Majestic ECHEL72IN Specifications

Specifications
ECHEL72IN
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH VIEWING AREA
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
Actual Framing Actual Framing Actual Framing Actual Framing
ECHEL72IN
Actual Framing Actual Framing Actual Framing Actual Framing
82" 84-1/4" 82" 84-1/4" 47-3/4" 48" 17-1/8" 18-1/4"
72" Direct Vent Gas Fireplace
71-1/2" x 12-1/2"
30-1/2"
[775]
23-3/4" [603]
2-3/4" [70]
8-9/16" [217]
47-3/4" [1213]
2-3/8" [60]
18-5/8"
[473]
24-1/2"
[622]
8-7/8" [225]
17-1/8" [435]
7-1/4" [184]
GAS ACCESS
82" [2083]
J
Top
86" [2184]
75-1/8" [1908]
1" [25]
8-9/16" [217]
o
8" [203]
CENTERED ON APPLIANCE
ELECTRICAL ACCESS
15-5/8"
[397]
48-1/2" [1232]
4" [102]
8-9/16"
[217]
75"
[1905]
5/8" [16]
25"
[635]
24"
[610]
Additional information can be found online at www.majesticproducts.com
FrontLeft Right
75 [1905]
13-1/8"
[333]
16-3/4"
[425]
73-3/16" [1859] 76-5/16" [1938]
CFT Front
Specifications
MEASUREMENT FROM TOP EDGE OPENING
24
27
30
31
TO CEILING
9
6
3
Measurement from top edge opening to bottom of appliance =24-1/2"
MAX.
Note:
All measurements in inches.
Specifications
35-1/4"
Acceptable on both sides of opening
31" [787]
0" [0]
0" [0]
55-1/2" [1410]
48" [1219]
1" [25]
1" [25]
Header depth not to exceed 3-1/2" [89]
Adjust framing dimensions for interior sheathing (such as Sheetrock).
If appliance is installed o of oor, maintain required clearances to combustibles. Construct platform in accordance with local building codes.
10" [254]
48"
[1219]
18-1/4"
[464]
84-1/4" [2140]
31" [787]
0" [0]
0" [0]
55-1/2" [1410]
48" [1219]
1" [25]
1" [25]
ECHEL72IN
APPLIANCE LOCATION
1"
[895]
[25]
1"
88"
[25]
[2235]
84-1/4
[2140]**
1124-3/8"
[3159]
Refer to Section 10 of install manual for hearth, mantel and wall projection information.
If a Heat-Zone refer to
Section 5.E of install manual for information.
2 HEAT-ZONES = Add 4" to ** dimension 1 HEAT-ZONE = Add 2" to ** dimension
84-1/4 [2140]**
WALL PENETRATION
Do not pack with insulation or other material.
10"
75"*
[1905]
84-1/4 [2140]**
®
or Heat-Duct will be installed,
18-1/4"
[464]
12"
74"
[1880]
* Shows center of vent framing hole for top venting. Center of hole is 1" [25] above center of horizontal vent pipe.
See clearances
in install manual
84-1/4 [2140]**
FRAMING DIMENSION
CLEARANCES TO COMBUSTIBLES
MANTEL PROJECTIONS - COMBUSTIBLE
MANTEL PROJECTIONS - NON-COMBUSTIBLE
Note: All measurements in inches.
MAX.
1
TO CEILING
13-16
6
5
4
3
2
6
MEASUREMENTS FROM TOP ED GE OF THE APPLIANCE OPENING
Measurement from top edg e of opening to bottom of appliance = 2 4-1/2"
18
11
10
9
8
7
OVERLAP FIT
31
MIN.
Note: All measurements in inches.
INSIDE FIT
MAX.
14-16
7
6
5
10
9
4
MEASUREMENTS FROM TOP E DGE OF THE APPLIANCE OPENI NG
Measurement from top edge of opening to bottom of applianc e = 24-1/2"
MANTEL LEG/WALL PROJECTIONS
Top View
TO CEILING
31 MIN.
18
11
Lakeville, MN Web: majesticproducts.com Phone: 888-427-3973
FIREPLACE OPENING See appliance dimension diagram in install manual - Dimension B
PRODUCT LISTING CODES
US ANSI Z21.88-2014
CAN CSA 2.33-2014
Additional information can be found online at www.majesticproducts.com
Note: Clearance from opening to perpendicualar wall
Note: Clearance from opening to perpendicualar wall
Top View
4-1/2" minimum
3' maximum
FIREPLACE OPENING See appliance dimension diagram in install manual - Dimension B
7" minimum
UNLIMITED
Combustible Non-Combustible
Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
UL307B
GS/MAJ/ECHEL72_0417