
AUTOMATIC FILL VALVE
The 464-GP Automatic Fill valve can be used to dispense both carbonated and noncarbonated products. The valve is factory set for carbonated products where a delayed top-off is standard, and the wire-lead plug should be attached to pins 1 and 2 (those furthest to the left). If your installation uses noncarbonated products requiring
Valve should seat securely
Shut-off closed Hidden Program Switch
no top-off, you will need to adjust the position of the lever wire-lead plug on the electronics. For noncarbonated products, the wire-lead plug should be attached to pins 2 and 3 (those furthest to the right), as shown in the photo.
The Automatic Fill valve requires no sensitivity adjustments. The valve automatically delays top-off if more foam is present after the initial pour, and performs a top-off more quickly if less foam is present.
CLEANING
Under normal operating conditions, periodic cleaning is minimal but absolutely necessary. Remove the nozzle assembly as shown, soak it in warm water, rinse and reinstall. Brush the lever slot with warm water to prevent syrup build-up and sticking. Wipe cover and panel with a clean cloth and you are finished. Nothing more needs to be done unless you experience a problem.
Regular servicing and cleaning of the complete beverage system is advised to maintain proper functioning of the equipment. Be sure to follow instructions provided by the manufacturer.
If refurbishing a piece of equipment, remove the solenoid from the valve. Once removed, the entire valve can be submerged in warm water for cleaning.
3
2
1
FLOMATIC 464-GP POST -MIX V AL VE QUICK GUIDE FOR INSTALLATION & MAINTENANCE
QUICK GUIDE FOR INSTALLA TION AND MAINTENANCE
GET TO KNOW THE 464-GP THE ONE VAL VE DESIGNED TO MEET GLOBAL PERFORMANCE REQUIREMENTS
Q-035-FL
REV 01-09-08
Manitowoc Beverage Equipment
2100 Future Drive
Sellersburg, IN 47172-1868 USA
TOLL-FREE: (800) 367-4233
TEL: (812) 246-7000 FAX: (812) 246-9922
Use this handy Quick Guide to install and perform routine maintenance on your 464-GP valves.
TROUBLESHOOTING
Occasionally, a valve will not perform as desired. Here are some helpful tips for troubleshooting:
RATIO: Look for foreign matter in the adjustment screws, flow controls or pallet seats. If a system is not flushed completely at start-up, foreign particles may be introduced into the system. Reset the flow rate and readjust the syrup ratio.
BUZZING: Do not lubricate the plungers. If contaminated, simply wash with hot water, dry and reinstall.
LEAKS: Check for damaged or improperly fitted O­rings. The slightest piece of hair, dust, etc., on the sealing surface may contribute to a leak. When in doubt, replace an O-ring. Be sure you have the correct O-ring and fitting combination for the respective mounting plate.
For further technical assistance, call Manitowoc Beverage Equipment at 1-800-367-4233.
Manitowoc Beverage Equipment
guarantees all Flomatic products free from
FLOMATIC WARRANTY
GET STARTED HERE
No. Part No. Description
1 5007842 MTG BLOCK 0.380 2 505 SCREW 4-40X1 3 507-36-G DIFFUSER BLOCK 464 4 509 ORING 112 5 510 SCREW 4-40X5/8 6 511-04 SPRING COIL PALLET RETAINER 7 512-02-G ORIFICE CAP GP LFT BLK 8 513-02-G ORIFICE CAP GP RT BLK 9 515-30 PALLET BEARING PAD SET 10 515_02 PALLET HIGHFLOW 11 516-06 LEVER SANITARY SS (SSL) 12 516-07 EURO LEVER PL BLK 13 516-09 LEVER SANITARY MOLDED 14 516-10 A UTOFILL LEVER SENSOR 15 517-05 LEVER RETAINER ELEC LG 16 524-02 PIVOT PIN LONG 17 526 SHUTOFF PLUG 18 527 SEAL SHUTOFF 19 528 SEAL QUAD VLV STEM 20 530 BEARING PALLET 21 538-04 LATCH PIN
No. Part No. Description
22 543 O-RING (010) 23 551 ORING 012 24 553-00 SCREW #6 X 3/8 25 562-80 BODY 380Q 26 564 S-CLIP 27 565 SCREW 8X1/2 28 567 RETAINER SHUTOFF PLUG 29 568 RETAINER QUAD STEM SEAL 30 600-47-G FLOW CTRL BASE 464 #8 31 602-03 CYLINDER HF 32 602-03-G CYLINDER GP 33 603-03-G PISTON SYRUP GP 34 604-04-G PISTON SODA GP 35 605-02 SP RING FLOW CTRL HF SODA 36 607 SCR FLOW RATE ADJ M 37 608 ORING 017 38 609-02 NU T BRIX ADJ 464 39 610-04 RE TAINER PLATE 6-32 40 643-00 FLOW RATE ADJ 464 GP 41 774-A36 SOL AUTOFIL SNGL AC 42 774-E36 SOL MSL SNGL YOKE AC
No. Part No. Description
43 774-P36 SOL PCTRL SNGL YOKE AC 44 817-04 HARNESS CPM 45 835 PC MODULE 4 CUP 46 1028 ADD-A-LEVER 464 47 1028-S ADD-A-LEVER 464 SO 48 1028-W ADD-A-LEVER 464 WTR 49 1601 COVER BASE 50 1602 COVER PL FRONT 51 1610 COVER GP FRONT PB 52 9774-1 SOLENOID ASSEMBLY 53 5011953 SCR 10-24X1-1/4 SELF TAP 54 5028273 ORING SLEEVE 55 5030418 SWITCH, PCTRL 56 5030419 SWITCH, MSL 57 5030421 SWITCH, AUTOFILL 58 5031015 KI T AC PCTRL CONV 464 59 5031018 KI T AC AUTOFILLCONV 60 020001284 SCR #8 X 5/8 PH HI-LO 18-8 61 020001750 464 NOZZLE ASSEM
COMPLETE VALVE ASSEMBLIES
- 464GPS361625 Push Button
- 464GPE361621 Sanitary Lever
- 464GPA361621 Autofil
- 464GPP361600 Portion Control
FLOMATIC 464-GP POST -MIX V AL VE QUICK GUIDE FOR INSTALLATION & MAINTENANCE
FLOMATIC 464-GP POST-MIX V AL VE
Loading...