Main Heating boilers Range Guide RANGE GUIDE

Page 1
MAIN HEATING RANGE GUIDE
Combi and system boilers and cylinders.
Page 2
At Main, we only oer products and services that are straightforward, eective, ecient – and don’t break the bank.
That means a wide range of reliable, easy-to-install, low maintenance boilers, cylinders and water heaters – as well as a range of heating controls that save your customers even more money. On top of all that, Main training and support services are there to oer help when you want it.
It’s everything you need.
2
Page 3
Our heritage
We’ve been designing and building boilers in the UK for more than 75 years, working to the highest
standards and ensuring the highest quality.
It’s given us a proud reputation for excellence in our industry – a reputation that’s strengthened
with each outstandingly reliable boiler, cylinder or water heater we develop.
It all means that when you install Main, you install a product you can depend on to get the job done.
Our range
Of course, we don’t just oer boilers and accessories, we also have a range of unventedhot water
cylinders and water heaters to complement them. You’ll find all the details you need onall our
products in this easy-to-understand brochure – including technical specifications and flue options.
Our service
To make it easier for you to get the job done, we oer FREE training courses and technical
support,soyou’ll always have the very latest Main product knowledge. And because our dedicated
training centres are spread across the UK, you’ll always be within easy reach, wherever you are.
Although our products are easy to install and simple to maintain, sometimes you just need a bit
of help and advice. That’s why we also have Baxi Customer Support – our service division with
a dedicated service centre and field engineers.
You can reach them on 0344 871 1545.
Our heritage
We’ve been designing and building boilers in the UK for more than 75 years, working to the
highest standards and ensuring the highest quality.
It’s given us a proud reputation for excellence in our industry – a reputation that’s strengthened
with each outstandingly reliable boiler, cylinder or water heater we develop.
It all means that when you install Main, you install a product you can depend on to get the job done.
3
Page 4
You asked for it...
20%
Hydrogen
25 and 30kW
29.5kg lift weight
Compact cupboard fit
Front access to all components
Central top flue
Brass hydraulics block
Optional stand-o frame
Certified to work with 20% hydrogen
Key features Benefits
5 Year Warranty
Outputs 25kW and 30kW To suit most property sizes
Compact cupboard fit Can be installed discreetly
Lightweight 29.5kg lift weight
Front access to all components Saves time when servicing, allowing for ease of maintenance and repair
Fully modulating and highly ecient Boiler intelligently uses the right amount of fuel to meet the set
Central top flue For ease of replacement
Flueing options of up to 20m Allowing greater flexibility of siting
Optional outdoor weather sensor available Enhances system control and customer comfort
Ease of service No special tools or replacement seals required for standard service
Vertical packaging easy to transport and unpack
Clean aesthetic finish Boiler casing hides system connections for cleaner finish
Opentherm interface Compatible with Baxi uSense wired thermostat
Rigid filling link For a neater finish
4
For peace of mind
central heating temperatures, saving money on fuel bills
Allows for ease of access to all installation accessories from top of the packaging
Page 5
Main Eco
Compact Combi
We designed the Main Eco Compact Combi after talking to installers across the UK to find out what they want from a combi boiler.
In addition to Main Heating’s tried and tested technology, this boiler is cupboard-fit, lightweight, compatible with Baxi uSense wired smart thermostat and has a five year warranty
Compatible accessories
.
7649277
Baxi uSense wired smart thermostat
720030701
MAIN RF digital 7-day programmable roomstat
Subject to registration and an annual service. Terms and conditions apply. Visit baxi.co.uk/warranty
7683084
Baxi IFOS In Flue Outdoor Sensor Kit
7703233
On wall outdoor sensor
720971601
Baxi wired room thermostat
5
Page 6
MAIN ECO COMPACT COMBI
Technical specifications
Dimensions and minimum clearances
Boiler dimensions
Width [A] Height [B] Depth [C]
390mm 700mm 285mm
Service clearances
A
DD
E
B
Side [D] Upper [E] Lower [F] Front [G]
5mm* 178mm* 200mm* 5mm* in operation
*450mm for servicing
Included with the Main Eco Compact Combi
Wall mounted bracket
G
Literature and fitting pack
F
Copper pipe tails
C
Rigid filling link
6
Page 7
Main Eco Compact
Main Eco Compact Combi Units
Sales code (boiler only) 77 14519 77 14161
Combi 25kW
Main Eco Compact
Combi 30kW
Controls and accessories
Reset button Yes Yes
User adjustable DHW temperature Yes Yes
User adjustable CH temperature Yes Yes
LED temp/status/fault diagnosis display Yes Yes
Integral 24hr electro-mechanical timer (optional 720971401) No No
Gas
Natural gas Yes Yes
Nominal inlet supply pressure mbar 20 20
Maximum gas rate m3/h 2.71 3.26
Propane LPG No No
Heat input central heating (CH)
Heat output CH non-condensing
Heat output CH condensing
Heat input domestic hot water kW Max Gross (QnwHs) 25.77 30.00
Heat output domes tic hot water kW Max (Pn) 25.00 30.93
kW Max Gross(QnHs)
kW Min Gross(QnHs)
kW Max (Pn)
kW min (P n)
kW max (Pnc)
kW min (P nc)
22.86
6.87
20.00
6.20
21.16
6.70
22.86
6.87
20.00
6.20
21.20
6.70
ErP product information
NOx class 6 6
Space heating eciency class A A
Water heating declared load profile XL XL
Water heating eciency class A A
Seasonal space heating energy eciency % 93 93
Electrical
Electrical supply Volts/Hz 230/50 230/50
Permanent live required Yes Yes
Fitted electrical cable No No
Power consumption Watts 68 68
External fuse rating Amps 3 3
Internal fuse rating Amps F2AH250V F2AH250V
Ingress protection rating IPX5D IPX5D
Integral ‘boiler only’ frost thermostat Yes Yes
Mechanical
Stand o frame – optional (7715535)
Pre-plumbing/wall mounting jig – optional (7715591)
Isolating valves
Gas supply connection
Central heating connections
Domestic hot water connections
Condensate drain connection
Safety discharge connection
Safety discharge pressure
Temporary rigid filling loop included
mm 22 22
mm 22 22
mm 15 15
mm 21.50 21.50
mm 15 15
bar 3 3
Yes Yes
Yes Yes
Yes Yes
Yes Yes
Hydraulic
Domes tic hot water output (raised 35°C) (max)
Domes tic hot water operating flow rate (min)
Domestic hot water operating pressure (min) bar 0.5 0.5
Domes tic hot water system pressure (max) bar 8 8
CH safety discharge p ressure bar 3 3
Integral automatic bypass Yes Yes
Integral expansion vessel capacity litres 7 7
Max capacity of central heating sy stem litres 100 10 0
Compartment ventilation requirement No No
CH system inhibitor required Yes Yes
24 hour pump exercise Yes Yes
Pump overrun Yes Yes
l/min 10.2 12.2
l/min 2* 2*
Concentric flue systems
Concentric flue diameters mm 60/100 and 80/125
Standard horizontal flue kit length (60/100mm) mm 685 685
Max equiv length horizontal/vertical (60/100mm) m 10 10
Max equiv length horizontal/vertical (80/125mm) m 20 20
Equivalent length per 135º bend m 0.50 0.50
Equivalent length per 93º bend m 1.00 1.00
Weights
Max installation lift weight kg 29 29
Gross packaged boiler weight kg 32 32
* W here low flow tap s or fittings a re intended to b e used in the DH W system conne cted it is stro ngly recomm ended that t he DHW flow rate DO ES NOT fall belo w 2.5 l/min.
This wi ll ensure relia ble operati on of DHW func tion
7
Page 8
MAIN ECO COMPACT COMBI
Electrical Power
Terminal
Pressure Gauge
What’s inside?
Drip Tr ay
Expansion vessel
top up valve
Overheat Thermostat Sensor
Burner Mixing Chamber
Stainless Steel Heat Exchanger
Fan
Flue
Combustion
Checking Points
Ignition and
Flame Sensing
Electrode
Air Inlet Silencer
Expansion
Vessel
8
Water Pressure Sensor
Pump
Brass Hydraulic
Gas Valve
Condensate Drain
Electrical Power Terminal
Pressure Gauge
Page 9
Flue solutions
Horizontal concentric flues Ø 60/100mm
Multifit Flue Group A
Item Description (multifit) flue system Colour Specification
Horizontal telescopic flue inc. low profile elbow
1
and fixing screws
Horizontal telescopic flue inc. low profile elbow
2
and fixing screws
3 1m flue ex tension inc. fixing screws White 1000mm 100mm 720648801
4 93° flue bend inc. fixing screws White 93° 100mm 720648401
5 135° flue ben d inc. fixing screws (pair) White 135° 100mm 720647901
Standard horizontal flue inc. low profile elbow
6
and fixing screws
White pipe/white
terminal
White pipe/black
terminal
White pipe/black
terminal
315mm – 500mm 100mm 720599401
315mm – 500mm 100mm 720598701
685mm 100m m 7222019
Plume displacement kits Ø 60/100mm
Multifit Flue Group A
Item Description (multifit) flue system Colour Specification
Plume d isplacement ter minal kit for tel escopic flue
7
inc. 1m e xtension and b rackets
Plume d isplacement ter minal kit for tel escopic flue
8
inc. 1m e xtension and b rackets
9 Plume displacement kit extension and brackets White 1000mm 60mm 720 6434 01
Plume displacement terminal kit i nc. 1m extensio n
10
and brackets
Plume displacement terminal kit i nc. 1m extensio n
11
and brackets
White 60mm 720627001
Black 60mm 720622901
White 60mm 7225717
Black 60mm 7225716
Key and OD dimensions
Key and OD dimensions
Sales code
Sales code
Vertical concentric flues Ø 60/100mm
Multifit Flue Group A
Item Description (multifit) flue system Colour Specification
12 Vertical flue terminal Black 100m m 5118576
3 1m flue extension inc. fixing screws White 1000mm 10 0mm 720648801
4 93° flue bend inc. fixing screws White 93° 100 mm 720648401
5 135° flue ben d inc. fixing screws (pair) White 135° 10 0mm 720647901
7
1
4
5
(x2)
2
6
3
12
9
8
Key and OD dimensions
10
Sales code
11
9
Page 10
You asked for it...
15 and 18kW
28kg lift weight
Compact cupboard fit
Front access to all components
Central top flue
Optional stand-o frame
10
Key features Benefits
5 Year Warranty
Outputs 15kW and 18kW To suit most property sizes
Compact cupboard fit Can be installed discreetly
Lightweight 28kg lift weight
Front access to all components Saves time when servicing, allowing for ease of maintenance and repair
Fully modulating and highly ecient Boiler intelligently uses the right amount of fuel to meet the set
Central top flue For ease of replacement
Flueing options of up to 20m Allowing greater flexibility of siting
Ease of service No special tools or replacement seals required for standard service
Vertical packaging Easy to transport and unpack
Clean aesthetic finish Boiler casing hides system connections for cleaner finish
For peace of mind
central heating temperatures, saving money on fuel bills
Page 11
Main Eco
Compact System
The new cupboard fit Main Eco Compact System boiler is the perfect choice for homes with more than one bathroom, to satisfy all its hot water needs.
It is easy to install and service, with front access to all components and central top flue, while its five year warranty, good looks and simple controls make it the perfect choice for householders.
Compatible accessories
7649277
720644801
Baxi uSense wired
Baxi programmable
smart thermostat
7-day wireless sensor (2 channel)
Subject to registration and an annual service. Terms and conditions apply. Visit baxi.co.uk/warranty
720971601
Baxi wired room thermostat
11
Page 12
MAIN ECO COMPACT SYSTEM
Technical specifications
Dimensions and minimum clearances
Boiler dimensions
Width [A] Height [B] Depth [C]
390mm 700mm 285mm
Service clearances
A
DD
E
B
Side [D] Upper [E] Lower [F] Front [G]
5mm* 178mm* 200mm* 5mm*
*450mm for servicing
Included with the Main Eco Compact System
Bracket
G
Literature and fitting pack
F
Copper pipe tails
C
12
Page 13
Main Eco Compact
Main Eco Compact System Units
Sales code (boiler only) 7714 605 7714 606
System 15kW
Main Eco Compact
System 18kW
Controls
Reset switch Yes Yes
User adjustable CH temperature Yes Yes
LED operating status display Yes Yes
Gas
Natural Gas Yes Ye s
Nominal inlet supply pressure mbar 20 20
Maximum gas rate m3/hr 1.64 1.96
Heat input central heating (CH)
Heat output CH non-condensing
Heat output CH condensing
kW max gross (QnHs)
kW max (Pn)
kW min gross (QnHs)
kW min (P n)
kW max (Pnc)
kW min (P nc)
17. 16
5.15
15.00
4.50
16.2
4.9
20.60
5.15
18.00
4.50
19.4
4.9
ErP product information
NOx class 6 6
Sound power level, indoors L
Space heating eciency class A A
dB 49 51
WA
Electrical
Electrical supply Volts/Hz 230/50 230/50
Permanent live required Yes Yes
Switched live Yes Yes
Power consumption Watts 46 56
External fuse rating Amps 3 3
Internal fuse rating F2HA250V F2HA250V
Boiler IP rating (electrical protection) Approval category IPX5D IPX5D
Integral ‘boiler only’ frost thermostat Yes Yes
Pump overrun Yes Yes
Mechanical
Temporary filling loop – optional (248221)
Wall mounting jig Yes Ye s
Isolating valves Yes Ye s
Gas supply connection mm 22 22
Central heating connections mm 22 22
Condensate drain connection mm 21.5 21.5
Safety discharge connection mm 15 15
Hydraulic
Safety discharge pressure bar 3 3
Integral automatic bypass Yes Yes
Integral expansio n vessel litres 7 7
Maximum capacit y of CH system litres 100 100
24hr pump exercise Yes Ye s
Pump overrun Yes Ye s
Concentric flue systems
Concentric flue diameter mm 60/100 and 80/ 125
Standard horizontal flue kit length (ø 60/100) mm 685 685
Maximum equivalent vertical length (ø 60/100) m 10 10
Maximum equivalent vertical length (ø 80/125) m 20 20
Equivalent length per 135° bend m 0.50 0.50
Equivalent length per 93° bend m 1 1
Weights
Gross packaged boiler weight kg 31.2 31.2
Maximum installation lift weight kg 28.06 28.06
13
Page 14
MAIN ECO COMPACT SYSTEM
Electrical Power
Terminal
Pressure Gauge
What’s inside?
Overheat Thermostat Sensor
Expansion vessel
top up valve
Flue
Burner Mixing Chamber
Stainless Steel Heat Exchanger
Fan
Water Pressure Sensor
Combustion
Checking Points
Ignition and
Flame Sensing
Electrode
Air Inlet Silencer
Expansion
Vessel
Pump
14
Condensate Drain
Electrical Power Terminal
Gas Valve
Pressure Gauge
Page 15
Flue solutions
Horizontal concentric flues Ø 60/100mm
Multifit Flue Group A
Item Description (multifit) flue system Colour Specification
Horizontal telescopic flue inc. low profile elbow
1
and fixing screws
Horizontal telescopic flue inc. low profile elbow
2
and fixing screws
3 1m flue ex tension inc. fixing screws White 1000mm 100mm 720648801
4 93° flue bend inc. fixing screws White 93° 100mm 720648401
5 135° flue ben d inc. fixing screws (pair) White 135° 100mm 720647901
Standard horizontal flue inc. low profile elbow
6
and fixing screws
White pipe/white
terminal
White pipe/black
terminal
White pipe/black
terminal
315mm – 500mm 100mm 720599401
315mm – 500mm 100mm 720598701
685mm 100m m 7222019
Plume displacement kits Ø 60/100mm
Multifit Flue Group A
Item Description (multifit) flue system Colour Specification
Plume d isplacement ter minal kit for tel escopic flue
7
inc. 1m e xtension and b rackets
Plume d isplacement ter minal kit for tel escopic flue
8
inc. 1m e xtension and b rackets
9 Plume displacement kit extension and brackets White 1000mm 60mm 720 6434 01
Plume displacement terminal kit i nc. 1m extensio n
10
and brackets
Plume displacement terminal kit i nc. 1m extensio n
11
and brackets
White 60mm 720627001
Black 60mm 720622901
White 60mm 7225717
Black 60mm 7225716
Key and OD dimensions
Key and OD dimensions
Sales code
Sales code
Vertical concentric flues Ø 60/100mm
Multifit Flue Group A
Item Description (multifit) flue system Colour Specification
12 Vertical flue terminal Black 100m m 5118576
3 1m flue extension inc. fixing screws White 1000mm 10 0mm 720648801
4 93° flue bend inc. fixing screws White 93° 100 mm 720648401
5 135° flue ben d inc. fixing screws (pair) White 135° 10 0mm 720647901
7
1
4
5
(x2)
2
6
3
12
9
8
Key and OD dimensions
10
Sales code
11
15
Page 16
You asked for it...
15, 18 24, 30kW
O n ly 17.4 kg
*
Positive fix wall mounting plate
Top central flue
No pump overrun
No permanent live
Front and side access
16
Key features Benefits
5 Year Warranty
Outputs 15kW, 18kW, 24kW and 30kW To suit most property sizes
Only 17.4kg installer lift weight* The lightest boiler available in the UK**
Compact cupboardt Can be installed in a 290mm deep cupboard
Easy fit wall mounting bracket Robust with a positive fix and audible lock so you know it's secure
No pump overrun or permanent live required Saves time and money during installation, and less disruption for the householder
Front and side access Servicing is easier and quicker, and no special tools are required
Top centralue Easy replacement for existing boilers
Industry leading choice of flue lengths, bends and accessories
*30kW is 19.5kg installer lift weight **As at April 2019
For peace of mind
Extensive flue option up to 20 meters for versatile siting and easy replacement
Page 17
Main Eco
Compact Heat
The lightweight Main Eco Compact Heat is small enough to fit into a cupboard and is perfect for replacing old, standard eciency boilers.
Compatible accessories
7649277
7212443
Baxi uSense wired
Twin channel wired
smart thermostat
programmer
720971601
Baxi wired room thermostat
Subject to registration and an annual service. Terms and conditions apply. Visit baxi.co.uk/warranty
17
Page 18
MAIN ECO COMPACT HEAT
Technical specifications
Dimensions and minimum clearances
Boiler dimensions
Width [A] Height [B] Depth [C]
370mm 625mm 270mm
Service clearances
A
DD
E
B
Side [D] Upper [E] Lower [F] Front [G]
5mm* 190mm* 120mm* 5mm*
*500mm for servicing
Included with the Main Eco Compact Heat
Top flue adapter
G
Literature and fitting packBracket
F
Power lead
Copper tail (gas connection) and fibre washer
C
18
Page 19
Main Eco Compact
Main Eco Compact Heat Units
Sales code (boiler only) 7712025 7712026 7712028 7712029
Heat 15kW
Main Eco Compact
Heat 18kW
Main Eco Compact
Heat 24kW
Main Eco Compact
Heat 30kW
Controls and accessories
Operating mode selector switch with reset Yes Yes Yes Yes
User adjustable CH temperature
LED temp/status/ fault diagnosis display Yes Yes Yes Yes
Twin channel wired programmer
Wired room thermostat (optional accessory)
Range 45°C to 82°C
721 2443
720971601
Yes Yes Yes Yes
Optional Optional Optional Optional
Optional Optional Optional Optional
Gas
SAP 2009 Annual Eciency (PCDB/SEDBUK)
NOx class
1-5
%
89% 89% 89% 89%
5 5 5 5
ErP product information
NOx mg/kWh 20 21 24 24
Sound power level, indoors L
Space heating eciency class A A A A
Heat input central heating (CH)
Heat output CH (non-condensing)
Gas supply pipe size
Inlet supply pressure (natural gas) mbar 20 20 20 20
Maximum gas rate m3/hr 1.75 2.07 2.73 3.27
kW max gross (QnHs)
kW max (Pn)
dB 33 34 37 37
WA
kW min gross (QnHs)
kW min (P n)
mm
18.32
8.59
16
7.5
22 22 22 22
21.75
8.59
19
7.5
28.62
8.59
25
7.5
34.35
8.59
30
7.5
Mechanical and hydraulic
Compartment ventilation required No No No No
Flow/return pipe mm 22 22 22 22
Condensate discharge pipe connection mm 21.5 21.5 21.5 21.5
Electrical
Electrical supply Volts / Hz 230V / 50Hz 230V / 50Hz 230V / 50Hz 230V / 50Hz
Permanent live required No No No No
Power consumption Watts 20 23 33 44
External fuse rating Amps 3 3 3 3
Internal fuse rating 1.6T 1.6T 1.6T 1.6T
Boiler IP rating (electrical protection) Approval Category IPX4D IPX4D IPX4D IPX4D
Pump overrun No No No No
Concentric flue systems
Standard telescopic concentric flue mm 315-500 315-500 315-500 315-500
Horizontal concentric (60/100mm)
Max equivalent length (m) 6 6 6 6
Reduc tion Per 135º bend (m) 0.5 0.5 0.5 0.5
Reduc tion Per 93º ben d (m) 1 1 1 1
Horizontal concentric (80/125mm) m 12 12 12 12
Weights
Gross packaged boiler weight (Max)kg 19.5 19.5 19.5 21.5
Maximum installation lift weight kg 17.4 17. 4 17.4 19.5
19
Page 20
MAIN ECO COMPACT HEAT
Slide out product I.D /
serial no. plate
Controls
Drain point
Integrated HMI
cover
What’s inside?
Flow and return pipes
Fan assembly
Spark electrode
Air inlet silencer
Condensate trap (not visible)
Flue connection from the top
Pressure switch
Burner
PCB housing
Aluminium heat
exchanger
Gas Valve
Data cable
Drain point
Slide out product I.D / serial no. plate
Controls
Integrated HMI
cover
20
Page 21
Flue solutions
Horizontal concentric flues Ø 60/100mm
Multifit Flue Group A
Item Description (multifit) flue system Colour Specification
Horizontal telescopic flue inc. low profile elbow
1
and fixing screws
Horizontal telescopic flue inc. low profile elbow
2
and fixing screws
3 1m flue ex tension inc. fixing screws White 1000mm 100mm 720648801
4 93° flue bend inc. fixing screws White 93° 100mm 720648401
5 135° flue ben d inc. fixing screws (pair) White 135° 100mm 720647901
Standard horizontal flue inc. low profile elbow
6
and fixing screws
White pipe/white
terminal
White pipe/black
terminal
White pipe/black
terminal
315mm – 500mm 100mm 720599401
315mm – 500mm 100mm 720598701
685mm 100m m 7222019
Plume displacement kits Ø 60/100mm
Multifit Flue Group A
Item Description (multifit) flue system Colour Specification
Plume d isplacement ter minal kit for tel escopic flue
7
inc. 1m e xtension and b rackets
Plume d isplacement ter minal kit for tel escopic flue
8
inc. 1m e xtension and b rackets
9 Plume displacement kit extension and brackets White 1000mm 60mm 720 6434 01
Plume displacement terminal kit i nc. 1m extensio n
10
and brackets
Plume displacement terminal kit i nc. 1m extensio n
11
and brackets
White 60mm 720627001
Black 60mm 720622901
White 60mm 7225717
Black 60mm 7225716
Key and OD dimensions
Key and OD dimensions
Sales code
Sales code
Vertical concentric flues Ø 60/100mm
Multifit Flue Group A
9
Key and OD dimensions
Sales code
10
11
Item Description (multifit) flue system Colour Specification
12 Vertical flue terminal Black 100m m 5118576
3 1m flue extension inc. fixing screws White 1000mm 10 0mm 720648801
4 93° flue bend inc. fixing screws White 93° 100 mm 720648401
5 135° flue ben d inc. fixing screws (pair) White 135° 10 0mm 720647901
7
1
4
5
(x2)
2
6
3
8
12
21
Page 22
Flue solutions
Multifit flue kits now come with positive screw fixings for all connections and are available in a choice of lengths to reduce the need for onsite cutting. By popular demand we oer a choice of colours for the terminals to match existing rainwater systems.
The options shown are only compatible with Main Heating Eco Elite Combi and System.
Maximum recommended flue lengths
Main Combi / System A (60/100 Concentric) G (80/125 Concentric)
Horizontal 10 20
Vertical 10 20
Horizontal concentric flues Ø 60/100mm
Multifit Flue Group A
Item Description (multifit) flue system Colour Specification
1 Horizontal telescopic flue inc. low profile elbow and fixing screws
2 Horizontal telescopic flue inc. low profile elbow and fixing screws
3 Horizontal telescopic flue inc. low profile elbow and fixing screws
4 Stan dard horizontal flue inc. low profile elbow and fixing screw s*
6 Flue terminal deflector White 60mm 72064 4201
7 Flue terminal deflector Black 60mm 5111068
8 Flue terminal deflector Brown 60mm 720644301
9 1m flu e extension inc. fixing screws White 1000mm 100mm 720648801
10 0.5m flue extension inc. fix ing screws White 500mm 100mm 720643001
11 0.25m flue extensio n inc. fixing screws White 250mm 100mm 720 643101
12 93° flue bend inc. fi xing screws White 93° 100mm 720648401
13 135° flue b end inc. fixing screws White 135° 100mm 720648501
14 135° flue bend inc. fixing screws (pair) White 135° 100mm 720647901
17 Stainless steel terminal guard – Ø 60/100 S/S Stainless steel 100mm 720627901
White pipe/ white terminal White pipe/ black terminal White pipe/ brown terminal White pipe/ black terminal
315mm – 500mm 60/ 100mm 720599 401
315mm – 500mm 60/ 100mm 720598701
315mm – 500mm 60/ 100mm 720642701
685mm 100mm 7222019
Key and OD dimensions
Sales code
22
Plume displacement kits Ø 60/100mm
Multifit Flue Group A
Item Description (multifit) flue system Colour Specification
18 Plume displacement termin al kit inc. 1m extension and brackets White 60mm 7206270 01
19 Plume displacement kit extension and br ackets White 1000mm 60mm 7206 43401
20 Plume displacement kit bend White 93° 60mm 5121369
21 Plume displacement kit bend – pa ir White 135° 60mm 5121370
22 Plume displacement terminal kit inc. 1m ex tension and bra ckets Black 60mm 720622901
23 Plu me displacement kit extensi on and brackets Black 1000mm 60mm 720643301
24 Plume displacement kit bend Black 93° 60mm 720648701
25 Plume displacem ent kit bend – pair Black 135° 60mm 720648601
26 Plum e displacement terminal kit in c. 1m extension and brackets White 100mm 7225717
27 Plume displace ment terminal kit inc. 1m extension and brackets Black 100mm 7225716
28 Under balcony eaves flue kit White 135° 60mm 7211039
29 Under balcony eaves flue kit Black 135° 60mm 7211041
For information on reductions for the twin pipe flues please see the installation instructions.
Key and OD dimensions
* Not compatible with items 16 and 20.
** Compatible wit h 1. *** Compatible with 22.
Sales code
Page 23
Vertical concentric flues Ø 60/100mm
Multifit Flue Group A
Item Description (multifit) flue system Colour Specification
30 Vertical ridge flue terminal Brown 100mm 7 20647101
31 Vertical flue terminal Black 10 0mm 5118576
32 Roof cover plate 125mm 246 143
9 1m flu e extension inc. fixing screws White 1000mm 100mm 720648801
10 0.5m flue extension inc. fix ing screws White 500mm 100mm 720643001
11 0.25m flue extensio n inc. fixing screws White 250mm 100mm 720 643101
12 93° flue bend inc. fi xing screws White 93° 100mm 720648401
13 135° flue b end inc. fixing screws White 135° 100mm 720648501
14 135° flu e bend (pair) in c. fixing screws White 135° 100mm 720647901
33 Pitched roof flashing 25°/ 50° 125mm 5122151
34 Flat roof flashing 125mm 246 144
9
10
11 12
4
1
2
3
Key and OD dimensions
Sales code
6
20 24
182822
13
14
32
(x2)
(x2)
25
17
30
7
8
19 23
262127
29
33
31
34
23
Page 24
Flue solutions
Horizontal concentric flues Ø 80/125mm
Multifit Flue Group G
Item Description (multifit) flue system Colour Specification
35 Horizontal flue inc. boiler and terminal adaptors Black 125mm 511858 0
36 1m flue exten sion White 1000mm 125mm 51185 84
37 Flue bend White 91.5° 125mm 5118588
38 Flue bend ( pair) White 135° 125mm 5118597
39 Pipe support bracket White 125mm flue pipes 125mm 5118610
Vertical concentric flues Ø 80/125mm
Multifit Flue Group G
Item Description (multifit) flue system Colour Specification
40 Vertical flue terminal Black 125mm 5111078
36 1m flue exten sion White 1000mm 125mm 51185 84
37 Flue bend White 91.5° 125mm 5118588
38 Flue bend ( pair) White 135° 125mm 5118597
41 Flue vertical adaptor White 100/125mm 5111070
33 Pitched roof flashing 25°/55° 125mm 5122151
35 Flat roof flashing 125mm 246144
39 Pipe support brackets White 125mm flue pipes 125mm 5118610
Key and OD dimensions
Key and OD dimensions
Sales code
Sales code
39
35 36 37
38
(x2)
41
The options shown are only compatible with Main Heating Eco Elite Combi and System.
24
Page 25
N
I
I
G
F
M
I
A
A
F
H
J,K
D E
H
C
R
A
I
J,K
I
L
S
B
T
U
Likely flue positions requiring a flue terminal guard
Terminal position with minimum distance (mm)
A1 Directly below an opening, air brick, opening windows etc 300
1
B
Ab ove an opening , air brick, op ening window etc 300
1
C
Horizontally to an opening, air brick, opening window etc 300
2
D
Below gutters, s oil pipes or drain pipes 25
2
E
Below eaves 25
2
F
Below balconies or c ar port roof 25
2
G
Fro m a vertical drain pipe or soil pipe 25
2
H
From an internal or external corner 25 I Above ground, roof or balcony level 300 J From a surf ace or boundar y line facing a ter minal 600 K From a terminal facing a terminal (Horizontal flue) 1200 K From a terminal facing a terminal ( Ver tical flue) 600 L Fro m an opening in a ca rport (e.g. door, window) into th e dwelling 1200 M Vertically from a terminal on the s ame wall 1500 N Horizontally from a terminal on th e same wall 300 R From adjacent wall to flue (vertical only) 300 S From an a djacent opening window (ver tical only) 300 T Ad jacent to windows or openings o n pitched and flat roofs 600 U Below windows or openings on pitched roofs 2000
1. In addit ion, the terminal should be no nearer tha n 150mm to an
opening in the building fabric formed for the purpose of accommodating a built-in element such as a window fr ame.
2. Only ONE 25mm clearan ce is allowed per installation . If one of
the dimensions D, E, F, G or H is 25mm then the remainder MUST be as B.S.5440-1.
Plume displacement kit
IMPORTANT:
If fitting a Plume Displacement Flue Kit, the air inlet must be a minimum of 150mm from any opening windows ordoors
Terminal assembly
Top view rear flue
300mm
min*
Air inlet
Opening window
NOTE:
or door
The distance from a fanned draught appliance terminal installed parallel to a boundary may not be less than 300mm in accordance with the diagram.
Property boundary line
150mm min.
* This can be reduced to 25mm by using item 6/ 7/8 flue d eflector.
25
Page 26
MAIN UNVENTED CYLINDER
B
26
Key features Benefits
One year parts and labour warranty plus 25 year warranty on stainless steel inner vessel
120, 150, 170, 210, 250 and 300 litre capacity – direct and indirect types
Indirect heating coil is factory fitted with an electric immersion heater as back up
Coil in coil heat exchanger Ensures rapid, energy ecient heat recovery
Incoloy 800 alloy sheathed elements Designed to resist corrosion
KIWA approved Complies with water regulations and
50mm of polyurethane foam insulation Minimum heat loss and maximum eciency
For peace of mind
A cylinder for every style and size of property, to meet all hot water demands
Hot water whenever it is needed
Building Regulation G3
Page 27
Main
Unvented Cylinder
Manufactured in the UK, the Main Unvented Hot Water Cylinder is easy to install, with front access to controls and connections. The coil-in-coil heat exchanger ensures rapid heat recovery and 50mm of factory injected polyurethane foam ensures that heat loss and running costs are kept to a minimum. The inner cylinder is made from high grade stainless steel for a long product life with low maintenance.
The Main Cylinder, together with a Main Eco Compact System boiler or Main Eco Elite System boiler, provides a complete solution for homes with a high demand for hot water.
Subject to registration and an annual service. Terms and conditions apply. Visit baxi.co.uk/warranty
27
Page 28
MAIN UNVENTED CYLINDER
25°
45°
30°
45°
595
Ø
550
Technical specifications
Dimensions and minimum clearances
HOT OUTLET
T&P VALV E
Ø
A
550
B
PRIMARY FLOW
COLD INLET
PRIMARY RETURN
315
354 - indirect
306 - direct
Nominal Capacity (litres)
120 931 616 121 C 720635901
120
150
150
170
170
210
210
250
250
300
300
Type
Direct Indirect
Dimensions
A (mm)
Dimensions
B (mm)
931 616 12.5 27 23 29 B 5133561
1114 800 152 C 720636001
1114 800 12.5 38 24 37 C 5133562
1241 927 173 C 720 636101
1241 927 16 33 25 35 C 5133563
1499 1184 215 C 720636201
1499 1184 16 41 29 43 C 5133564
1752 1437 260 D 720636301
1752 1379 18 40 30 43 D 5135327
2065 1751 315 D 720636401
2065 1694 19 47 35 49 D 5135328
Rating
kW
Coil Heat
Up Time
(mins)
Recovery
Times
Heating
45°
Time
Direct
(mins)
25°
Rating
ErP
30°
45°
Product
Code
595
Standing Heat Loss (kW/h per
24hr)
1.47
1.7
1.92
2.3
2.22
2.52
28
Page 29
Installation
Main unvented cylinders must be installed by a competent installer in accordance with local regulations:
England and Wales – Building regulation G3.
Scotland – Technical standards P3.
N. Ireland – Building regulation P5.
Element
Long-life removable Incoloy 800 sheathed element, rated 3.0kW @ 240V. Direct models are fitted with two
3.0kW immersion heaters as standard.
Outer casing
A combination of resilient thermoplastic mouldings and plastic coated corrosion proofed steelsheet.
Fixing – Feet on bottom moulding for floor mounting.
Plumbing connections – Inlet/Outlet, 22mm compression fittings / ¾” BSP
parallel thread.
Primary coil – 22mm compression fittings / ¾” BSP parallel thread.
Temperature and pressure relief valve – 15mmcompressionoutlet.
Cold water control – Integrated cold water control set comprising pressure
reducing valve and strainer – factory set at 3.5 bar, expansion relief valve – factory set at 6 bar and check valve. 22mmcompression fittings.
Mains pressure – Min 1.5 bar, Max 16 bar. A 2-port motorised valve is supplied with indirect models.
Flow rates – Up to 55 litres per minute @ 6 bar pressure.
Operating pressure – 3.5 bar.
Expansion relief valve pressure – 6.0 b ar.
Operating temperature – Recommended 60°C. Adjustable 10-70°C.
Water expansion – Remote expansion vessel
12 litre vessel supplied with 120 and 150 litre models. 18 litre vessel supplied with 170 and 210 litre models. 24 litre vessel supplied with 250 and 300 litre models.
Minimum water supply requirements – Recommended minimum supply pressure – 1.5 bar/20 l/min flow rate.
If there are any doubts about water supply pressure or flow rates, please contact our Specification Advice Team to discuss on0845026 4620.
Secondary circulation – Via 22 x 22 x 15mm swept tee, whichshould be fitted to the inlet pipework. Secondary Circulation is not recommended for direct units being used with o-peak electricity taris.
Pressure testing – Units are tested to 15 bar.
Tund ish – 15mm compression inlet and 22mm compression outlet.
Thermal insulation
CFC/HCFC free (ODP ZERO) fire retardant expanded polyurethane. 50mmthickness.
Inner container
Highgrade stainless steel, pressure tested to 15 bar.
Primary coil
22mm diameter stainless steel. Coil-in-coil design for improved performance.
Thermostat
Element thermostat adjustable from 10°C to 70°C.
Safety features
Temperature and pressure relief valve, factory set tooperate at 10 bar and 90°C. High limit thermostat,factory set at 80°C. Direct models – Manually re-settable cut-out on heating element operates at 80°C.
Indirect models
Must be wired in series with the supplied two-portmotorised valve to provide primary over temperature protection.
Electrical
Indirect models – Controls should be wired to the boiler, programmer etc., in accordance with the control scheme being used.
Direct models – Connection is direct to terminals in the immersion heater which must be permanently connected to the supply through a double-pole lined isolating switch with a minimum breaking capacity of 13A.
All electrical wiring must conform to the latest IEE Wiring Regulations.
Anode
None required.
Approvals
KIWA approved forwater regulations and building regulation G3. Manufactured in the UK in a BS EN ISO 9001:2008 registered factory. CE marked for compliance with LVD, EMC andpressure equipment directives.
29
Page 30
Controls and accessories
The range of Main Eco Compact controls that can be fitted quickly and simply.
720971601
Baxi wired room thermostat
720644801
BAXI programmable 7-day wireless sensor (2 channel) (twin channel programmer for system)
7212444
Baxi single channel wired programmer
7649277
Baxi uSense wired smart thermostat
7212438
Baxi single channel wired programmable thermostat
7683084
Baxi IFOS In Flue Outdoor Sensor Kit
720030701
MAIN RF digital 7-day programmable roomstat
7703233
On wall outdoor sensor
30
7715591
Main Eco Compact pre-plumb jig
248221
Multifit filling loop
7665482
Multifit Easy-Fill
Page 31
Notes
31
Page 32
Notes
32
Page 33
33
Page 34
How we can help
Baxi Customer Support
• Team of experts with products at hand to support installation, service and repair
• Further technical support and how-to videos available at baxi.co.uk
Call us on 0344 871 1525
Baxi Genuine Parts
• Approved parts for Baxi products
• Guaranteed quality, safety and reliability
• Nationwide network of approved stockists
• Lifetime support for Baxi products
• Range of heating essentials available
Call our knowledgeable and helpful team on 0344 871 1540 or visit www.baxi.co.uk/trade/boilers-parts-and-accessories/parts to identify parts and find your nearest stockist
Training
• Practical, hands on training
• Free of charge product training
• A range of specialist courses
• Expert trainers, all accredited, former heating engineers
• Training centres across the UK
34
Visit baxi.co.uk/training or call 0344 335 4207
Page 35
Baxi Works
Sign up to Baxi Works, Baxi’s online loyalty scheme for installers. Benefits include:
• Same or next day engineer call out from Baxi Customer Support*
• Free Gas Safe notification and easy warranty registration
• Scan your barcodes using the Baxi Toolbelt App
• Free annual service reminders sent to your customers on your behalf
• Free listing on baxi.co.uk to receive homeowner leads
• Earn points for every boiler you register
Visit baxiworks.co.uk to find out more
Events
Visit Baxi Area Sales Managers at your local merchant for an opportunity to get your hands on the latest Baxi boilers and discuss developments in the heating industry.
For more information visit baxievents.co.uk
Literature
You can order all the literature you need for you and your customers, including:
• Range guides
• Product brochures for consumers
• Installation instructions
• User guides
• Instructions for discontinued products
Call the Baxi literature hotline on 0344 871 1525 or contact your local Baxi Area Sales Manager.
All our literature can be downloaded from our website baxi.co.uk
* Full Baxi Works terms and conditions apply.
35
Page 36
0344 871 1525
Opening hours
Monday – Friday, 8am – 6pm Weekends and Bank Holidays, 8.30am – 2pm We are open 365 days a year.
Please note calls may be monitored or recorded.
mainheating.co.uk
info@mainheating.co.uk
Main Heating
Brooks House
Coventry Road
Warwick CV34 4LL
Follow us
Part of
This brochure is printed on paper sourced from well managed forests and other controlled sources, using vegetable based inks. Please recycle this brochure when yo u have finishe d with it.
Baxi p olicy is one of co ntinual imp rovement and d evelopment . The right to c hange specification and appearance without prior notice is reserved. Thereproduction of colours is as accurate as photographic and printing processes allow. The consumer’s statutory right s are not aecte d. E&OE
MainHeatingRangeGuideOct22
Loading...