Majestic MARQ42IN Specifications

Specifications
A
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
MARQUIS II 42
Direct Vent Gas Fireplace
design layout decision.
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH GLASS SIZE
Actual Framing Actual Framing Actual Framing Actual Framing
MARQ42IN
62-5/8"
[1591]
61"
[1549]
67"
[1702]
65-9/16"
[1665]
65-5/16"
[1659]
65-9/16"
[1665]
24"
[610]
24"
[610]
41-7/8" x 36-1/16"
[1064 X 916]
TOP VIEW
MARQ42IN
FRONT VIEWLEFT SIDE RIGHT SIDE
DECORATIVE FRONT
Specifications
"
65-9/16" [1665]
78-9/16" [1995]
78-9/16
Notes: Measurements in inches. Measurement is taken from bottom of appliance.
Do not pack with insulation
*Shows center of vent framing hole with
MARQ42IN
APPLIANCE LOCATION
WALL PENETRATION
MANTEL LEG/WALL PROJECTIONS
Factory-supplied non-combustible
COMBUSTIBLE MANTEL PROJECTIONS
Measure ment from fireplace opening to bottom of appliance: = 35-3/16" HEIR36 = 40-3/16" HEIR42
28-5/8"
[727]
28-5/8"
[727]
"
[1995]
23-1/2"
[597]
10"
79-3/16"*
7" min
Fireplace
14" min
opening
board
Combustible or
non-combustible wall
Non-combustible Mantel
HEIR42
65-9/16"
[1665]
111-1/16"
[2821]
or other material.
12"
1/2" Building material
Combustible
column
1/2" Non-combustible material
HEIR36
FIREPLACE OPENING
65-9/16"
[1665]
23-1/2"
[597]
32-13/16"
[833]
78-3/16"
minimum vertical for top venting. Center of hole is 1" above center of horizontal vent pipe. * Add height for chase deeper than 24".
Combustible Mantel
4" maximum
1/2" Building material
Non-combustible
column
6" maximum
Combustible or
non-combustible wall
Combustible mantel
Fireplace
opening
Factory-supplied non-combustible
board
MAX.
9
6
3
1
57
54
51
12
60
See section 13.E for required clearances
14" min
63
MIN.
projections shown. See install manual for non-combustible mantel allowance.
32-13/16
[833]
FRAMING DIMENSIONS
10"
[254]
61"
[1549]
24"
[610]
65-9/16" [1665]
CLEARANCES TO COMBUSTIBLES
0"
Note: A 12" non-combustible hearth extension is required. The replace may be raised from the oor a minimum of 3" to eliminate this requirement. See installation manual for more details.
See install
manual
section 3.D
36"
[914]
[25]
1"
NON-COMBUSTIBLE ZONE
2" X 4" OR GREATER FRAMING MATERIAL
1/2" BUILDING MATERIAL
(MAY BE COMBUSTIBLE)
NO COMBUSTIBLES
IN HATCHED AREA
2" X 4" ONLY IN GRAY AREA
2" X 4" HEADER
CONFIGURATION
FACTORY-SUPPLIED
1/2"
NON-COMBUSTIBLE
BOARD
NOTE:
1"
PIPE IS FOR VISUAL
REFERENCE ONLY
= COMBUSTIBLES
NOT ALLOWED
Product information provided is not complete and is subject to change without notice.
39"
Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
52"
[1321] from appliance
opening to ceiling
92-3/16" [2342] from bottom of fireplace to ceiling
1"
[25]
PRODUCT LISTING CODES
US ANSI Z21.88-2009
CAN CSA 2.33-2009
UL307B
(800) 927-6841 • www.majesticproducts.com
MAJ/MARQUISII_MARQ42IN_0916