MAJORCHARGE 24/25, 48/20, 36/20, 12/10, 12/5 Owner's Manual

...
MAJORCHARGE
Battery Charger Owner’s Manual
6/8/12/16/24/36/48 Volt
Standard Features of all Chargers
Battery Type Switch (BTS) High energy return, fast charging Constant current first stage Dual voltage limit (cyclic/standby) Proportional timed cyclic charge stage Constant voltage float standby Automatic safety override timer Start delay on battery connect Short and reverse connector shutdown Rugged SCR phase control Mains zero-crossing battery sensing
AND PROPER USE OF THE CHARGER
***SAVE THESE INSTRUCTIONS***
MajorPower.Com
***CAUTION***
READ THIS MANUAL CAREFULLY
FOR RULES OF SAFE OPERATION
http://www.majorpower.com
12/24/36/48 Volt
DIMENSIONS
12”L x 7”W x 7”H
Model Input Output
MajorCharge12/25 117VAC, 60Hz, 480VA 12VDC, 25A MajorCharge24/25 117VAC, 60Hz, 850VA 24VDC, 25A MajorCharge36/20 117VAC, 60Hz, 1120VA 36VDC, 20A
MajorCharge48/20 117VAC, 60Hz, 1400VA 48VDC, 20A
Suitable for use with all types of lead-acid batteries, including the new types of maintenance-free and gelled electrolyte batteries.
OPTIONAL EXPORT AC INPUT RATINGS
100 V – 50 Hz AC Input (Japan)
115/230 V – 50 Hz AC Input (Europe) (CE)
Full Wave Phase Controlled Rectification
CONTROL
Voltage limited to 2.42 V/Cell (Normal Mode)
2.33 V/Cell (Gel-Cell Mode)
2.62 V/Cell (Liquid Electrolyte Mode)
Current limited to AMP rating MEAN DC
Automatic timer starts when first stage voltage
limit reached. Proportional CV stage timer –t/2+1 hour.
Constant voltage 2.3 V/Cell after timeout, with
temperature compensation.
PROTECTION
Electronic reverse polarity.
Short circuit shutdown and current limit.
Combined circuit breaker and power switch on
front panel.
BATTERY TYPE & RATING
HD Chargers are for use with Lead Acid Batteries of minimum capacity 50 AH, Gel Cell, Absorbed Electrolyte or Liquid Electrolyte types by using the BTS (Battery Type Switch)
12/24 Volt
DIMENSIONS
6”L x 6.5”W x 5.25”H
Model Input Output
MajorCharge12/5 117VAC, 60Hz, 110VA 12VDC, 5A
MajorCharge12/10 117VAC, 60Hz, 220VA 12VDC, 10A
MajorCharge24/5 117VAC, 60Hz, 200VA 24VDC, 5A
MajorCharge24/8 117VAC, 60Hz, 320VA 24VDC, 8A
Suitable for use with all types of lead-acid batteries, including the new types of maintenance-free and gelled electrolyte batteries.
OPTIONAL EXPORT AC INPUT RATINGS
100 V – 50 Hz AC Input (Japan)
115/230 V – 50 Hz AC Input (Europe) (CE)
Full Wave Phase Controlled Rectification
CONTROL
Voltage limited to 2.42 V/Cell (Normal Mode)
2.33 V/Cell (Gel-Cell Mode)
2.62 V/Cell (Liquid Electrolyte Mode)
Current limited to AMP rating MEAN DC
Automatic timer starts when first stage voltage
limit reached. Proportional CV stage timer –t/2+1 hour.
Constant voltage 2.3 V/Cell after timeout, with temperature compensation.
PROTECTION
Electronic reverse polarity.
Short circuit shutdown and current limit.
AC input fuse in AC input connector.
BATTERY TYPE & RATING
PRO Chargers are for use with Lead Acid Batteries, Gel Cell, Absorbed Electrolyte or Liquid Electrolyte types by using the BTS (Battery Type Switch)
MajorPower.Com
http://www.majorpower.com
6/12/24 Volt
DIMENSIONS
6”L x 6.5”W x 5.25”H
Model Input Output
MajorCharge6/6 117VAC, 60Hz 6VDC, 6A MajorCharge12/2 117VAC, 60Hz 12VDC, 2A MajorCharge24/3 117VAC, 60Hz 24VDC, 3A
MajorCharge36/3 117VAC, 60Hz 36VDC, 3A
MajorCharge48/5 117VAC, 60Hz 48VDC, 5A
Suitable for use with all types of lead-acid batteries, including the new types of maintenance-free and gelled electrolyte batteries.
OPTIONAL EXPORT AC INPUT RATINGS
100 V – 50 Hz AC Input (Japan)
115/230 V – 50 Hz AC Input (Europe) (CE)
Full Wave Phase Controlled Rectification
CONTROL
Voltage limited to 2.4 V/Cell
Current limited to AMP rating MEAN DC
Finish voltage 2.3 Volts/Cell
Proportional Timed Cyclic Charge Stage Flashing Yellow LED to show 80% state of charge
PROTECTION
Electronic reverse polarity.
Short circuit shutdown.
Low voltage start.
Optional temperature compensation.
BATTERY TYPE & RATING
GEL Chargers are for use with Lead Acid, Gel Cell Batteries
SAVE THESE INSTRUCTIONS – This manual
1. contains important safety and operating instructions.
2. Before using this battery charger, read all instructions and cautionary markings on (1) the battery charger, (2) the battery, (3) product using the battery.
3. CAUTION – To reduce risk of injury, charge only lead acid, maintenance-free, or flooded lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury or damage.
4. Do not expose charger to rain or snow.
5. Use of an attachment not sold or recommended by the battery charger manufacturer may result in a risk of fire, electric shock or injury to person.
6. To reduce risk of damage to electric plug and cord, pull by plug rather than cord with disconnecting charger.
7. Make sure cord is located so that it will not be stepped on, tripped over or otherwise subjected to damage or stress.
8. An extension cord should not be used unless absolutely necessary. Use of improper extension cord could result in risk of fire and electrical shock. If an extension cord must be used, make sure:
a. That pins on plug of the extension cord are
b. That the extension cord is properly wired
c. That the wire size is large enough for the
Length of cord
AWG Wire Size
9. Do not operate charger with damaged cord or plug. REPLACE THEM IMMEDIATELY.
10. Do not operate charger if it has received a sharp blow, been dropped or otherwise damaged in any way; return it to a qualified service source.
11. Do not disassemble charger if repair or service is required; Incorrect reassembly may result in a risk of electrical shock or fire. Bring charger to a qualified service source.
12. To reduce risk of electrical shock, unplug charger from outlet before attempting any maintenance or cleaning.
the same number, size and shape as those of the plug on the charger.
and in good electrical condition.
A/C ampere rating of the charger as specified in the table below:
25 ft 50 ft 100 ft 100 ft
18 18 16 14
MajorPower.Com
http://www.majorpower.com