Majestic LDS46 Installation Manual

TM
1
TM
Instructions
Models: LDS33, LDS46 Decorative Shroud
These decorative shrouds have been tested for use with specifi c Hearth & Home Technologies Inc. fi replaces. Check with your local building code agency before you begin installation to ensure compliance with local codes, including the need for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need clarifi cation of any of the instructions contained here, contact your Hearth & Home Technologies Inc. dealer. For the dealer nearest you, please visit www.hearthnhome.com.
Note: An arrow (¨) found in the text signifi es change in content.
CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses
during installation. Sheet metal edges are sharp.
LDS33/LDS46 Installation Around Woodburning Termination Caps
1
The TS Series or TR Series termination caps (see Figures 1-3) are designed to be installed on an exterior chase with a decorative chimney shroud or a purchased LDS33/LDS46 decorative shroud.
13 1/4 in.
(337 mm)
16 1/4 in.
(413 mm)
26 1/2 in.
(673 mm)
28 1/2 in.
(724 mm)
Figure 2 TR342 & TR11T
18 in.
(457 mm)
Figure 1 TS345 Square Termination Cap
34-3/4 in. (883 mm)
32-1/2 in. (826 mm)
15-3/4 in. (400 mm)
Figure 2 TR342 & TR11T
Hearth & Home Technologies Inc. • LDS33/LDS46 Decorative Shrouds • 31173 • Rev E • 04/09
1
WARNING! Risk of Fire!
You must maintain clearances to
avoid overheating the chase structure.
The TR Series cap must be raised to the minimum dimensions (or greater) above the shroud as shown in Figure 6.
A. Make sure the shroud will meet or exceed the minimum requirements for the termination cap you are going
to install as shown in Figures 4-6.
16 in. (406 mm)
Minimum
Open
Top
Only
Maximum Height of 14 1/2 in. (368 mm)
3 in. (76 mm) air
space from bottom
of shroud to top of
chase
Figure 4 Minimum Dimensions of Shroud & Chase for TS345
19 in. (483 mm)
Minimum
Field
Constructed
Shroud
Roof
Chase
Wire
Mesh
Radiation
Shield
Maximum Height
of 14 1/2 in.
(368 mm)
3 in. (76 mm) air space from bottom of shroud to top of chase.
Figure 5 Minimum Dimensions of Shroud & Chase for TR Series Termi-
nation Caps
Wire
Mesh
28 in. (711 mm)
Minimum
25 in. (635 mm
Minimum
Roof
Chase
25 in. (635 mm)
(TR344/TR11)
Maximum Height
14 1/2 in. (368 mm)
Shroud
Minimum
(SHROUD)
Flue
Leg
Chase
(CHASE)
Top
28 in. (711 mm)
Minimum
Figure 5 Shroud & TR Series cap with no Radiation Shield
6" Min.
Above the
Shroud.
Storm Collar
Shroud
Leg
3 in (76 mm) air space from bottom of shroud to top of chase.
2
Hearth & Home Technologies Inc. • LDS33/LDS46 Decorative Shrouds • 31173 • Rev E • 04/09
B. Determine if the legs will be secured to the side or the top of the chase. See Figures 7 and 8. Figures 9 and
10 illustrate how to prepare the legs for mounting the shroud to the chase top.
Figure 7 Secure the Legs - Side of Chase Top Figure 8 Secure the Legs - Top of Chase
Figure 9 Cut Legs to Size Figure 10 Bend Legs to Size
Hearth & Home Technologies Inc. • LDS33/LDS46 Decorative Shrouds • 31173 • Rev E • 04/09