Device Introduction
Battery Compartment
LED Flashlight
360° Detection Tip
On / Off
Control Unit
Vibration / Audio & LED
Sensitivity Control
IP Rating:
IP67 - Dust resistant and waterproof up
to 1 meter depth.
Page 3
A) To install the battery, twist and remove the fastener marked with number 1.
B) To remove the control unit marked with number 2 from the device, pull WITHOUT TWISTING.
C) Insert the battery facing downwards paying attention to plus (+) and minus (-) poles. The device will not work if the battery is not installed correctly.
D) To mount the control unit (2) back on the device, align the contact pins and the notches marked with number 3 and push to snap in. DO NOT TWIST THE CONTROL UNIT!
E) Twist the fastener (1) and do not leave it loose to secure a water tight seal.
Battery Installation
12
Battery
3
Page 4
Turning on the Device
Press and release the Green on/off (+) button once. The LED will light up and a long warning tone will be heard. Makro Pointer is ready for use. Be sure there are
no metal objects around at start up.
Mode Change
Press the Red (-) button for 3 seconds. A short warning tone will be heard. The device will switch from the
audio mode to the vibration mode. When pressed and held again, it will switch to the audio and vibration mode. If pressed again, it will revert back to the audio mode. A short warning tone will be heard with each mode change. Makro Pointer will start at the same setting the next time you start up the device.
Sensitivity Increase
Double click the Green on/off (+) button to increase
sensitivity. Sensitivity has 4 levels. The factory preset
setting is level 3. The device indicates the sensitivity level with the number of warning tones. Makro Pointer will start at the last adjusted sensitivity level at start up.
Turning off the Device
Press and hold the Green on/off (+) button. Six (6)
short warning tones will be heard and the device will
turn off.
Page 5
Detection Tip
Makro Pointer's detection area is between the tip and
the hand grip. The coil provides 360° detection. This helps you to locate targets quickly and easily in the hole. If you hold the device horizontally, you can scan a larger area. This allows you to cover a broader area to quickly reach your target.
Sensitivity Decrease
Double click the Red button to lower sensitivity. Sensitivity level is indicated by the number of warning tones. Makro Pointer will start at the last
adjusted sensitivity level at start up.
Detection
Tip
LED Flashlight
Press the Red button once to turn it on, press again to turn off. Makro Pointer will start at the same setting at start up.
Low Battery Indicator
When the battery is low Makro Pointer will give 5 short-long beeps at the start up. The device may continue to work for a short period of time.
Coil Interference Blocking
When it is switched off, it disconnects the coil's magnetic transmission and eliminates interference with another metal detector. This also prevents the device from being detected as a target.
Page 6
Replaceable Hard-Shell Cases
Makro Pointer comes with two hard-shell cases. One of the cases is also designed to allow for digging.
Usage
When a target is detected, Makro Pointer will produce an audio and/or vibration alert. The rate of the pulsing audio or vibrations will increase as it gets closer to the target and it will decrease as it is moved away.
TECHNICAL SPECIFICATIONS
Working Frequency Metal Detection Sensitivity Coil Interference Blocking Dimensions
Detection Tip Weight
Working Temperature Battery Battery Life
11.6KHz Audio and / or vibration alert 4 levels manual Yes
9.4”x1.9”x1.9” (24 x 4.8 x 4.8cm) including the hard-shell digger case
3.7'' (9.3cm)
8.3 oz (235 gr) including the battery and hard-shell digger case
-4°F / +122°F (-20°C / +50°C) 9V Alkaline Battery Up to 30 Hours
: : : : :
: :
: : :
Loading...