Majestic MARQ42 Specifications Sheet

Page 1
Specifications
A
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
MARQUIS II 42
MARQUIS II 4 2
Direct Vent Gas Fireplace
Direct Vent Gas Fireplace
design layout decision.
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH GLASS SIZE
MARQ42
54,500 BTU (NG)
47,500 BTU (LP)
ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING
62-5/8"
[1591]
61"
[1549]
67"
[1702]
65-9/16"
[1665]
65-5/16"
[1659]
65-9/16"
[1665]
24"
[610]
24"
[610]
41-7/8" x 36-1/16"
TOP VIEW
MARQ42IN
MARQ42
[1064 X 916]
FRONT VIEWLEFT SIDE RIGHT SIDE
DECORATIVE FRONT
Page 2
Specifications
"
65-9/16" [1665]
78-9/16" [1995]
78-9/16
Notes: Measurements in inches. Measurement is taken from bottom of appliance.
Do not pack with insulation
*Shows center of vent framing hole with
MARQ42
APPLIANCE LOCATION
WALL PENETRATION
MANTEL LEG/WALL PROJECTIONS
Factory-supplied non-combustible
COMBUSTIBLE MANTEL PROJECTIONS
Measure ment from fireplace opening to bottom of appliance: = 35-3/16" HEIR36 = 40-3/16" HEIR42
28-5/8"
[727]
28-5/8"
[727]
"
[1995]
23-1/2"
[597]
10"
79-3/16"*
7" min
Fireplace
14" min
opening
board
Combustible or
non-combustible wall
Non-combustible Mantel
HEIR36
HEIR42
65-9/16"
[1665]
111-1/16"
[2821]
or other material.
12"
1/2" Building material
Combustible
column
4" maximum
1/2" Non-combustible material
FIREPLACE
OPENING
32-13/16
23-1/2"
[597]
[833]
32-13/16"
[833]
65-9/16"
[1665]
78-3/16"
minimum vertical for top venting. Center of hole is 1" above center of horizontal vent pipe. * Add height for chase deeper than 24".
Combustible Mantel
1/2" Building material
Non-combustible
column
6" maximum
Combustible or
non-combustible wall
Combustible mantel projections shown.
Fireplace
opening
Factory-supplied non-combustible
board
MAX.
9
6
3
1
57
54
51
12
60
See section 13.E for required clearances
14" min
63
MIN.
See install manual for non-combustible mantel allowance.
FRAMING DIMENSIONS
10"
[254]
61"
[1549]
24"
[610]
65-9/16" [1665]
CLEARANCES TO COMBUSTIBLES
0"
Note: A 12" non-combustible hearth extension is required. The replace may be raised from the oor a minimum of 3" to eliminate this requirement. See installation manual for more details.
See install
manual
section 3.D
36"
[914]
[25]
1"
NON-COMBUSTIBLE ZONE
PRODUCT LISTING CODES
US ANSI Z21.88-2009
CAN CSA 2.33-2009
Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
1/2" BUILDING MATERIAL
(MAY BE COMBUSTIBLE)
NO COMBUSTIBLES
IN HATCHED AREA
2" X 4" ONLY IN GRAY AREA
2" X 4" HEADER
CONFIGURATION
FACTORY-SUPPLIED
1/2"
NON-COMBUSTIBLE
BOARD
NOTE:
1"
2" X 4" OR GREATER FRAMING MATERIAL
PIPE IS FOR VISUAL
REFERENCE ONLY
= COMBUSTIBLES
NOT ALLOWED
39"
52"
[1321] from appliance
opening to ceiling
92-3/16" [2342] from bottom of fireplace to ceiling
1"
[25]
UL307B
Majestic — A Brand of Hearth & Home Technologies
7571 215th Street West | Lakeville, MN 55044 877-486-9123 | majesticproducts.com
MAJ/MARQUISII_MARQ42IN_1118