PRODUCT SPECIFICATIONS
47”
(1194mm)
Min. Rough Opening Width
Min. Rough
Opening
Depth
1/2” or 5/8”
2-1/2”
(64mm)
5”
2”
Min. Rough
Opening
Height
42”
(1067mm)
38-15/16”
(989mm)
46-1/2”
(1181mm)
20-3/8”
(516mm)
20-3/4”
(527mm)
14-9/16”
(370mm)
38-3/16”
(970mm)
48-1/16” (1221mm)
19-1/8”
(486mm)
22-5/16”
(567mm)
46-5/16”
(1176mm)
42-7/16”
(1079mm)
34-1/2”
(876mm)
23-3/16”
(589mm)
1/2”
5/8”
1/2”
5/8”
40-3/8”
(1026mm)
3-3/8”
(86mm)
12-1/16”
(306mm)
7-3/8”
(187mm)
34-5/8”
(880mm)
600MDVP Cameo
Direct Vent Fireplace System
FRAMING DIMENSIONS
ACTUAL DIMENSIONS
Actual size: 47" W x 465⁄16 " H x 225⁄16" D
(1194 mm x 1176 mm x 567 mm)
Viewing area: 3815⁄16" W x 233⁄16"H (903 sq. in.)
(989 mm x 589 mm)
Framing Dimensions: 48" W x 461⁄2" H x 203⁄8"D
(1221 mm x 1181 mm x 516 mm)
FIELD INSTALLED ACCESSORIES
• Curved Trim: Black
• Firebrick: Cottage Clay or Tavern Brown
• Variable Thermostat Controlled Dual Forced Air Blower
(160 CFM) – BLOTSDV
• Signature Command Dual Forced Air Blower (160 CFM) -
BLOTBLDVSC
• Ambient Technologies™ Remote Controls and Thermostats
• Safety Screen Barrier Included
Opening
Depth
20-3/8”
(516mm)
Min. Rough
Opening
Height
22-5/16”
(567mm)
46-1/2”
(1181mm)
46-5/16”
(1176mm)
19-1/8”
(486mm)
Min. Rough Opening Width
48-1/16” (1221mm)
5”
2”
42-7/16”
(1079mm)
23-3/16”
(589mm)
34-1/2”
(876mm)
2-1/2”
(64mm)
47”
(1194mm)
3-3/8”
(86mm)
12-1/16”
(306mm)
(970mm)
38-15/16”
(989mm)
5/8”
1/2”
1/2”
5/8”
56-1/4”
(1429mm)
(1067mm)
7-3/8”
(187mm)
42”
34-5/8”
(880mm)
40-3/8”
(1026mm)
14-9/16”
(370mm)
1/2” or 5/8”
20-3/4”
(527mm)
Page 1 of 2
56-1/4”
(1429mm)
39-3/4”
(1010mm)
79-1/2”
(2019mm)
PRODUCT SPECIFICATIONS
600MDVP Cameo
Direct Vent Fireplace System
MANTEL CLEARANCES
NOTE: The combustibles area above the facing must
not protrude more than 1/2" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in the owner’s manual.
Ceiling
72”
(1829 mm)
Minimum
6”
(152 mm)
Min.
12”
10”
12"
10
”
9¹⁄₂”
8”
6”
8
Side Wall
12”
(305 mm)
Maximum Depth
4”
2¹⁄₂”
”
7”
6”
Combustible
Mantel
Stud
Header
Standoff
Insulation
Board
12”
(305 mm)
Minimum
TECHNICAL SPECIFICATIONS
Max. BTU Input: 32,000 BTU/hr
Ignition System: Signature Command™ System
Gas Type: Natural or LP
Flue Type: Uses DVP pipe which can be converted to SLP
for vertical applications (see manual for details)
Termination: Rear/Top Vent Convertible
Clearance on Flue for Interior: 3” Top 1” Bottom and Sides*
Clearance on Flue for Outside Wall: 1”
Clearance on Fireplace: 0”
CSA Design Certified
CLEARANCE TO FLUE
Minimum 6" (152 mm) clearance to the top along horizontal
length until flue penetrates outside wall*
Minimum of 1" (25 mm) clearance to combustibles permitted
at outside wall
CLEARANCE TO COMBUSTIBLES
Fireplace: 0" clearance to standoffs on all sides
Floor of Unit to Ceiling: 72" (1829 mm) to combustibles
Firebox Opening to Wall: 6" (152 mm)
Hearth Requirement: 0"
EFFICIENCY DATA
Thermal Efficiency: Up to 80%
AFUE Efficiency: Up to 70%
P4 Canada Efficiency: Up to 74%
* If vertical rise is 7 1/2' (2.29 mm) or higher when in top vent configuration only,
the vent clearance to combustibles is 1" (25 mm) on all sides of the horizontal
run.
Top of Fireplace
Opening
FP2409
Side View
Finish Wall
Combustible
Material Area
1”
1¹⁄₂”
FP2410
2¹⁄₂”
3¹⁄₂”
4¹⁄₂”
3”
5”
6”
45°
149 Cleveland Drive, Paris, Kentucky 40361
www.majesticproducts.com
To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the product and all applicable building or fire
codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this brochure are for illustrative purposes only and are not intended for, nor should they be used
as a substitute for the instructions packaged with the unit. Appearance and specifications of the product are subject to change without notice. ©2015 Hearth & Home Technologies 1115v2
Page 2 of 2