Specifications
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
MARQUIS II 36
Direct Vent Gas Fireplace
design layout decision.
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH GLASS SIZE
MARQ36IN
Actual Framing Actual Framing Actual Framing Actual Framing
57-5/8"
[1464]
56"
[1422]
61"
[1549]
59-1/2"
[1511]
59-1/4"
[1505]
59-1/2"
[1511]
24"
[610]
24"
[610]
35-7/8" x 31-1/16"
[911 X 789]
TOP VIEW
59-1/4" [1505]
29-5/8"
[752]
16"
[406]
MARQ36IN
Heat-Zone
Port
Gas
Access
2-3/4"
[70]
16-1/8"
[410]
FRONT VIEWLEFT SIDE RIGHT SIDE
24"
[610]
®
Electrical
Access
31-1/16"
[789]
3-7/8"
[98]
10-7/8"
[276]
61" [1549]
40-11/16" [1035]
57-5/8"
[1464]
54-15/16"
[1395]
23-1/2"
[597]
Heat-Zone
®
Port
41-3/8"
[1051]
DECORATIVE FRONT
40-11/16"
[1035 mm]
3-5/8"
[92 mm]
35-9/16"
[903 mm]
1-5/16"
[33 mm]
36-13/16"
[935 mm]
Specifications
*Shows center of vent framing hole with
MARQ36IN
APPLIANCE LOCATION
26-1/2"
[673]
26-1/2"
[673]
[597]
59-1/2"
[1511]
105"
[2667]
29-3/4"
[756]
59-1/2"
[1511]
[1886]
"
23-1/2"
WALL PENETRATION
Do not pack with insulation
or other material.
10"
12"
73-3/16"
"*
minimum vertical for top venting.
Center of hole is 1" above center of
horizontal vent pipe.
*Add height for chase deeper than 24".
MANTEL LEG/WALL PROJECTIONS
Combustible Mantel
1/2" Building material
Combustible
column
Fireplace
opening
Factory-supplied
non-combustible
board
Combustible or
non-combustible wall
Non-combustible Mantel
7" min
14" min
4" maximum
Factory-supplied
non-combustible
board
Fireplace
opening
Non-combustible
column
See section 13.E
for required
clearances
14" min
1/2" Building material
MANTEL PROJECTIONS
1/2 IN NON-COMBUSTIBLE MATERIAL
FIREPLACE
OPENING
MAX.
12
9
6
3
1
55
52
49
46
Note: All measurements in
inches.
58
Note: Measurement is taken
from bottom of appliance.
MIN.
Note: Measurement from
fireplace opening to bottom
of appliance is 35-3/16".
29-3/4
23-1/2"
[597]
6" maximum
Combustible or
non-combustible wall
[756]
FRAMING DIMENSIONS
10"
[254]
56"
[1422]
24"
59-1/2" [1511]
[610]
CLEARANCES TO COMBUSTIBLES
0"
Note: A 12" non-combustible
hearth extension is required.
The replace may be raised
from the oor a minimum of
3" to eliminate this
requirement. See installation
manual for more details.
See
install manual
section 3.D
36"
[914]
[25]
1"
NON-COMBUSTIBLE ZONE
2" x 4" OR GREATER
FRAMING MATERIAL
1/2" BUILDING MATERIAL
(MAY BE COMBUSTIBLE)
NO COMBUSTIBLES
IN HATCHED AREA
2" x 4" ONLY IN
GRAY AREA
2" x 4" HEADER
CONFIGURATION
FACTORY-SUPPLIED
1/2"
NON-COMBUSTIBLE
BOARD
NOTE:
1"
PIPE IS FOR VISUAL
REFERENCE ONLY
Product information provided
is not complete and is subject
to change without notice.
39"
Product installation must
adhere strictly to instructions
accompanying product to
avoid risk of fire and potential
injury.
52"
[1321]
from appliance
opening to
ceiling
87-3/16" [2215]
from bottom of
1"
[25]
PRODUCT LISTING CODES
US ANSI Z21.88-2009
CAN CSA 2.33-2009
UL307B
Combustible Mantel
Projections shown.
See installation manual for
Non-combustible Mantel
Projections
(800) 927-6841 • www.majesticproducts.com
= COMBUSTIBLES
NOT ALLOWED
MAJ/MARQUISII_MARQ36IN_0917