Majestic ASH50 Specifications Sheet

Page 1
Specifications
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH FIREPLACE OPENING
Actual Framing Actual Framing Actual Framing Actual Framing
ASH50
60-7/8"
(1524mm)
61-7/8"
(1549mm)
45-1/8"
(1147mm)
61-7/8"
(1549mm)
74-1/8"
(1883mm)
74-1/2"
(1892mm)
27-1/2"
(699mm)
ASHLAND
50" Wood Fireplace
28-1/2"
(724mm)
50" x 38"
(1270mm x 965mm)
ASH50
Front View
74° TYP.
5-1/2"
[140]
45-1/8"
[1146]
Top View
22-1/2"
[572]
11"
[281]
[965]
38"
27-1/2"
[699]
54"
[1372]
61-7/8"
[1572]
70-3/4"
[1797]
74-1/8"
[1883]
50" [1270]
Gas Line
Knockout
6-7/8"
5"
[129]
16-1/8"
[408]
[175]
11-1/8"
[282]
Left Side View Right Side View
Additional information can be found online at www.majesticproducts.com or www.fireplaces.com
3-3/4
[97]
6-7/8"
[175]
11-1/8"
[282]
16-1/8"
[408]
Gas Line
Knockout
5"
[129]
Page 2
minimum
air connection. If outside air duct
19-3/4"
4" [102]
[610]
22-3/8"
Continuous,
1" Micore or equivalent insulation (see Install Manual)
above the bottom of the fireplace. Finished hearth
Combustible Object
Specifications
ASH50
APPLIANCE LOCATION
)
)
)
)
)
)
)
)
)
)
)
)
61-7/8" [1572] 85-7/8" [2181]
In an exterior chase
or prjecting into a
garage
24" [610]
from fireplace opening to
any perpendicular wall
Along a wall
85-7/8" [2181]
61-7/8" [1572]
)
)
)
)
)
)
)
)))))))))))))))
51-5/8"
[1311]
25-1/4"
[641]
)
)
)
)
)
)
)
)
)
As a
room
divider
)
)
[2337]
[1219]
92"
48"
73 [1854]
61-7/8"
[1572]
)
)
)
)
)
)
)
)
)
)
)
61-7/8"
[1572]
103-1/4"
[2623]
28-1/2"
[724]
)
)
)
)
)
)
)
)
)
)
))
)
))
)
)
)
)
)
Across a
corner
MANTEL PROJECTIONS
2 x 4 stud header
Standoffs
Notches
Non-combustible Decorative Facing such as: steel, iron, brick, tile, concrete, slate, glass, plasters.
Combustible Wall & Decorative Facing
12" [305]
Mantel
Grid represents
1" squares
12" [305] minimum
6" [152]
1-1/2" [38] maximum
minimum
Measured from top of fireplace opening
Seal joint with non-combustible sealant
22" [559] minimum
MANTEL LEG/WALL PROJECTIONS
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)))))))))))))
))
7 ft [2134]
minimum
floor to ceiling
28-1/2"
[724]
28-1/2"
[724]
1/2" [13] all
configurations
FRAMING DIMENSIONS
21" min
[533]
2" [51] minimum air space clearance from chimney
Extra space needed for outside
has no bend, this dimension may
**74-1/2"
[1892]
61-7/8"
*28-1/2"
[724]
* If interior of chase will be drywalled, add the thickness to this measurement. ** Adjust header height for raised floor under fireplace.
[305]
12"
[1572]
be reduced as long as minimum clearances are met.
12"
[305]
CLEARANCES TO COMBUSTIBLES
1" [25]
(attic)
(insulation)
2" [51] minimum
Ceiling Firestop
Storm Collar
Chase Top Flashing
(roof)
Shaded areas represents 2" [51] minimum air space clearance required around pipe.
Attic Shield Collar
Attic Insulation Shield
(ceiling)
(ceiling)
Must have 2" [51] minimum clearance to any cumbustible materials including header
Framing must be extended straight up 84" [2134] from base of fireplace.
HEARTH EXTENSIONS
[568]
FLUSH FRONT
50" [1270]
50° angle
18-1/2"
[470]
60-7/8" [1546]
24"
12"
[305]
50"
[1270]
74"
[1880]
(R value of hearth must be
equal to or greater than 2.32)
BRICK
FRONT
39° angle
12"
[305]
20" [508] min raised 30" [762] min flush
24"
[610]
[500]
HEARTH EXTENSION CONSTRUCTION
PRODUCT LISTING CODES
US UL 127
Additional information can be found online at www.majesticproducts.com
Phone: (800) 927-6841
www.majesticproducts.com
48"
[1219]
0" to floor
1/2" Durock
Floor constructed of wood or other combustible material
non-combustible sealant
0" to level of standoffs
1-1/2" [38] to back & sides of appliance (except at nailing flanges where it is 1/2" [13])
Tile, stone or other non-combustible material
The bottom of the fireplace opening is 3-3/4" [95]
extension must NOT extend above this level.
*
Protective
Fireplace
Metal Hearth Strip
* 2" [51]
*
Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
MAJ/ASH50_0418
Loading...