Mallinckrodt INOmax DS, INOmax DS IR, INOvent User Manual

IMPORTANT: This guide is provided as a convenience and for General Information only. Never use this product without clearly and thoroughly understanding the most recent revision of the INOmax DS, INOmax DSIR and INOvent Operation Manuals. The Operation Manual is the source
for specic, updated information regarding warnings, cautions, checklists, diagrams, and/or
instructions contained in this guide.
For assistance contact Technical Support 877-566-9466
WARNING:
1. Avoid recirculation of gases. Undesired recirculation of gases
will occur if fresh gas ows are less
than the patient minute volume and may result in:
• Higher NO2 levels due to the limited ability of the carbon dioxide absorbent to remove NO2.
• Higher concentrations than those set due to NO recirculated through the absorber.
• Reduction in O2 concentrations because nitrogen is the balance gas for nitric oxide and will be present in the re­circulated gases.
2. If the Injector Module was used
in the wet/humidied part of the
breathing circuit, it should be sterilized between each patient use.
Caution:
1. Note airow direction on the Injector Module: the ow out of the
absorber must pass through the Injector Module in the direction of the arrow on the module.
2. Nitrous oxide (N
2
O) will affect the Set NO versus the measured NO value. For a 50% N2O, 50% O2 composition, the measured NO value will be approximately 7% indicated less than the same Set NO value of 100% O2. For example, at a Set NO of 20 ppm, measured NO will be approximately 18 ppm.
3. Similarly, the effect of 2%
v/v isourane will result in a
high measured NO value of approximately 3% indicated for the same Set NO value at 100% O2.
4. Sudden changes in anesthetic agent concentration may cause brief transient changes in the measured NO and NO2 values.
Connection to a Circle Anesthesia Ventilator System
IMPORTANT: This guide is provided as a convenience and for General Information only. Never use this product without clearly and thoroughly understanding the most recent revision of the INOmax DS, INOmax DS
IR
and INOvent Operation Manuals. The Operation Manual is the source
for specic, updated information regarding warnings, cautions, checklists, diagrams, and/or
instructions contained in this guide.
1. Patient wye
2. Gas sample line
3. Sample line inlet
4. INOmax DS / INOmax DSIR /
INOvent delivery system
5. Bellows assembly
6. Ventilator drive gas line
7. Ventilator (rear view)
8. Absorber
9. Absorber expiratory port
10. Absorber inspiratory port
11. Injector Module A. input B. output
12. Injector module cable
13. Injector module tubing
14. Inspiratory hose
15. 22M / 15F X 22M / 15F Adapter
16. Sample Tee
See applicable warnings and cautions on page 1 of this document.
Note:
1. With a circle anesthesia breathing circuit, the
INOmax DS / INOmax DS
IR
/ INOvent delivery system will perform as specied in the technical specications with
fresh gas ow rates equal to or
greater than the patient minute volume.
2. The breathing circuit between the sample tee and the patient Y should be between 6 and 12 inches (150 -300mm) long: greater than 6 inches to
minimize the sampling of mixed inspired/expired
concentrations and less than 12 inches to help ensure correct NO2 measurement.
3. For OR ventilation systems with the inspiratory
ow measurements at the inspiratory port of the
absorber, place the Injector Module upstream of
the inspiratory ow sensor.
Connection to a Circle Anesthesia Ventilator System
Mallinckrodt Manufacturing LLC, 6603 Femrite Drive, Madison, WI 53718-6801 USA
For assistance contact Technical Support 877-566-9466.
1
16
15
14
11b
8
6
11 11a
4
5
7
9
2 3
10
13
12
INOmax DS INOmax DS
IR
INOvent
Part No. 20731 Rev-01
2014-08