Specifications
Courtyard 36
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH VIEWING AREA
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH VIEWING AREA
Actual Framing Actual Framing Actual Framing Actual Framing
Actual Framing Actual Framing Actual Framing Actual Framing
ODCOUG-36
41-3/4"
(1060mm)
43-1/2"
(1105mm)
31-1/2"
(800mm)
43-1/2"
(1105mm)
44"
(1118mm)
44-1/8"
(1121mm)
(457mm)
Courtyard 36
Outdoor Gas Fireplace
18"
18-1/8"
(459mm)
(914mm x 781mm)
36" x 30-3/4"
Back 31-1/2"
36"
41-3/4"
43-1/4"
WITH
(800mm)
(914mm)
(1060mm)
(1099mm)
STANDOFFS
FRONT VIEW
30-3/4"
(781mm)
44"
(1118mm)
44"
(1118mm)
38"
(965mm)
11"
(279mm)
16"
(406mm)
18"
(457mm)
SIDE VIEW
APPLIANCE LOCATIONS
48-1/2"
(1232mm)
3/4"
(19mm)
3/4"
(19mm)
43-1/2"
(1105mm)
70-1/2"
(1791mm)
Additional information can be found online at www.fireplaces.com
18-1/8"
(460mm)
7/8"
(38mm)
Note: If this surface is
inside the building’s
warm air envelope...
43-1/2"
(1105mm)
36" minimum
(914mm)
to combustible
object
...then this surface
must be an exterior
wall system.
7/8"
(22mm)
Specifications
Firebox Opening
18"
(457mm)
20"
(508mm)
22"
(559mm)
24"
(610mm)
36" (914mm)
minimum to
ceiling
FRAMING DIMENSIONS CLEARANCES TO COMBUSTIBLES
allowed in shaded areas
Courtyard 36
Notice: Vinyl siding must not be
placed between the appliance
*36" min.
(914mm)
to ceiling
*Measured from top
of firebox opening
Combustible materials
o
36"
(914mm)
opening and the ceiling/overhang.
44-1/8"
(1121mm)
COMBUSTIBLE MANTEL PROJECTIONS
12"
(305mm)
8"
(203mm)
6"
(152mm)
Ceiling or
Overhang
Non-combustible material
Additional
Structure or
Sidewall
(305mm)
12"
minimum - one side only
Alcove installations require
from each side of the firebox opening.
BUILT-IN INSTALLATION
Control
Mounting Box
With Cover
14" (356mm)
8" (203mm)
min.
Wall Switch
Wires
36"
(914mm)
min.
MOISTURE RESISTANCE
2"
(51mm)
Front View Tape Location Side View of Drainage
2"
(51mm)
2"
(51mm)
Water
Membrane
Water Membrane
below drain
Water
Membrane
Electrical
Wiring Hole
Angle View Water Membrane
PRODUCT LISTING CODES
US ANSI Z21.97-2010
CAN CR97-003
Additional information can be found online at
www.fireplaces.com.
Product information provided is not complete
and is subject to change without notice. Product
installation must adhere strictly to instructions
accompanying product to avoid risk of fire and
potential injury.
A brand of Hearth & Home Technologies Inc.
fireplaces.com | 888-427-3973
ODL/COURTYARD36_0318