T h e S ile n c ioTM operators are 4X Q U IETER than our “Prem ium Trolley A partm ent” M odel O TBH-A 05.
For more information, please visit www.devancocanada.com or call toll free at 855-931-3334
2
TABLE OF CONTENTS
Installation Instructions............................................................................................................................................... 3
1 General Specifications and Dimensions (OTH-A.06)..........................................................................................................................................4
2 General Specifications and Dimensions (OTBH-A.06)........................................................................................................................................5
3 SilencioTM Apartment Style Trolley Operator Installation...................................................................................................................................6
3.1 Assembly Instructions...............................................................................................................................................................................6
3.2 Installation.................................................................................................................................................................................................8
Notes............................................................................................................................................................................ 10
Warranty....................................................................................................................................................................... 11
3
Installation Instructions
IMPORTANT INSTALLATION INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF SEVERE INJURY OR
DEATH TO PERSONS:
1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
2. Install only on a properly operating and balanced door. A door that is operating
improperly could cause severe injury. Have qualified service personnel make repairs
to cables, spring assemblies and other hardware before installing the operator.
3. Remove all pull ropes and remove, or make inoperative, all locks (unless
mechanically and/or electrically interlocked to the power unit) that are connected to
the door before installing the operator.
4. Installation of this door operator must be done by a qualified installer.
5. Verify that the operator is correct for type, size of door and frequency of use per the
operator specifications.
6. Install the door operator at least 8 feet (2,44 m) or more above the floor if the operator
has exposed moving parts. Covers or guarding, provided by the manufacturer, must
be installed when the operator is mounted less than 8 feet (2,44 m) above the floor.
7. Do not connect the door operator to the source of power until instructed to do so.
8. Locate the control station: (a) within sight of the door, (b) at a minimum height of
5 feet (1,5 m) above floors, landings, steps or any other adjacent walking surface so
small children cannot reach it, and (c) away from all moving parts of the door.
9. Install the Entrapment Warning Placard next to the control station in a prominent
location.
10. For products having a manual release, instruct the end user on the operation of the
manual release.
4
1 General Specifications and Dimensions (OTH-A.06)
SUPPLY VOLTAGE...............................115, 230 VAC single-phase, 208, 460, 575 VAC three-phase
CONTROL VOLTAGE............................24 VAC class 2 transformer, 2 amp fuse type ACG
MOTOR.................................................Continuous duty 1/2, 3/4 horsepower
DOOR SPEED......................................9” / second
NET WEIGHT (Operator only)...............71 Lbs (32 Kg)
STANDARD WIRING TYPE..................C2 (momentary contact to open/stop and constant-pressure-to-close)
APPLICATION.......................................Heavy duty for standard lift sectional doors with high cycling daily frequency
requirements
DUTY.....................................................>100 cycles/day
Figure 1 - SilencioTM Dimensions OTH-A.06
Table 1 - OTH-A.06 SilencioTM Operator Selection Guide
Maximum Area in Square Feet (general guideline)
Sectional Doors
Steel
HP
18 ga ins.
½ 196 245 314 343 392
¾ 270 319 441 490 549
Steel
18 ga
20 ga ins.
Steel 20 ga,
22 & 24 ga
Wood
ins.
Alu. Steel
22 & 24 ga
Fiber
Glass