Majestic ECHEL48ST Specifications Sheet

Specifications
[635]
"
52-5/16" [1329]
51" [1295]
ECHEL48ST
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH VIEWING AREA
ECHEL48ST
40,000 BTU (NG)
34,000 BTU (LP)
ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING
Actual Framing Actual Framing Actual Framing Actual Framing
58" 60-1/4" 58" 60-1/4" 41-3/4" 42" 17-1/8" 17"
58" [1473]
17-1/8"
[435]
18-1/8"
[460]
8" [203]
o
CENTERED ON APPLIANCE
TOP
Top
62" [1575]
51-1/8" [1299]
SEE-THROUGH
Direct Vent Gas Fireplace
47-1/2" x 12-1/2"
1/2" [13]
8-9/16"
[217]
75"
[1905]
30-1/2"
[775]
23-3/4"
[603]
2-3/4" [70]
5/8" [16]
25"
[610]
24"
8-9/16"
[217]
41-3/4"
[1060]
2-3/8"
[60]
49-3/16" [1249]
24-1/2"
[622]
8-7/8"
[225]
7-1/4"
[184]
GAS ACCESS
13-1/8"
[333]
16-3/4
[425]
42-1/2"
[1080]
15-5/8"
[397]
4" [102]
8-9/16"
ELECTRICAL ACCESS
[217]
FRONTLEFT RIGHT
FrontLeft Right
23-3/8"
28-5/16"
[719]
10-1/16"
[256]
4-15/16"
[126]
49-1/4" [1250]
59" [1498]
13-1/8"
[333]
[594]
CFT FRONT PFF FRONT
Additional information can be found online at www.majesticproducts.com
The PFF decorative front has an installed depth of 3/4" [19mm], measured from the front of the non-combustible finishing material to the front of the decorative front.
Specifications
MEASUREMENT FROM TOP EDGE OPENI NG
18
20
23
26
29
31
TO CEILING
9
12
6
3
1
Measurement from t op edge opening to bottom of ap pliance = 24-1/2"
MAX.
Note:
All measurements in inches.
ECHEL48ST
APPLIANCE LOCATION
48" [1219]
1/2" [13]
17-1/8" [435]
1/2" [13]
48" [1219]
NOTICE: This see-through appliance is NOT designed or approved for an indoor/outdoor application. 2 HEAT-ZONE/HEAT-DUCTS = Add 4" to ** dimension
1 HEAT-ZONE = Add 2" to ** dimension
WALL PENETRATION
Do not pack with insulation or other material.
10"
75"
[1905]
12"
60-1/4" [1530]**
74"
[1880]
* Shows center of vent framing hole for top venting. Center of hole is 1" [25] above center of horizontal vent pipe.
FRAMING DIMENSION
10" [254]
Header depth
Header depth not to exceed 3-1/2" [89]
60-1/4"
[1530]
Adjust framing dimensions for interior sheathing (such as Sheetrock).
17" [432]
42"
[1067]
not to exceed 3-1/2" [89]
If appliance is installed o of oor, maintain required clearances to combustibles. Construct platform in accordance with local building codes.
CLEARANCES TO COMBUSTIBLES
MANTEL PROJECTIONS - COMBUSTIBLE
MANTEL PROJECTIONS - NON-COMBUSTIBLE
Note: All measurements in inches.
MAX.
4
3
2
1
6
MEASUREMENTS FROM TOP ED GE OF THE APPLIANCE OPENING
Measurement from top edg e of opening to bottom of appliance = 2 4-1/2"
31"
[787]
0" [0]
48" [1219]
0" [0]
1" [25]
55-1/2"
[1410]
MANTEL LEG/WALL PROJECTIONS COMBUSTIBLE OR NON-COMBUSTIBLE
Note: Clearance from opening to perpendicualar wall
Top View
OVERLAP FIT
TO CEILING
13-16
6
5
7
31
MIN.
18
11
10
9
8
Note: All measurements in inches.
MAX.
INSIDE FIT
TO CEILING
14-16
31 MIN.
7
18
6
5
11
10
9
4
MEASUREMENTS FROM TOP E DGE OF THE APPLIANCE OPENI NG
Measurement from top edge of opening to bottom of applianc e = 24-1/2"
4-1/2" minimum
3' maximum
FIREPLACE OPENING See appliance dimension diagram in install manual - Dimension B
Acceptable on both sides of opening
PRODUCT LISTING CODES
US ANSI Z21.88-2014
CAN CSA 2.33-2014
UL307B
Top View
FIREPLACE OPENING See appliance dimension diagram in install manual - Dimension B
Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
7" minimum
Note: Clearance from opening to perpendicualar wall
UNLIMITED
Majestic — A Brand of Hearth & Home Technologies
7571 215th Street West | Lakeville, MN 55044 877-486-9123 | majesticproducts.com
GS/MAJ/ECHEL48ST_1118
Loading...