SAFETY INSTRUCTIONS
Please read the instruction manual carefully before using the unit.
• Check that the unit has not been damaged during transportation. Please contact your dealer if the dehumidifier is damaged.
• IMPORTANT: If the unit has been kept in a horizontal position, make sure to place it upright for at least an hour for refrigerant to settle be­fore use. Failure to do so may cause damage to your unit.
• Make sure to place the unit on a level and stable surface.
• DO NOT use extension cord.
• Make sure to protect all electric cables outside the unit from damage.
• DO NOT block or cover air intake and air outlet, particularly when the
unit is operating.
• DO NOT use the unit without the AIR FILTER. Keep the suction side always free from dirt and loose objects.
• DO NOT unplug the unit if your hands are wet. Electrical shock could occur.
• Never put objects on top of the unit or insert into the unit, particularly when the unit is operating.
• Always switch off the unit with the power switch first, before you un­plug the supply cable from the wall socket.
• DO NOT transport the unit during operation.
• Make sure to empty the water tank before transporting the unit.
• Make sure to transport the unit only in a vertical position.
• Damage on the compressor will be avoided by waiting at least 3 min-
utes before re-starting the unit.
• If the supply cord is damaged, it must be replaced by a qualified electri­cian.
3
Air Outlet Grill
Control Panel
Supply Cable
Wheel
Transport Strap
Stand Strap
PRODUCT DESCRIPTION
Air Inlet Grill
Air Filter
Door Knob
Sight Plate
Stopper Mat
Hole for
water hose
4
CONTROL PANEL
1. Main Switch – If you switch on the unit on the main switch, it will run in a fully automatically operation.
2. Power Lamp – If you switch on the main switch, a green control-lamp “power” will illuminate.
3. Full Water Lamp – When the water tank is full, this yellow control­lamp “full water” will illuminate.
4. Hour Counter – The collect time of operation will be recorded by an hour counter.
DESCRIPTION OF FUNCTIONS
Switch on the unit. The green pilot lamp illuminates. The ventilation fan sucks in the moist ambient air via the air filter, the evaporator and the condenser. Heat is extracted from the ambient air at the cold evaporator. The air is cooled to below the dew point, and the water vapour contained in the air is accumulated as condensate water on the evaporator fins and then drops down into the water tank. As a low temperature of ambient air is sucked, the water vapour becomes to hair-frost on the evaporator fins. When the temperature sensor measures a specific low value of the evaporator’s surface, a timer is activated with a delay of about 30 minutes. If during this period the evaporator’s temperature does not rise again, the refrigeration cycle will switch to hot gas defrost after the time reach. Dur­ing the defrost cycle, the ventilation fan is off. As it has defrosted and the
OPERATING DESCRIPTION
This unit has been designed for automatic operation and problem-free air dehumidification. This unit works according to the air condensation prin­ciple and is equipped with a hermetically sealed refrigeration system, as well as with a maintenance-free ventilator. The water container include an overflow-protection equipped with a float-switching device and a drain­age hose-nipple for continuous operation.