Specifications
52-5/16" [1329]
51" [1295]
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH VIEWING AREA
ECHEL48
40,000 BTU (NG)
34,000 BTU (LP)
ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING
Actual Framing Actual Framing Actual Framing Actual Framing
58" 60-1/4" 58" 60-1/4" 41-3/4" 42" 17-1/8" 18-1/4"
ECHELON II 48
Direct Vent Gas Fireplace
47-1/2" x 12-1/2"
ECHEL48
30-1/2"
[775]
23-3/4"
[603]
2-3/4" [70]
8-9/16"
[217]
41-3/4"
[1060]
2-3/8" [60]
18-5/8"
[473]
24-1/2"
[622]
17-1/8"
8-7/8"
[225]
[435]
7-1/4"
[184]
GAS ACCESS
58" [1473]
TOP
62" [1575]
51-1/8" [1299]
o
8" [203]
CENTERED ON APPLIANCE
15-5/8"
[397]
ELECTRICAL ACCESS
1" [25]
8-9/16" [217]
42-1/2"
[1080]
63"
[600]
4" [102]
8-9/16"
[217]
5/8" [16]
25"
24"
[610]
49-3/16" [1249]
CFT FRONT PFF FRONT
Additional information can be found online at www.majesticproducts.com
13-1/8"
[333]
FRONTLEFT RIGHT
28-5/16"
[719]
16-3/4
[425]
10-1/16"
[256]
49-1/4" [1250]
4-15/16"
[126]
The PFF decorative front has an installed depth of 3/4" [19mm], measured from the
front of the non-combustible finishing material to the front of the decorative front.
59" [1498]
13-1/8"
[333]
23-3/8"
[594]

Specifications
MEASUREMENT FROM
TOP EDGE OPENI NG
18
20
23
26
29
31
TO CEILING
9
12
6
3
1
Measurement from t op edge opening
to bottom of ap pliance = 24-1/2"
MAX.
Note:
All measurements in inches.
Header depth
not to exceed
3-1/2" [89]
Adjust framing dimensions
for interior sheathing (such
as Sheetrock).
If appliance is installed o of oor,
maintain required clearances to
combustibles. Construct platform in
accordance with local building codes.
10" [254]
42"
[1067]
18-1/4"
[464]
60-1/4"
[1530]
31" [787]
0" [0]
0" [0]
55-1/2" [1410]
48" [1219]
1" [25]
1" [25]
31" [787]
0" [0]
0" [0]
55-1/2" [1410]
48" [1219]
1" [25]
1" [25]
ECHEL48
APPLIANCE LOCATION
1"
[724]
[25]
1"
"
[25]
[1797]
60-1/4
[1530]**
100-3/8"
[2550]
Refer to Section 10 of install manual for hearth,
mantel and wall projection information.
®
If a Heat-Zone
refer to
60-1/4 [1530]**
or Heat-Duct will be installed,
Section 5.E of install manual for information.
2 HEAT-ZONES = Add 4" to ** dimension
1 HEAT-ZONE = Add 2" to ** dimension
WALL PENETRATION
Do not pack with insulation or
other material.
10"
63"
[1600]
12"
60-1/4 [1530]**
18-1/4"
[464]
62"
[1570]
* Shows center of vent framing
hole for top venting. Center of hole
is 1" [25] above center of horizontal
vent pipe.
See clearances
in install manual
60-1/4
[1530]**
FRAMING DIMENSION
CLEARANCES TO COMBUSTIBLES
MANTEL PROJECTIONS - COMBUSTIBLE
MANTEL PROJECTIONS - NON-COMBUSTIBLE
Note: All measurements in inches.
MAX.
6
5
4
3
2
1
7
6
MEASUREMENTS FROM TOP ED GE
OF THE APPLIANCE OPENING
Measurement from top edg e of opening
to bottom of appliance = 2 4-1/2"
13-16
8
OVERLAP FIT
TO CEILING
31
MIN.
18
11
10
9
Note: All measurements in inches.
MAX.
INSIDE FIT
TO CEILING
14-16
31 MIN.
7
18
6
5
11
10
9
4
MEASUREMENTS FROM TOP E DGE
OF THE APPLIANCE OPENI NG
Measurement from top edge of opening
to bottom of applianc e = 24-1/2"
Majestic — A Brand of Hearth & Home Technologies
7571 215th Street West | Lakeville, MN 55044
877-486-9123 | majesticproducts.com
MANTEL LEG/WALL PROJECTIONS
COMBUSTIBLE OR NON-COMBUSTIBLE
Note: Clearance from
opening to
perpendicualar wall
Top View
4-1/2"
minimum
3' maximum
FIREPLACE OPENING
See appliance dimension diagram
in install manual - Dimension B
Acceptable on both sides of opening
PRODUCT LISTING CODES
US ANSI Z21.88-2014
CAN CSA 2.33-2014
UL307B
Top View
FIREPLACE OPENING
See appliance dimension diagram
in install manual - Dimension B
Product information provided is not
complete and is subject to change
without notice. Product installation
must adhere strictly to instructions
accompanying product to avoid risk
of fire and potential injury.
7"
minimum
Note: Clearance from
opening to
perpendicualar wall
UNLIMITED
GS/MAJ/ECHEL48_1118