MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH GLASS SIZE
MARQ36IN
Actual Framing Actual Framing Actual Framing Actual Framing
57-5/8"
[1464]
56"
[1422]
61"
[1549]
59-1/2"
[1511]
59-1/4"
[1505]
59-1/2"
[1511]
24"
[610]
24"
[610]
35-7/8" x 31-1/16"
[911 X 789]
TOP VIEW
59-1/4" [1505]
29-5/8"
[752]
16"
[406]
MARQ36IN
Heat-Zone
Port
Gas
Access
2-3/4"
[70]
16-1/8"
[410]
FRONT VIEWLEFT SIDE RIGHT SIDE
24"
[610]
®
Electrical
Access
31-1/16"
[789]
3-7/8"
[98]
10-7/8"
[276]
40-11/16" [1035]
57-5/8"
[1464]
54-15/16"
[1395]
23-1/2"
[597]
Heat-Zone
®
Port
41-3/8"
[1051]
DECORATIVE FRONT
40-11/16" [1035 mm]
3-5/8" [92 mm]
35-9/16" [903 mm]
1-5/16" [33 mm]
36-13/16" [935 mm]
Specifications
"
59-1/2" [1511]
74-1/4" [1886]
74-1/4
74-3/16
*Shows center of vent framing hole with
fireplace to ceiling
MARQ36IN
APPLIANCE LOCATION
26-1/2"
[673]
26-1/2"
[673]
[597]
59-1/2"
[1511]
105"
[2667]
29-3/4"
[756]
59-1/2"
[1511]
[1886]
"
23-1/2"
WALL PENETRATION
Do not pack with insulation or other material.
10"
12"
73-3/16"
"*
minimum vertical for top venting. Center of hole is 1" above center of horizontal vent pipe. *Add height for chase deeper than 24".
MANTEL LEG/WALL PROJECTIONS
Combustible Mantel
1/2" Building material
Combustible
column
Fireplace
opening
Factory-supplied non-combustible
board
Combustible or
non-combustible wall
Non-combustible Mantel
7" min
14" min
4" maximum
Factory-supplied non-combustible
board
Fireplace
opening
Non-combustible
column
See section 13.E for required clearances
14" min
1/2" Building material
MANTEL PROJECTIONS
1/2 IN NON-COMBUSTIBLE MATERIAL
FIREPLACE OPENING
MAX.
12
9
6
3
1
55
52
49
46
Note: All measurements in inches.
58
Note: Measurement is taken from bottom of appliance.
MIN.
Note: Measurement from fireplace opening to bottom of appliance is 35-3/16".
29-3/4
23-1/2"
[597]
6" maximum
Combustible or
non-combustible wall
[756]
FRAMING DIMENSIONS
10"
[254]
56"
[1422]
24"
59-1/2" [1511]
[610]
CLEARANCES TO COMBUSTIBLES
0"
Note: A 12" non-combustible hearth extension is required. The replace may be raised from the oor a minimum of 3" to eliminate this requirement. See installation manual for more details.
See
install manual
section 3.D
36"
[914]
[25]
1"
NON-COMBUSTIBLE ZONE
2" x 4" OR GREATER FRAMING MATERIAL
1/2" BUILDING MATERIAL
(MAY BE COMBUSTIBLE)
NO COMBUSTIBLES
IN HATCHED AREA
2" x 4" ONLY IN GRAY AREA
2" x 4" HEADER
CONFIGURATION
FACTORY-SUPPLIED
1/2"
NON-COMBUSTIBLE
BOARD
NOTE:
1"
PIPE IS FOR VISUAL
REFERENCE ONLY
Product information provided is not complete and is subject to change without notice.
39"
Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
52"
[1321] from appliance
opening to ceiling
87-3/16" [2215] from bottom of
1"
[25]
PRODUCT LISTING CODES
US ANSI Z21.88-2009
CAN CSA 2.33-2009
UL307B
Combustible Mantel Projections shown. See installation manual for Non-combustible Mantel Projections
(800) 927-6841 • www.majesticproducts.com
= COMBUSTIBLES
NOT ALLOWED
MAJ/MARQUISII_MARQ36IN_0917
Loading...