This symbol is intended to alert the user to the
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
ATTENTION : RISQUE DE CHOC ELECTRIQUE
NE PAS QUVRIR
WARNING
To prevent fire or shock hazard, do not expose the unit to rain or moisture.
Caution: To prevent electric shock do not use this (polarized) plug with
Attentions: Pour prévenir les chocs électriques ne pas utiliser cette
presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying the appliance.
an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure.
fiche polarisée avec un prolongateur, une prise de courant on une autre sortie de courant, sauf si les lames peuvent étre insérées à fond sans en laisser aucune partie à découvert. Pour deconnecter completement l’appareil du reseau d’alimentation. deconnecter le cordon d’alimentation de la prise murale. La prise du reseau d’alimentation doit demeurer aisement accessible.
Contents
Contents
Unpacking .......................................................................................................................................4
Installation
Environment....................................................................................................................................4
Important Safety Instructions.............................................................................................................4
Features ...........................................................................................................................................5
Contents and Accessories .............................................................................................................5
Front Panel ......................................................................................................................................6
Rear Panel .......................................................................................................................................8
Applications ...................................................................................................................................11
Block Diagram ..............................................................................................................................12
Specifications ................................................................................................................................13
Service
Procedures....................................................................................................................................15
Schematic.....................................................................................................................................15
Parts List .......................................................................................................................................15
Variations and Options...............................................................................................................15
Warranty .......................................................................................................................................15
*WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g.
near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do not fall and liquids are not spilled into the enclosure through openings.
*CLASS 2 WIRING (Adjacent to speaker terminal): The speaker output of this apparatus can exceed 10 Watts and could be a shock injury.
Connection to speakers should be performed by a skilled person. *Do not install this equipment in a confined space such as a book case or similar unit. *Warning : To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids, such as vases,
should not be placed on this apparatus. *This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
To completely disconnect this apparatus from the AC mains, disconnect the power supply cord plug from the AC receptacle.
* *
The mains plug of the power supply cord shall remain readily accessible.
CAUTION
*These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing
other than that contained in the operating instructions unless you are qualified to do so.
NOTE *This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
Usermanual V1.1 Usermanual V1.1
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
Page 3
4
Unpacking
Unpacking
Although your PN-106/112/224/236/248/260 is neither complicated nor difficult to operate, we recommend you take a few minutes to read this brief manual and familiarize yourself with the important information regarding product features, setup and operation.
As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.
Installation
Installation
DPS-240S/360S/480S/720S DPS-240S/360S/480S/720S
Environment
Never place this product in an environment which could alter its performance or reduce its service life. Such environments usually include high levels of heat, dust, moisture, and vibration.
Features
Features
- HIGH-POWERED, HIGH-CAPACITY 1-CHANNEL CLASS-D POWER AMPLIFIER
High-Power, high performance Class-D Professional Amplifier has up to 240W/360W/480W/720W 1CH power output. * DPS-240S: 240W, DPS-360S: 360W, DPS-480S: 480W, DPS-720S: 720W
- EMERGENCY POWER BACK UP (DC 24V) CAPABILITY
The unit operates on a DC 24V battery power supply for emergency back up without UPS.
- SMPS (SWITCHING MODE POWER SUPPLY) POWER SCHEME
High efficient, light weight SMPS power system is utilized.
- RATED OUTPUT POWER VIA DC BACKUP SUPPLY
Output power can be maintained as AC power when DC 24V power supplied.
- POWERFUL AND DETAILED SOUND QUALITY
High S/N ratio and Low THD reproduces powerful and detailed sound.
- COMPLETE PROTECTION CIRCUITS
Complete circuit protection is activated in case of amplifier overheating, output shorting, overload, over power and DC output.
5
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
S3125A
- OPERATION INDICATOR LED
LED display to check the operating status (AC, STBY, DC, POWER, SIG, -10dB, CLIP, PRT)
- BALANCED INPUT
This connection is used to ensure the lowest noise operation which eliminates the common noise from the cable.
- REMOTE POWER ON/OFF
The remote power allows the amplifier to be turned on or off from a distance or other device via dry contact closure.
- PRIORITY INPUT
PGM is interrupted and over ridden by the Priority input, when a contact closure is received on the Priority input terminal. This is Ideal for Emergency message broadcasting applications.
Contents and Accessories
Contents and Accessories
1. AC power cord x 1EA
2. 3P Terminal Block x 1EA
3. 2P Terminal Block (AC Remote power) x 1EA
4. 8P Terminal Block x 1EA
5. Screw for Rack Mount x 4EA
6. Washer x 4EA
7. Operation manual x 1EA
Usermanual V1.1 Usermanual V1.1
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
Page 4
6
DPS-240S/360S/480S/720S DPS-240S/360S/480S/720S
7
Front Panel
Front Panel
1. AC, STBY, DC LED
When Power switch is on, AC or DC LED will illuminate depending on input Power source. When Power switch is off, STBY LED will turned on. During operation of DC, amplifier is keep going to work even if the switch of power is turned off.
4. AIR VENTS
The air circulation passage to prevent overheating of the device, please do not obstruct the flow as air flows from front to back.
5. POWER SWITCH
Push on/off switch. When Power switch is on, BLUE LED will illuminate.
720S
STBYAC DC
MAX
VOL
MIN
POWER
Power SW Power LED AC LED STBY LED DC LED
SW ON ON ON OFF OFF
AC/DC
SW OFF OFF OFF ON OFF
SW ON ON ON OFF OFF
AC only
SW OFF OFF OFF ON OFF
SW ON ON OFF OFF ON
DC only
SW OFF ON OFF OFF ON
2. OUTPUT LEVEL INDICATOR (1CH, 2CH, 3CH, 4CH)
Indicator display of unit’s output level status. SIG(-30dB) LED: Green, -10dB LED: Green, CLIP LED: Orange, PRT LED: Red
Note: If CLIP LED is lit, sound output is distorted. Reduce the volume level.Note: For the DPS-720S, if the protection circuit is activated and PRT LED is turned on, turn off the power
and turn it on again.
3. VOLUME CONTROL
Volume adjustments are made. Turn clockwise to increase the volume level.
Usermanual V1.1 Usermanual V1.1
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
Page 5
8
984321
657
G
INPUT
}
DPS-240S/360S/480S/720S DPS-240S/360S/480S/720S
9
Rear Panel
Rear Panel
1. AC INPUT
Connect the power cable which is supplied with the unit. Do not bend, pull, twist, heat and cut by force. It may cause electric shock.
AC POWER
REMOTE
OUTPUT
N.C
6. PRIORITY VOLUME CONTROL
It is a volume control of PRIORITY INPUT signal. This control can adjust PRIORITY INPUT signal used as emergency broadcasting. Turn clockwise to turn the signal level and counterclockwise to lower the signal level. It is mainly for priority broadcasting so, don’t make the VOLUME level too low.
7. OUTPUT TERMINAL
PRIORITY
PRIORITY
VOLUME
SW INPUT
+
-
G1
N.C
COM
MIN MAX
CH 1
OUTPUT
PGM INPUT
VOLTAGE
+
-
G
70V100V
Speaker Output Terminal. Before connecting speakers to the unit, be sure to disconnect the AC power cable. Make certain that the total impedance is not less than the rated impedance indicated.
OUTPUT
CH 1
N.C
....
10W 10W 10W 10W
2. DC INPUT
This is emergency DC terminal (DC 24V). When something happens to AC power, DC power automatically operates. Input provides power to the device regardless of power switch. Please check voltage and +, - polarity.
3. AC POWER REMOTE
This terminal allows the amplifier to be turned on or off from a distance or other device.
4. AIR VENTS
Air circulation vents to prevent the device from overheating. Please be careful not to block the front/back of the vents.
5. PRIORITY INPUT AND CONTACT CLOSURE
Each amplifier module has 2 audio inputs. The PGM input and PRIORITY input. PGM input is interrupted and over ridden by the PRIORITY input when a contact closure is received on the PRI select terminal. This is Ideal for Emergency message broadcasting applications. Please refer to the following picture about the suitable cables.
PRIORITY
SW INPUT
N.C
COM
+
-
G1
­+
COM 1
SW
}
Caution:
1. Make sure that the total impedance does not equal or less than the rated impedance.
Speaker Output Speaker Impedance
240W
360W
480W
720W
100V / 41.7Ω
70V / 20.4Ω
100V / 27.8Ω
70V / 13.6Ω
100V / 20.8Ω
70V / 10.2Ω
100V / 13.9Ω
70V / 6.8Ω
2. Do not connects a speaker has lower impedance than rated impedance, it may cause the problem to unit.
3. Do not put the speaker cable close to input signal cable.
8. OUTPUT VOLTAGE SELECTOR SWITCH
This two-position switch is used to select a output voltage. (100V / 70V)
Usermanual V1.1 Usermanual V1.1
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
Page 6
10
+
DPS-S SERIES
SPEAKER
DPS-240S/360S/480S/720S DPS-240S/360S/480S/720S
9. PGM INPUT TERMINAL
Terminal block connector accepts the source input. Please refer to the following picture about the suitable cables.
PGM INPUT
+
-
G
G
-
Applications
Applications
11
IMX-416
AC POWER
REMOTE
PRIORITY SOURCE
DRY CONTACT
OUTPUT
CH 1
N.C
PRIORITY
SW INPUT
N.C
OUTPUT
VOLTAGE
PRIORITY
VOLUME
+
-
G1
COM
MIN MAX
PGM INPUT
+
-
G
70V100V
Usermanual V1.1 Usermanual V1.1
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
Page 7
12
DPS-240S/360S/480S/720S DPS-240S/360S/480S/720S
13
Block Diagram
Block Diagram
DPS-240S/360S/480S DPS-720S
100/70 Vrms
SPEAKER OUTP UT
2nd ORDER LPF
+HV
PWM
Specifications
Specifications
DPS-240S DPS-360S DPS-480S DPS-720S
Rated Output Power 240W 360W 480W 720W
100/70 Vrms
SPEAKER OUTP UT
Output Level/Impedance
100V/41.7Ω 100V/27.8Ω 100V/20.8Ω 100V/13.9Ω
70V/20.4Ω 70V/13.6Ω 70V/10.2Ω 70V/6.8Ω
Input Sensitivity 1V/10kΩ
-HV
+HV
-VA
+VA
MAIN
ST-B Y
PFC
SMPS
DC-DC
RECTIFIER
DC
AC
-HV
SPEAKER RELAY
OCP, OTP
PROTECTION
4th ORDER LPF
+HV
-HV
-HV
+HV
-VA
+VA
THD (AES17, 1/8 Power) Less than 0.5%
S/N (20kHz LPF) Better than 100dB
MAIN
ST-B Y
SMPS
DC-DC
RECTIFIER
DC
AC
Frequency Response (1W, ±3dB) 60Hz~20kHz
Operating Temperature
-10~40
Power Source AC 120V, 60Hz, 220-240V, 50/60Hz, DC 24V
Power Consumption 130W 250W
Weight (Set) 6.9kg/15.2lb 7.9kg/17.4lb
PROTECT M ORE THAN 85℃
FAN START 65℃
FAN CONTROL
TEMPERATURE DETECTION
FAN
OCP, OTP
PROTECTION
PWM
PROTECT M ORE THAN 85℃
FAN START 65℃
FAN CONTROL
TEMPERATURE DETECTION
FAN
Dimensions (Set)
* Design and specification are subject to be changed for the improvement of product quality without pre notice.
482(W) × 88(H) × 371(D)mm
18.9(W) x 3.4(H) x 14.6(D)in
482(W) × 88(H) × 424(D)mm
18.9(W) x 3.4(H) x 16.7(D)in
GAIN=0/-3dB
LPF 35kHz
+12dB
100V/70V SWITCH
SIG(GRN)
CLIP(YEL)
-10dB(GRN)
PGM/PRI TOGGLE
+12dB
PGM VOLUME
0dB
GND
PGM-
PGM+
PGM INPUT
0dB
PRI VOLUM E
P/C
1
COM
GND
PRI-
PRI+
PRI
PRI SELECT
GAIN=0/-3dB
HPF 60Hz
LPF 35kHz
+12dB
100V/70V SWITCH
SIG(GRN)
CLIP(YEL)
-10dB(GRN)
PGM/PRI TOGGLE
+12dB
PGM VOLUME
0dB
GND
PGM-
PGM+
PGM INPUT
0dB
PRI VOLUM E
P/C
1
COM
GND
PRI-
PRI+
PRI
PRI SELECT
Usermanual V1.1 Usermanual V1.1
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
Page 8
14
DPS-240S/360S/480S/720S DPS-240S/360S/480S/720S
15
DIMENSIONS
DPS-240S/360S/480S
440
482
371
Service
Service
Procedures
Take steps to insure the problem is not related to operator error or other products within the system. Information provided in the troubleshooting portion of this manual may help with this process. Once it is certain that the problem is related to the product contact your warranty provider as described in the warranty section of this manual.
Schematic
405
A Schematic is available by contacting your warranty provider.
Parts List
A Parts List is available by contacting your warranty provider.
Variations and Options
Variations and Options
88
DPS-720S
440
482
424
Variations
Products supplied through legitimate sources are compatible with local AC power requirements.
Options
No optional items are available for this product.
Warranty
458
88
Warranty
Warranty terms and conditions vary by country and may not be the same for all products. Terms and conditions of warranty for a given product may be determined first by locating the appropriate country which the product was purchased in, then by locating the product type.
To obtain specific warranty information and available service locations contact Inter-M directly or the authorized Inter-M Distributor for your specific country or region.
Usermanual V1.1 Usermanual V1.1
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
Page 9
DPS-240S/360S/480S/720S
User manual V1.1
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 (0)5 61 31 86 87
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · commercial@majorcom.fr · www.majorcom.fr
Loading...