Specifications
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH FIREPLACE OPENING
BE42
Actual Framing Actual Framing Actual Framing Actual Framing
47" 48" 29-3/4" 48" 39-1/2" 39-3/4" 21-3/8" 21-1/2"
ROYALTON
42" Wood Fireplace
42" x 21"
BE42
21"
[533]
18-3/4"
[476]
14-7/8"
[378]
47" [1194]
Top View
7-3/8"
[187]
21-3/8"
[543]
7-1/2"
[191]
21"
[533]
7-1/2"
[191]
14-1/8"
[359]
39-1/2"
[1003]
Gas
Knockout
Outside
Gas
Knockout
Air
9-1/4"
[235]
17-7/8"
[453]
42" [1067]
Front View
Left Side View Right Side View
9-1/4"
[235]
Additional information can be found online at www.majesticproducts.com or www.fireplaces.com
21-1/2"
[546]*
39-3/4"
[1010]**
48" [1219]
2" [51] min
air space
clearance
from chimney
Header MUST NOT
be notched!
8"
[203]
†
†
Extra space needed for outside air
connection. If outside air duct has no
bend, this dimension may be reduced
as long as minimum clearances are met
* If interior chase will be drywalled,
add thickness to this measurement.
** Adjust header height for raised
floor under fireplace
15"
[381]
under the front of the fireplace
Specifications
BE42
APPLIANCE LOCATION
52-1/4" [1327]
17"
[429]
48" [1219]
56" [1422]
48"
37-1/4"
[946]
48"
[1219]
minimum
As a
room
divider
65-1/2"
[1664]
[1219]
73-7/8"
[1876]
48"
[1219]
21-1/2"
[546]
Across a
corner
In an exterior chase
or projecting into a
garage
Along a wall
56" [1422]
48" [1219]
MANTEL PROJECTIONS
Combustible
Wall
2 x 4 stud wall
Standoffs
Seal joint with
non-combustible
sealant
1-1/2 [38]
maximum
Non-combustible
Decorative Facing
such as: steel, iron,
brick, tile, concrete,
slate, glass or plasters
Combustible
Decorative Facing
12" [305]
12" [305]
minimum
6" [152]
minimum
Measured from top of fireplace opening
MANTEL LEG/WALL PROJECTIONS
21-1/2"
[546]
12"
[305]
min.
12"
[305]
min.
21-1/2"
[546]
7 ft [2134]
minimum base
of fireplace to
ceiling
1/2" [13] all
configurations
FRAMING DIMENSIONS
CLEARANCES TO COMBUSTIBLES
Storm Collar
Roof Flashing
(attic)
(insulation)
2" [51] minimum
Ceiling Firestop
(roof)
Shaded areas represents
2" [51] minimum air space
clearance required around
pipe.
Attic Insulation Shield
(ceiling)
Offset/Return (secured
with hanger straps
(ceiling)
Must have 2" [51] minimum
clearance to header
FLUSH
FRONT
11-1/4"
[286]
50° angle
12"
HEARTH EXTENSIONS
4" [102] minimum between
bottom of fireplace opening
and finished surface of
hearth extension
12"
[305]
66"
[1676]
BRICK
FRONT
42" [1067]
39° angle
47" [1194]
12"
[305]
42"
[1067]
12"
[305]
20"
[508]
4"
[102]
9-3/4"
[248]
HEARTH EXTENSION CONSTRUCTION
PRODUCT LISTING CODES
US UL 127
CAN ULC-S610
Additional information can be found online at www.majesticproducts.com
Lakeville, MN Phone: (800) 927-6841
Web: www.majesticproducts.com
48"
[1219]
0" to floor
1/2" [13] Micore Hearth Extension
(or equivalent insulation. See
Installation Manual).
Floor constructed of wood or
other combustible material
0" to level
of standoffs
1/2" [13] to back &
sides of appliance
non-combustible
sealant
Tile, stone or other
noncombustible
material
2" [51] of the Protective
Metal Hearth Strip is required
Product information provided is not
complete and is subject to change without
notice. Product installation must adhere
strictly to instructions accompanying
product to avoid risk of fire and potential
injury.
Fireplace
Opening
4" [102]
minimum
MAJ/BE42_0817