Specifications
52-5/16" [1329]
51" [1295]
ECHEL48ST
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH VIEWING AREA
ECHEL48ST
40,000 BTU (NG)
34,000 BTU (LP)
ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING
Actual Framing Actual Framing Actual Framing Actual Framing
58" 60-1/4" 58" 60-1/4" 41-3/4" 42" 17-1/8" 17"
58" [1473]
17-1/8"
[435]
18-1/8"
[460]
8" [203]
o
CENTERED ON APPLIANCE
TOP
Top
62" [1575]
51-1/8" [1299]
ECHELON II 48
SEE-THROUGH
Direct Vent Gas Fireplace
47-1/2" x 12-1/2"
1/2" [13]
8-9/16"
[217]
75"
[1905]
30-1/2"
[775]
23-3/4"
[603]
2-3/4" [70]
5/8" [16]
25"
[610]
24"
8-9/16"
[217]
41-3/4"
[1060]
2-3/8"
[60]
49-3/16" [1249]
24-1/2"
[622]
8-7/8"
[225]
7-1/4"
[184]
GAS ACCESS
13-1/8"
[333]
16-3/4
[425]
42-1/2"
[1080]
15-5/8"
[397]
4" [102]
8-9/16"
ELECTRICAL ACCESS
[217]
FRONTLEFT RIGHT
FrontLeft Right
23-3/8"
28-5/16"
[719]
10-1/16"
[256]
4-15/16"
[126]
49-1/4" [1250]
59" [1498]
13-1/8"
[333]
[594]
CFT FRONT PFF FRONT
Additional information can be found online at www.majesticproducts.com
The PFF decorative front has an installed depth of 3/4" [19mm], measured from the
front of the non-combustible finishing material to the front of the decorative front.

Specifications
MEASUREMENT FROM
TOP EDGE OPENI NG
18
20
23
26
29
31
TO CEILING
9
12
6
3
1
Measurement from t op edge opening
to bottom of ap pliance = 24-1/2"
MAX.
Note:
All measurements in inches.
ECHEL48ST
APPLIANCE LOCATION
48" [1219]
1/2" [13]
17-1/8" [435]
1/2" [13]
48" [1219]
NOTICE:
This see-through appliance is NOT designed
or approved for an indoor/outdoor application.
2 HEAT-ZONE/HEAT-DUCTS = Add 4" to ** dimension
1 HEAT-ZONE = Add 2" to ** dimension
WALL PENETRATION
Do not pack with insulation or
other material.
10"
75"
[1905]
12"
60-1/4" [1530]**
74"
[1880]
* Shows center of vent framing
hole for top venting. Center of hole
is 1" [25] above center of horizontal
vent pipe.
FRAMING DIMENSION
10" [254]
Header
depth
Header depth
not to exceed
3-1/2" [89]
60-1/4"
[1530]
Adjust framing dimensions
for interior sheathing (such
as Sheetrock).
17" [432]
42"
[1067]
not to
exceed
3-1/2" [89]
If appliance is installed o of oor,
maintain required clearances to
combustibles. Construct platform in
accordance with local building codes.
CLEARANCES TO COMBUSTIBLES
MANTEL PROJECTIONS - COMBUSTIBLE
MANTEL PROJECTIONS - NON-COMBUSTIBLE
Note: All measurements in inches.
MAX.
4
3
2
1
6
MEASUREMENTS FROM TOP ED GE
OF THE APPLIANCE OPENING
Measurement from top edg e of opening
to bottom of appliance = 2 4-1/2"
31"
[787]
0" [0]
48" [1219]
0" [0]
1" [25]
55-1/2"
[1410]
MANTEL LEG/WALL PROJECTIONS
COMBUSTIBLE OR NON-COMBUSTIBLE
Note: Clearance from
opening to
perpendicualar wall
Top View
OVERLAP FIT
TO CEILING
13-16
6
5
7
31
MIN.
18
11
10
9
8
Note: All measurements in inches.
MAX.
INSIDE FIT
TO CEILING
14-16
31 MIN.
7
18
6
5
11
10
9
4
MEASUREMENTS FROM TOP E DGE
OF THE APPLIANCE OPENI NG
Measurement from top edge of opening
to bottom of applianc e = 24-1/2"
4-1/2"
minimum
3' maximum
FIREPLACE OPENING
See appliance dimension diagram
in install manual - Dimension B
Acceptable on both sides of opening
PRODUCT LISTING CODES
US ANSI Z21.88-2014
CAN CSA 2.33-2014
UL307B
Top View
FIREPLACE OPENING
See appliance dimension diagram
in install manual - Dimension B
Product information provided is not
complete and is subject to change
without notice. Product installation
must adhere strictly to instructions
accompanying product to avoid risk
of fire and potential injury.
7"
minimum
Note: Clearance from
opening to
perpendicualar wall
UNLIMITED
Majestic — A Brand of Hearth & Home Technologies
7571 215th Street West | Lakeville, MN 55044
877-486-9123 | majesticproducts.com
GS/MAJ/ECHEL48ST_1118