Specifications
64-5/16" [1634]
63" [1600]
ECHEL60IN
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH VIEWING AREA
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
Actual Framing Actual Framing Actual Framing Actual Framing
ECHEL60IN
Actual Framing Actual Framing Actual Framing Actual Framing
70" 72-1/4" 70" 72-1/4" 47-3/4" 48" 17-1/8" 18-1/4"
ECHEL60IN
60" Direct Vent Gas Fireplace
59-1/2" x 12-1/2"
30-1/2"
[775]
23-3/4"
[603]
47-3/4"
[1213]
24-1/2"
[622]
18-5/8"
[473]
17-1/8"
[435]
70" [1778]
J
Top
74" [1880]
63-1/8" [1603]
1" [25]
8-9/16"
[217]
o
8" [203]
CENTERED ON APPLIANCE
15-5/8"
[397]
48-1/2"
[1232]
63"
[1600]
4" [102]
2-3/4" [70]
8-9/16"
[217]
2-3/8" [60]
8-7/8"
[225]
5/8" [16]
25"
24"
[610]
61-3/16" [1554]
CFT Front PFF Front
Additional information can be found online at www.majesticproducts.com
7-1/4"
[184]
GAS ACCESS
13-1/8"
[333]
16-3/4
[425]
ELECTRICAL ACCESS
8-9/16"
[217]
FrontLeft Right
28-5/16"
[719]
10-1/16"
[256]
61-1/4" [1556]
4-15/16"
[126]
The PFF decorative front has an installed depth of 3/4" [19mm], measured from the
front of the non-combustible finishing material to the front of the decorative front.
71" [1803]
13-1/8"
[333]
23-3/8"
[594]
Specifications
MEASUREMENT FROM
TOP EDGE OPENING
24
27
30
31
TO CEILING
9
6
3
Measurement from top edge
opening to bottom of appliance
=24-1/2"
MAX.
Note:
All measurements in inches.
Acceptable on both sides of opening
31" [787]
0" [0]
0" [0]
55-1/2" [1410]
48" [1219]
1" [25]
1" [25]
Header depth
not to exceed
3-1/2" [89]
Adjust framing dimensions
for interior sheathing (such
as Sheetrock).
If appliance is installed o of oor,
maintain required clearances to
combustibles. Construct platform in
accordance with local building codes.
10" [254]
48"
[1219]
18-1/4"
[464]
72-1/4"
[1835]
31" [787]
0" [0]
0" [0]
55-1/2" [1410]
48" [1219]
1" [25]
1" [25]
ECHEL60IN
APPLIANCE LOCATION
1"
[807]
[25]
1"
"
[25]
[2019]
72-1/4
[1835]**
112-3/8"
[2854]
Refer to Section 10 of install manual for hearth,
mantel and wall projection information.
If a Heat-Zone
refer to
Section 5.E of install manual for information.
1 Heat-Zone/Heat-Duct = **dimension
2 Heat-Zones = Add 28" to **dimension
72-1/4 [1835]**
WALL PENETRATION
Do not pack with insulation or
other material.
10"
63"
[1600]
72-1/4 [1835]**
®
or Heat-Duct will be installed,
18-1/4"
[464]
12"
62"
[1570]
* Shows center of vent framing
hole for top venting. Center of hole
is 1" [25] above center of horizontal
vent pipe.
See clearances
in install manual
72-1/4
[1835]**
FRAMING DIMENSION
CLEARANCES TO COMBUSTIBLES
MANTEL PROJECTIONS - COMBUSTIBLE
MANTEL PROJECTIONS - NON-COMBUSTIBLE
Note: All measurements in inches.
MAX.
3
2
1
Measurement from top edg e of opening
to bottom of appliance = 2 4-1/2"
OVERLAP FIT
TO CEILING
13-16
6
5
4
7
6
MEASUREMENTS FROM TOP ED GE
OF THE APPLIANCE OPENING
31
MIN.
18
11
10
9
8
Note: All measurements in inches.
MAX.
4
Measurement from top edge of opening
to bottom of applianc e = 24-1/2"
INSIDE FIT
TO CEILING
14-16
31 MIN.
7
18
6
5
11
10
9
MEASUREMENTS FROM TOP E DGE
OF THE APPLIANCE OPENI NG
Lakeville, MN Web: majesticproducts.com
Phone: 888-427-3973
MANTEL LEG/WALL PROJECTIONS
Note: Clearance from
opening to
perpendicualar wall
Top View
4-1/2"
minimum
3' maximum
FIREPLACE OPENING
See appliance dimension diagram
in install manual - Dimension B
Combustible Non-Combustible
PRODUCT LISTING CODES
US ANSI Z21.88-2014
CAN CSA 2.33-2014
UL307B
Additional information can be found online at www.majesticproducts.com
Top View
7"
minimum
FIREPLACE OPENING
See appliance dimension diagram
in install manual - Dimension B
Product information provided is not
complete and is subject to change
without notice. Product installation
must adhere strictly to instructions
accompanying product to avoid risk
of fire and potential injury.
Note: Clearance from
opening to
perpendicualar wall
UNLIMITED
GS/MAJ/ECHEL60_1016