Malloca MDC-21C User Manual

HANGING STERILIZING CUPBOARD
MÁY KHỬ TRÙNG CHÉN DĨA
USER MANUAL
HƯỚNG DẪN SỬ DỤNG
MODEL: MDC-21C
Vui lòng đọc kỹ hướng dẫn trước khi sử dụng thiết bị và giữ nó cẩn thận.
Neutral line
E
N
L
1
Thanks for using Malloca disinfection cabinet. Malloca disinfection cabinet keeps clean and dries the tableware and appliance disinfected with ozone, UV in the right cabinet and sterilize by far infrared in the left cabinet. The product can kill colon bacillus, staphylococcus and bacteria causing hepatitis. It is an ideal disinfection cabinet for the restaurant, kindergarten, hotel, dining hall and other places.
Warning
Only when the right door is closed can the disinfection cabinet work normally, otherwise there will be leak of ozone. Do not put any other thing than tableware into the disinfection cabinet. In order to achieve the best disinfection result and avoid burning your hands or leak of ozone, you are suggested to wait for another 20mins before opening the door after the sterilizing is finished and do not take out the tableware before they cool down. Cannot put the plastic and wooden product into the left cabinet. High temperature, please be careful not to get burnt.
Special Attention
For the tableware of which heat-resistance is below 75 should not be placed in the cabinet. For the tableware of which heat-resistance is below 180, such as high temperature resistance plastic materials, silicon rubber product or low temperature resistant glass products should not be put into the left cabinet. The tableware of which heat-resistance is between 180 to 250 should be put away about 100mm from the heat pipe.
Precautions
The power supply socket must be reliably ground. The user should not change the socket by himself.(Please
Ear then li ne
refer to picture 1). The tableware should be dry before putting into the cabinet and shouldn't be overlapped to obtain the best sterilizing effect. Don't touch the glass of the door when it is sterilizing for avoiding being scalded. Don't block the Air-off hole. When the maintenance work is required, the power supply should be turned off first. Don't put the disinfection cabinet near the tinder and the cloths things are not allowed to put into, on or beside the cabinet. Please turn off the power supply after sterilizing or finish cleaning. As to the special people (like children) are not suitable to use this disinfection cabinet.
How to handle the junk product: for the junk appliances which excess the safety life or not available with the repair value, the user should take the appliance to the recycle enterprise, household appliance agent or after-sales service center. The user is not allow to throw away the junk appliance by themselves
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
left cabinet
The
right
cabinet
The
+45
125
- 5
Model
Power supply
Rated input power
Interior volume
Sterilizing temperature
Working time
Ozone concentration
Work cycle (load)
Life span for the ozone generator
Power of ozone UV lamp
Life span for the heat pipe
Work cycle (load)
Rated loading weight of each rack
Net weight
Exterior dimension
MDC-21C
220V 50Hz
500W(Left cabinet 400W,right cabinet 100W)
60L(30L for the left, 30L for the right)
≥15mins
5mg/m
3
≤ozone concentration≤30mg/m
3
≥30mins
≥20mins
≥1000h
≥3000h
6W
5kg
14kg
795 * 373 * 395mm
Major Technical Data
1.. Body of cabin . Bowl ra2. . Air-ho3. . Temperatu4.
control (1)
. Dish ra5. . Bowl ra6.
7.. Ozone produc
8.. Temperatu control (2)
9.. The right do
10.0. Dish r
11.1. Heat pipe
12.2. Power
3. Heat pipe13.
14.4. The left d
Names of Components
Features
With fashionable outlook design and attractive shape. The product can control separately by left and right cabinet. With temperature increase to above 120℃, the infrared ray produced in the left cabinet can kill 99.9 percent of the colon bacillus, staphylococcus and showing negative effect in the (HBsAg) damaging experiment, but does no side-effect on human health. Ozone in the right cabinet disinfects the colon bacillus and the staphylococcus to some extent, and it is fit for keeping clean the tableware of which is not high temperature resistant. The left and right cabinet can control exactly, it's safe and reliable.