Majestic BE42 Specifications

29-3/4" [756]
Specifications
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH FIREPLACE OPENING
BE42
Actual Framing Actual Framing Actual Framing Actual Framing
47" 48" 29-3/4" 48" 39-1/2" 39-3/4" 21-3/8" 21-1/2"
ROYALTON
42" Wood Fireplace
42" x 21"
BE42
21"
[533]
18-3/4"
[476]
14-7/8"
[378]
47" [1194]
Top View
7-3/8"
[187]
21-3/8"
[543]
7-1/2"
[191]
21"
[533]
7-1/2"
[191]
14-1/8"
[359]
39-1/2"
Gas
Knockout
Outside
Gas
Knockout
Air
9-1/4"
[235]
17-7/8"
[453]
42" [1067]
Front View
Left Side View Right Side View
9-1/4"
[235]
Additional information can be found online at www.majesticproducts.com or www.fireplaces.com
21-1/2"
[546]*
39-3/4"
[1010]**
48" [1219]
2" [51] min air space clearance from chimney
Header MUST NOT be notched!
8"
[203]
Extra space needed for outside air connection. If outside air duct has no bend, this dimension may be reduced as long as minimum clearances are met
* If interior chase will be drywalled, add thickness to this measurement.
** Adjust header height for raised floor under fireplace
15"
[381]
[305]
under the front of the fireplace
Continuous,
Combustible Object
Specifications
BE42
APPLIANCE LOCATION
52-1/4" [1327]
17"
[429]
48" [1219] 56" [1422]
48"
37-1/4"
[946]
48"
[1219]
minimum
As a
room
divider
65-1/2"
[1664]
[1219]
73-7/8" [1876]
48"
[1219]
21-1/2"
[546]
Across a
corner
In an exterior chase
or projecting into a
garage
Along a wall
56" [1422]
48" [1219]
MANTEL PROJECTIONS
Combustible
Wall
2 x 4 stud wall
Standoffs
Seal joint with non-combustible sealant
1-1/2 [38] maximum
Non-combustible Decorative Facing such as: steel, iron, brick, tile, concrete, slate, glass or plasters
Combustible Decorative Facing
12" [305]
12" [305] minimum
6" [152]
minimum
Measured from top of fireplace opening
MANTEL LEG/WALL PROJECTIONS
21-1/2"
[546]
12"
[305]
min.
12"
[305]
min.
21-1/2"
[546]
7 ft [2134] minimum base of fireplace to
ceiling
1/2" [13] all
configurations
FRAMING DIMENSIONS
CLEARANCES TO COMBUSTIBLES
Storm Collar
Roof Flashing
(attic)
(insulation)
2" [51] minimum
Ceiling Firestop
(roof)
Shaded areas represents 2" [51] minimum air space clearance required around pipe.
Attic Insulation Shield
(ceiling)
Offset/Return (secured with hanger straps
(ceiling)
Must have 2" [51] minimum clearance to header
FLUSH FRONT
11-1/4"
[286]
50° angle
12"
HEARTH EXTENSIONS
4" [102] minimum between bottom of fireplace opening and finished surface of hearth extension
12"
[305]
66"
[1676]
BRICK
FRONT
42" [1067]
39° angle
47" [1194]
12"
[305]
42"
[1067]
12"
[305]
20"
[508]
4"
[102]
9-3/4"
[248]
HEARTH EXTENSION CONSTRUCTION
PRODUCT LISTING CODES
US UL 127
CAN ULC-S610
Additional information can be found online at www.majesticproducts.com
Lakeville, MN Phone: (800) 927-6841 Web: www.majesticproducts.com
48"
[1219]
0" to floor
1/2" [13] Micore Hearth Extension (or equivalent insulation. See Installation Manual).
Floor constructed of wood or other combustible material
0" to level of standoffs
1/2" [13] to back & sides of appliance
non-combustible sealant
Tile, stone or other noncombustible material
2" [51] of the Protective Metal Hearth Strip is required
Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
Fireplace Opening
4" [102]
minimum
MAJ/BE42_0817