Specifications
40-5/16" [1024]
39" [991]
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH VIEWING AREA
ECHEL36
30,000 BTU (NG)
27,000 BTU (LP)
ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING
Actual Framing Actual Framing Actual Framing Actual Framing
46-3/16" 48-1/4" 46-3/16" 48-1/4" 41-3/4" 42" 17-1/8" 18-1/4"
ECHELON II 36
Direct Vent Gas Fireplace
35-1/2" x 12-1/2"
ECHEL36
30-1/2"
[775]
23-3/4"
[603]
2-3/4"
[70]
8-9/16"
[217]
41-3/4"
[1060]
2-3/8"
[60]
18-5/8"
[473]
24-1/2"
[622]
17-1/8"
[435]
8-7/8"
[225]
7-1/4"
[184]
GAS ACCESS
46-3/16" [1173]
o
CENTERED ON APPLIANCE
TOP
50" [1270]
39-1/4" [997]
ELECTRICAL ACCESS
8" [203]
8-9/16"
15-5/8"
[397]
1" [25]
[217]
42-1/2"
[1080]
63" [1600]
4" [102]
8-9/16"
[217]
5/8" [16]
25"
24"
[610]
37-3/16" [945]
CFT FRONT PFF FRONT
Additional information can be found online at www.majesticproducts.com
13-1/8"
[333]
FRONTLEFT RIGHT
28-5/16"
16-3/4
[425]
[719]
10-1/16"
[256]
37-1/4" [946]
4-15/16"
[126]
The PFF decorative front has an installed depth of 3/4" [19mm], measured from the
front of the non-combustible finishing material to the front of the decorative front.
47" [1194]
13-1/8"
[333]
23-3/8"
[594]

Specifications
MEASUREMENT FROM
TOP EDGE OPENI NG
18
20
23
26
29
31
TO CEILING
9
12
6
3
1
Measurement from t op edge opening
to bottom of ap pliance = 24-1/2"
MAX.
Note:
All measurements in inches.
31" [787]
0" [0]
0" [0]
55-1/2" [1410]
48" [1219]
1" [25]
1" [25]
Header depth
not to exceed
3-1/2" [89]
Adjust framing dimensions
for interior sheathing (such
as Sheetrock).
If appliance is installed o of oor,
maintain required clearances to
combustibles. Construct platform in
accordance with local building codes.
10" [254]
42"
[1067]
18-1/4"
[464]
48-1/4"
[1226]
31" [787]
0" [0]
0" [0]
55-1/2" [1410]
48" [1219]
1" [25]
1" [25]
ECHEL36
APPLIANCE LOCATION
1"
[622]
[25]
1"
"
[25]
[1588]
48-1/4"
[1226]**
88-1/8"
[2239]
Refer to Section 10 of install manual for hearth,
mantel and wall projection information.
®
If a Heat-Zone
refer to
Section 5.E of install manual for information.
48-1/4" [1226]**
WALL PENETRATION
Do not pack with insulation or
other material.
10"
63"*
[1600]
12"
48-1/4" [1226]**
or Heat-Duct will be installed,
2 HEAT-ZONES = Add 4" to ** dimension
1 HEAT-ZONE = Add 2" to ** dimension
18-1/4"
[464]
62"
[1570]
* Shows center of vent framing
hole for top venting. Center of hole
is 1" [25] above center of horizontal
vent pipe.
See clearances
in install manual
48-1/4"
[1226]**
FRAMING DIMENSION
CLEARANCES TO COMBUSTIBLES
MANTEL PROJECTIONS - COMBUSTIBLE
MANTEL PROJECTIONS - NON-COMBUSTIBLE
Note: All measurements in inches.
MAX.
5
4
3
2
1
6
MEASUREMENTS FROM TOP ED GE
OF THE APPLIANCE OPENING
Measurement from top edg e of opening
to bottom of appliance = 2 4-1/2"
MANTEL LEG/WALL PROJECTIONS
COMBUSTIBLE OR NON-COMBUSTIBLE
Note: Clearance from
opening to
perpendicualar wall
Top View
OVERLAP FIT
TO CEILING
13-16
6
7
31
MIN.
18
11
10
9
8
Note: All measurements in inches.
MAX.
Majestic — A Brand of Hearth & Home Technologies
7571 215th Street West | Lakeville, MN 55044
877-486-9123 | majesticproducts.com
INSIDE FIT
TO CEILING
14-16
31 MIN.
7
18
6
5
11
10
9
4
MEASUREMENTS FROM TOP E DGE
OF THE APPLIANCE OPENI NG
Measurement from top edge of opening
to bottom of applianc e = 24-1/2"
4-1/2"
minimum
3' maximum
FIREPLACE OPENING
See appliance dimension diagram
in install manual - Dimension B
Acceptable on both sides of opening
PRODUCT LISTING CODES
US ANSI Z21.88-2014
CAN CSA 2.33-2014
UL307B
Top View
FIREPLACE OPENING
See appliance dimension diagram
in install manual - Dimension B
Product information provided is
not complete and is subject to
change without notice. Product
installation must adhere strictly
to instructions accompanying
product to avoid risk of fire and
potential injury.
7"
minimum
Note: Clearance from
opening to
perpendicualar wall
UNLIMITED
GS/MAJ/ECHEL36_1118