Majestic MDVI35IN Installation Manual

Installation Manual
Installation and Appliance Setup
INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
RUBY SERIES
Models: MDVI30IN MDVI35IN MDVI30IL MDVI35IL
WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor’s phone. Follow the gas sup­plier’s instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed by a qualifi ed installer, service agency , or the gas supplier.
This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280 in the United States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s) of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used.
In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fi tter.
See T able of Contents for location of additional Commonwealth of Massachusetts requirements.
Majestic • MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual • 2205-980 Rev. i • 1/17
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
1
Safety Alert Key:
• DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Used to address practices not related to personal injury.
Table of Contents
Installation Standard Work Checklist . . . . . . . . . . . . . . . . . . . . 3
1 Product Specifi c and Important Safety Information
A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
B. Glass Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
C. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 4
E. Non-Combustible Materials Specifi cation. . . . . . . . . . . . . . 4
F. Combustible Materials Specifi cation . . . . . . . . . . . . . . . . . 4
G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Getting Started
A. Design and Installation Considerations . . . . . . . . . . . . . . . 5
B. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . . 5
C. Inspect Appliance and Components . . . . . . . . . . . . . . . . . . 5
3 Framing and Clearances
A. Appliance/Decorative Front Dimension Diagrams . . . . . . . 6
4 Fireplace Size Requirements
A. Minimum Fireplace Opening . . . . . . . . . . . . . . . . . . . . . . . 8
B. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 10
5 Termination Location and Vent Information
A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . 11
8 Electrical Information
A. General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
B. Wiring Requirements - Intellifi reTM Plus Ignition
System Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
C. Optional Accessories Requirements . . . . . . . . . . . . . . . . 19
9 Gas Information
A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
B. Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . 20
E. Air Shutter Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
10 Finishing
A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 22
11 Appliance Setup
A. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
B. Remove the Shipping Materials . . . . . . . . . . . . . . . . . . . . 23
C. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
D. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
E. Place the Lava Rock . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
F. Ember Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
G. Install the Log Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . 25
H. Install Decorative Front/Surround. . . . . . . . . . . . . . . . . . . 31
6 Installation Preparation
A. Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
B. Flue Damper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
C. Gas Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
D. Fireplace Conversion Notice . . . . . . . . . . . . . . . . . . . . . . 12
E. Electrical Outlet Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
F. Remote Control Confi guration . . . . . . . . . . . . . . . . . . . . . 12
7 Installing Vent Pipe and Appliance
A. Vent Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
B. Venting Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
C. Connecting Vent Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
D. Placing, Securing and Leveling the Appliance . . . . . . . . . 15
E. Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
F. Installing Adaptor and Termination Cap . . . . . . . . . . . . . . 16
2
Majestic • MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual • 2205-980 Rev. i • 1/17
12 Reference Materials
A. Vent Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
B. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
= Contains updated information.
Installation Standard Work Checklist
ATTENTION INSTALLER:
Follow this Standard Work Checklist
This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual.
Customer: Lot/Address:
Model (circle one): MDVI30IN MDVI35IN MDVI30IL MDVI35IL
WARNING! Risk of Fire or Explosion! Failure to install appliance according to these instructions could lead to a ¿ re or explosion.
Appliance Install YES IF NO, WHY?
Verify ¿ replace is clean and remove/block open damper/modify damper for vent pipe clearance (Pg. 12) . ___________________________ Appliance is leveled and secured. (Pg. 15) ___________________________
Venting/Chimney Section 7 (Pg. 13-17)
Exhaust stainless steel À ex is properly formed and routed through existing ¿ replace damper. ___________________________ Vent intake and exhaust liners are properly installed to the correct collars, sealed and secured to top plate and to the termination cap. ___________________________ Exterior roof À ashing installed and sealed. ___________________________ Termination cap installed, secured and sealed to top plate. ___________________________
Date Installed: Location of Fireplace: Installer: Dealer/Distributor Phone #
Serial #:
Electrical Section 8 (Pg. 18-19)
Unswitched power (110-120 VAC) provided to the appliance. ___________________________ Switch wires properly installed. ___________________________
Gas Section 9 (Pg. 20-21)
Proper appliance for fuel type. ___________________________ Was a conversion performed? ___________________________ Leak check performed and inlet pressure veri¿ ed. ___________________________ Veri¿ ed proper air shutter setting for installation type. ___________________________
Finishing Section 10 (Pg. 22)
Combustible materials not installed in non-combustible areas. ___________________________ Veri¿ ed all clearances meet installation manual requirements. ___________________________ Mantels and wall projections comply with installation manual requirements. ___________________________
Appliance Setup Section 11 (Pg. 23-31)
All packaging and protective materials removed (inside & outside of appliance). ___________________________ Refractories, logs, media and embers installed correctly. ___________________________ Glass assembly installed and secured. ___________________________ Accessories installed properly. ___________________________ Surround or decorative front properly installed. ___________________________ Manual bag and all of its contents are removed from inside/under the appliance and given to party responsible for use and operation. ___________________________ Fireplace warning plate is attached to the existing woodburning ¿ replace. ___________________________ Remote control is programmed, functions veri¿ ed using remote control ___________________________ instructions. Started appliance and veri¿ ed no gas leaks exist. ___________________________
Hearth & Home Technologies recommends the following:
• Photographing the installation and copying this checklist for your ¿ le.
• That this checklist remain visible at all times on the appliance until the installation is complete. Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective
action needed _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)
Î = Contains updated information.
2205-982 Rev. B 11/16
Majestic • MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual • 2205-980 Rev. i • 1/17
3
1
1
Product Specifi c and Important Safety Information
A. Appliance Certifi cation
MODELS: MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Heater STANDARD: ANSI Z21.88-2014 CSA 2.33-2014
This product is listed to ANSI standards for “Vented Gas Fireplace Heaters” and applicable sections of “Gas Burn­ing Heating Appliances for Manufactured Homes and Recreational Vehicles”, and “Gas Fired Appliances for Use at High Altitudes”.
Majestic gas inserts are designed for installations into solid fuel masonry or factory built fi replaces that have been in- stalled in accordance with the National, Provincial, State and local building codes. Fireplaces are to be constructed of non-combustible materials and, in the absence of local or regional codes, meet criteria of NFP A 21 1. No additional outside air source is required.
NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.
NOT INTENDED FOR USE AS A PRIMAR Y HEAT SOURCE.
This appliance is tested and approved as either supplemen­tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.
B. Glass Specifi cations
This appliance is equipped with 5 mm ceramic glass. Re­place glass only with 5 mm ceramic glass. Please contact your dealer for replacement glass.
C. BTU Specifi cations
Models
(U.S. or Canada)
MDVI30IN (NG)
MDVI30IL (LP)
MDVI35IN (NG)
MDVI35IL (LP)
US
(0-2000 FT)
CANADA
(2000-4500 FT)
US
(0-2000 FT)
CANADA
(2000-4500 FT)
US
(0-2000 FT)
CANADA
(2000-4500 FT)
US
(0-2000 FT)
CANADA
(2000-4500 FT)
Maximum
Input
BTU/h
30,500 17,000 #36
28,000 15,000 #37
27,500 14,500 #52
25,000 13,000 #53
35,000 19,500 #33
32,500 17,500 #34
31,500 16,500 #51
27,500 15,000 #52
Minimum
Input
BTU/h
Orifi ce
Size
(DMS)
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet.
• In CANADA: Reduce input rate 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.
Check with your local gas utility to determine proper orifi ce size.
E. Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC shall be considered
non-combustible materials.
F. Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed pa­per, plant fi bers, plastics, or other material that can ignite and burn, whether fl ame proofed or not, or plastered or unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA C22.1.
• A 110-120 VAC circuit for this product must be pro-
tected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.
4
Majestic • MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual • 2205-980 Rev. i • 1/17
2
2
Getting Started
A. Design and Installation Considerations
Majestic gas inserts are designed for installations into solid fuel masonry or UL127 listed factory built fi replaces. No additional outside air source is required.
Installation MUST comply with local, regional, state and na­tional codes and regulations. Consult insurance carrier, local building inspector, fi re offi cials or authorities having jurisdic- tion over restrictions, installation inspection and permits.
Prior to installing the gas insert:
• Ensure chimney is constructed of non-combustible materials.
• Ensure chimney is clean and in good working order.
• Ensure that all chimney cleanouts fi t properly to prevent air leakage into chimney.
• Ensure combustible mantel and surround clearances comply with insert requirements.
• Ensure all joints are properly engaged and the chimney is properly secured.
• Determine minimum fi replace size. See Section 4.A.
• Determine gas supply piping requirements.
• Determine electrical wiring requirements.
• Determine fi nishing details.
• Determine whether optional accessories—devices such as a wall switch or remote control—are desired.
Installation and service of this appliance should be performed by qualifi ed personnel. Hearth & Home Technologies recommends NFI certifi ed professionals.
B. Tools and Supplies Needed
Before beginning the installation be sure that the following tools and building supplies are available.
Tape measure Pliers Hammer Phillips screwdriver Voltmeter Electric drill and bits (1/4 in.) Gloves Safety glasses Level Reciprocating saw Manometer Flat blade screwdriver Noncorrosive leak check solution 1/2 - 3/4 inch length, #6 or #8 Self-drilling screws
Caulking material (300ºF minimum continuous exposure rating)
C. Inspect Appliance and Components
• Carefully remove the appliance and components from the packaging.
• The vent system components and decorative doors and fronts may be shipped in separate packages.
• If packaged separately, the log set and appliance grate must be installed.
• Report to your dealer any parts damaged in shipment, particularly the condition of the glass.
Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the installation to ensure maximum safety and benefi t.
WARNING! Risk of Fire or Explosion! Damaged parts could impair safe operation. DO NOT install damaged, in- complete or substitute components. Keep appliance dry.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualifi ed service technician, service agency or your dealer.
Majestic • MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual • 2205-980 Rev. i • 1/17
Hearth & Home T echnologies disclaims any responsibility for , and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent
system component.
• Modifi cation of the appliance or vent system.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a fi re hazard.
WARNING! Risk of Fire, Explosion or Electric Shock! DO NOT use this appliance if any part has been under
water. Call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water.
5
3
3
Framing and Clearances
A. Appliance/Decorative Front Dimension Diagrams
Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 4.
A
H
Q
R
T
O
P
B
C
S
G
F
E
J
GAS LINE ACCESS
L
Location
A 23-7/16 595 20-3/16 513 B 34-5/8 879 30-5/8 778 C 31-5/8 803 27-1/2 699 D 15-11/16 398 12-3/16 310 E 24-1/16 611 20-7/16 519 F 21-1/8 537 17-5/8 448
G* 15-11/16 398 14-5/8 371
H 11-3/4 298 10-1/16 256
I 20-7/16 519 17 432
J 1-3/4 44 1-3/4 44
K
MODEL DIMENSIONS
MDVI35IN/IL MDVI30IN/IL
Inches Millimeters Inches Millimeters
D
U
ELECTRICAL ACCESS
MODEL DIMENSIONS
Location
K 4-13/16 122 4-13/16 122
L 10-1/16 256 9-1/8 232 M 2-7/16 62 2-7/16 62 N 5 127 4-1/16 103 O 5-1/8 130 5-1/8 130 P 8-15/16 227 8-15/16 227 Q 1-13/16 46 1-15/16 49 R 3-1/4 83 3-1/4 83 S 5-5/16 135 4-15/16 125
T 10-5/8 270 9-1/2 241 U 4-11/16 119 4-5/8 117
MDVI35IN/IL MDVI30IN/IL
Inches Millimeters Inches Millimeters
I
M
N
*Note: Location G on Figure 14.1 is measuring the appliance depth, for installation depth reference Location G on Figure 5.2.
Figure 3.1 Appliance Dimensions
6
Majestic • MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual • 2205-980 Rev. i • 1/17
DECORATIVE FRONTS CRDI30BK CFCRDI30BK CRDI30BZ CFCRDI30BZ CRDI35BK CFCRDI35BK CRDI35BZ CFCRDI35BZ
D A
E
MDVI30IN/IL
MDVI35IN/IL
F
G
CRDI30BK
CRDI30BZ CFCRDI30BK CFCRDI30BZ
CRDI35BK
CRDI35BZ CFCRDI35BK CFCRDI35BZ
B
C
ABCD EFG
in. 29 13-13/16 4-1/2 36 23-1/2 23 1/2
mm 737 351 114 914 597 584 13
in. 31 15-13/16 4-1/2 37-15/16 25-1/2 25 1/2
mm 787 402 114 964 648 635 13
Figure 3.2 Decorative Front Dimensions - CRDI30BK, CRDI30BZ, CRDI35BK, CRDI35BZ
Majestic • MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual • 2205-980 Rev. i • 1/17
7
4
4
Fireplace Size Requirements
A. Minimum Fireplace Opening
Minimum fi replace opening requirements for a standard 3/4 inch deep surround are shown in Figure 4.2. For smaller openings, an optional 1-1/2 inch deep surround is available and dimensions are shown in Figure 4.3.
WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat­ed out of traffi c and away from furniture and draperies.
• The fi rebrick (refractory), glass doors, screen rails, screen mesh and log grates can be removed from a factory built fi rebox in order to gain minimum gas insert opening requirements.
• Any smoke shelves, shields and baffl es may be removed from the factory built fi rebox if attached with mechanical fasteners.
SIDE VIEW
9 IN.
• The metal fl oor of the solid fuel fi rebox may be removed to facilitate the installation of the insert.
• Cutting of any sheet metal parts of the fi replace in which the gas fi replace insert is to be installed is prohibited, except the fl oor as tested for and as noted above and in Figure 4.1.
• A minimum 1/2 inch gap from the bottom of the appliance to the metal fl oor of the solid fuel fi rebox is RECOMMENDED for optimal fan performance. See side view in Figure 4.1
TOP VIEW
METAL FLOOR OF EXISTING
SOLID FUEL FIREBOX
1/2 IN. MINIMUM LEVELING HEIGHT
(RECOMMENDED) 1/4 IN. REQUIRED
METAL FLOOR OF EXISTING SOLID FUEL FIREBOX
9 IN.
Figure 4.1-A
Figure 4.1-B
• The appliance may not be placed directly on the base of the outer wrap, a 1/4 inch airspace MUST be provided between the insert and the fl oor of the outer wrap. Use the leveling legs to raise the insert a minimum of 1/4 inch. The original fi replace may never be returned to solid fuel in this condition. The sidewalls and top structure of the fi rebox may not be altered with the exception of removable baffl es and dampers.
5 IN.
3 IN.
6 IN.
REMOVE THIS SECTION OF METAL FLOOR
FACTORY BUILT FIREBOX
METAL INSERT
5 IN.
3 IN.
REMOVE THIS SECTION OF METAL FLOOR
6 IN.
• If a minimum 1/2 inch gap can not be achieved, a section of the factory-built metal fl oor can be removed. See Figure 4.1-B.
8
Majestic • MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual • 2205-980 Rev. i • 1/17
TOP VIEW
FRONT VIEW SIDE VIEW
A
C
E
F
B
MINIMUM FIREBOX OPENING
MDVI35IN/IL MDVI30IN/IL
Location
Inches Millimeters Inches Millimeters
A Rear Width 24 610 20-3/4 527
B Front Width 35-1/8 892 31-1/8 791 C Height-Front 24-3/8 619 20-3/4 527 D Height-Rear 21-1/8 537 17-5/8 448
E** Unit Depth 16 406 14-7/8 378
F Venting Depth 10-5/8 270 9-1/2 241
D
Note: Dimensions assume 1/4 inch clearance on all sides. Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum
replace height for bends in vent pipe.
**Unit depth is measured to the back of the surround to give the depth needed for installation. In addition to these dimensions, also reference Clearances and Mantel Projections (Section 4.B).
Figure 4.2 Firebox Opening - Standard Surround
Majestic • MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual • 2205-980 Rev. i • 1/17
9
SIDE VIEW
TOP VIEW
1-1/2 IN.
B
D
A
D
C
D
SURROUND
APPLIANCE
APPLIANCESURROUND
MINIMUM FIREBOX OPENING
MDVI35IN/IL MDVI30IN/IL
Location
Inches Millimeters Inches Millimeters
A
Alternate Unit Width 33-1/2 851 29-1/2 749
D
B
Alternate Unit Depth 15-1/8 384 14 356
D
C
Alternate Unit Height 23 584 19-3/8 492
D
Note: Dimensions assume 1/4 inch clearance on all sides. Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum
replace height for bends in vent pipe.
Figure 4.3 Firebox Opening - Deep Surround
B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear­ances to combustibles as specifi ed. Framing or fi nishing material closer than the minimums listed must be construct­ed entirely of noncombustible materials (i.e., steel studs, concrete board, etc).
Clearance to combustible material under the insert is 1/4 inch (6 mm). Clearance from top of fi replace opening for combustibles extending 12 inches max. is 12 inches.
• Use leveling legs to raise insert minimum 1/4 inch (6 mm) above combustible material or outer wrap of factory built rebox.
Combustible facings must not extend behind the insert surround. For non-combustible material specifi cations refer to Section 1.E.
EXISTING NON-COMBUSTIBLE FACING
12 IN. MAX.
2 IN. MAX.
10 IN. MIN.
12 IN. MIN.
10
Figure 4.4 Mantel Clearances
Majestic • MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual • 2205-980 Rev. i • 1/17