![](/html/3d/3dca/3dcad93cfd0d0d410511be6e2cebd1788189d17878c5d83516b2548ad5dbcc00/bg1.png)
OperatingManual
Pleasereadcarefullyprior
toinstallationandservicing.
SAVETHESEINSTRUCTIONS
PE149USA4.1
PELLETBOILER
PE12–32
CMP0.62B–US_ST610
ENGLISH—USA
downloadfrenchversion:
www.maineenergysystems.com/manuals.htm
![](/html/3d/3dca/3dcad93cfd0d0d410511be6e2cebd1788189d17878c5d83516b2548ad5dbcc00/bg2.png)
Title:
OperatingManualPE12-32
Itemnumber:
Numberofversion:
Versionvalidfrom:11/2012
Author:
PE149USA4.1
04.01
MAINEENERGYSYSTEMSLLC
8AirportRoad–P .O.Box547Bethel
Maine04217
e-mail:info@maineenergysystems.com
web:www.maineenergysystems.com
©MAINEENERGYSYSTEMSLLC
Subjecttomodications
![](/html/3d/3dca/3dcad93cfd0d0d410511be6e2cebd1788189d17878c5d83516b2548ad5dbcc00/bg3.png)
Contents
1DearCustomer...............................................................................................................................................4
2Useonlyforthepurposeintended.................................................................................................................5
3Typesofsafetywarningsign..........................................................................................................................6
4Warningsandsafetyinstructions...................................................................................................................7
4.1Basicsafetyinstructions.................................................................................................................................7
4.2Warningsigns................................................................................................................................................7
4.3Whattodoinanemergency...........................................................................................................................8
5Prerequisitesforinstallingapelletboiler.......................................................................................................9
5.1Guidelinesandstandardsforinstallingapelletboiler.......................................................................................9
5.2Boilerroom...................................................................................................................................................9
5.3Fluegassystem............................................................................................................................................10
5.4Safetysystems..............................................................................................................................................12
6Fuel................................................................................................................................................................13
6.1SpecicationforhighqualitypelletsasPFI(PelletFuelInstitut)........................................................................13
6.2Storingthepellets..........................................................................................................................................13
7Productdescription........................................................................................................................................14
7.1Thepelletboiler.............................................................................................................................................15
7.2Augerdeliverysystem....................................................................................................................................17
7.3Storagesystems............................................................................................................................................17
8Operatingthepelletboiler..............................................................................................................................18
8.1Operatingtheheatingsystem.........................................................................................................................18
8.2Descriptionofthecontrolpanel.......................................................................................................................18
8.3Descriptionoperatingdevice..........................................................................................................................19
8.4Settinglanguage,dateandtime.....................................................................................................................20
8.5Menuconguration........................................................................................................................................22
8.6Emptyingtheashpan....................................................................................................................................24
8.7Emptyingtheashbox....................................................................................................................................25
9Maintenanceandservicing.............................................................................................................................27
9.1Maintenance.................................................................................................................................................27
9.2Cleaningtheboilereveryyear........................................................................................................................27
9.3Maintenanceintervals....................................................................................................................................30
9.4Repairs.........................................................................................................................................................30
9.5Checkingtheboilerroomandstorageroom....................................................................................................30
10Malfunctions.................................................................................................................................................31
PE149USA4.1
OperatingManualPE12-32
![](/html/3d/3dca/3dcad93cfd0d0d410511be6e2cebd1788189d17878c5d83516b2548ad5dbcc00/bg4.png)
DearCustomer
4
1DearCustomer
Wearespecialistinpelletheating,licensedbyÖkoFEN
Expertise,innovationandqualityfromasinglesource.Itisbasedonourtraditionthatwetakeonfuturechallenges.We
aredelightedthatalsoyouhavedecidedtopurchaseourproduct.
•Thisinstructionmanualisintendedtohelpyouoperatetheproductsafely,properly
andeconomically.
•Pleasereadthisinstructionmanualrightthroughandtakenoteofthesafety
warnings.
•Keepalldocumentationsuppliedwiththisunitinasafeplaceforfuturereference.
Pleasepassonthedocumentationtothenewuserifyoudecidetopartwiththe
unitatalaterdate.
•Duringinstallationand/orrststartuptheserviceengineermustcarryoutthe
followingwork.
•Theinstallationhastobeperformedbyaqualiedinstaller.
•Pleasecontactyourauthoriseddealerifyouhaveanyquestions.
Weplacegreatimportanceonthedevelopmentofnewproducts.OurR&Ddepartmentcontinuestoquestionaccepted
solutionsandworkscontinuallyonnewimprovements.Thatishowwemaintainourtechnologicallead.Wehavealready
receivedseveralawardsforourproductsinAustriaandabroad.
OurproductsfullEuropeanandUSArequirementsregardingquality,efciencyandemissions.
OperatingManualPE12-32
PE149USA4.1
![](/html/3d/3dca/3dcad93cfd0d0d410511be6e2cebd1788189d17878c5d83516b2548ad5dbcc00/bg5.png)
Useonlyforthepurposeintended
2Useonlyforthepurposeintended
Thepelletboilerisdesignedtoheatwaterforcentralorotherindirectheatingsystemsandhotwatersupplyforbuildings.
Itisnotpermissibletousethepelletboilerforanyotherpurpose.Reasonableforeseeableinadvertentusesforthe
pelletboilerarenotknown.
TheboilerfullstherequirementsofUL391,“StandardforSafetyforSolid-FuelandCombination-FuelCentraland
SupplementaryFurnaces,”2006,andCAN/CSA-B366.1–M91,“Solid-Fuel-FiredCentralHeatingAppliances”
OMNICerticate:
5
PE149USA4.1
OperatingManualPE12-32
![](/html/3d/3dca/3dcad93cfd0d0d410511be6e2cebd1788189d17878c5d83516b2548ad5dbcc00/bg6.png)
Typesofsafetywarningsign
6
3Typesofsafetywarningsign
Thewarningsignsusethefollowingsymbolsandtext.
Typesofsafetywarningsign
1.Riskofinjury
2.Consequencesofrisk
3.Avoidingrisk
1.Riskofinjury:
Danger-indicatesasituationthatcouldleadtodeathor
life-threatninginjury.
Warning-indicatesasituationthatcouldlead
life-threatningorseriousinjury.
Caution-indicatesasituationthatcouldleadtoinjury.
Note-indicatesasituationthatcouldleadtoproperty
damage.
2.Consequencesofrisk
Effectsandconsequencesresultingfromincorrect
operation.
3.Avoidingrisk
Observingsafetyinstructionsensuresthattheheating
systemisoperatedsafely.
OperatingManualPE12-32
PE149USA4.1
![](/html/3d/3dca/3dcad93cfd0d0d410511be6e2cebd1788189d17878c5d83516b2548ad5dbcc00/bg7.png)
Warningsandsafetyinstructions
4Warningsandsafetyinstructions
Observingsafetyinstructionsensuresthattheheatingsystemisoperatedsafely.
4.1Basicsafetyinstructions
•Nevergetyourselfintodanger;giveyourownsafetytheutmostpriority.
•Keepchildrenawayfromtheboilerroomandstorageroom.
•Observeallsafetywarningsontheboilerandinthisusermanual.
•Observeallinstructionsrelatingtomaintenance,servicingandcleaning.
•Thepelletheatingsystemmayonlybeinstalledandstartedupforthersttimebyanauthorisedinstaller.
Professionalinstallationandstartupistheprerequisiteforsafeandeconomicaloperation.
•Nevermakeanychangestotheheatingsystemoruegassystem.
•Nevercloseorremovesafetyvalves.
7
4.2Warningsigns
Riskofpoisoning
Makesurethatthepelletboilerissuppliedwithsufcient
combustionair.
Theopeningsinthecombustionairinletmustneverbe
partiallyorcompletelyclosed.
Ventilationsystems,centralvacuumcleaningsystems,
extractorfans,airconditioningsystems,uegasblowers,
dryersorsimilarequipmentmustneverbeallowedtodraw
airfromtheboilerroomandcauseadropinpressure.
Theboilermustbeconnectedtighttothechimneyusing
auegastube.
Cleanthechimneyandtheuegastubeatregularintervals.
Theboilerroomandpelletstorageroommustbesufciently
suppliedwithairandventilated.
Beforeenteringthestorageroomitmustbeventilatedwith
sufcientairandtheheatingsystemswitchedoff.
Riskofelectricshock
Switchoffthesystembeforeperformingworkontheboiler.
Riskofexplosion
DONOTBURNGARBAGE,GASOLINE,NAPHTHA,
ENGINEOIL,OROTHERINAPPROPRIATEMATERIALS.
DONOTUSECHEMICALSORFLUIDSTOSTARTTHE
FIRE.
Switchofftheheatingsystembeforellingthestorageroom.
PE149USA4.1
OperatingManualPE12-32
![](/html/3d/3dca/3dcad93cfd0d0d410511be6e2cebd1788189d17878c5d83516b2548ad5dbcc00/bg8.png)
Warningsandsafetyinstructions
8
Riskofre
Donotstoreanyammablematerialsintheboilerroom.
Donothangoutanywashingintheboilerroom.
Donotoperatewithfuelloadingorashremovaldoorsopen.
Riskofburns
Donottouchtheuespigotortheuegastube.
Donotreachintotheashchamber.
Useglovestoemptytheashbox.
Donotcleantheboilerbeforeitcooleddown.
HOTSURFACES
Keepchildrenaway .
Donottouchduringoperation.
Maximumdraftmarkedonnameplate.
Riskofcutinjuriesduetosharpedges.
Useglovesforperformingallworkontheboiler.
Damagetoproperty
HeattheAutopelletheatingsystemusingpelletsthat
complywithPFIpremiumspecicationsonly.
Damagetoproperty
Donotusetheheatingsystemifit,oranyofitscomponents,
comeintocontactwithwater.
Ifwaterdamageoccurs,checktheheatingsystembyan
authorizedservicetechnicianandreplacedamagedparts.
4.3Whattodoinanemergency
Exhaustgascauseasphyxiationandendangerlife
Nevergetyourselfintodanger;giveownsafetyutmost
priority.
WhattodointheeventofareWhattodoifyousmellsmoke
Exitthebuilding
CalltherebrigadeClosethedoorsleadingtolivingareas.
Switchofftheheatingsystem.
Useapprovedreextinguishers(reprotectionclass
ABC).
OperatingManualPE12-32
Switchofftheheatingsystem.
Ventilatetheboilerroom.
PE149USA4.1
![](/html/3d/3dca/3dcad93cfd0d0d410511be6e2cebd1788189d17878c5d83516b2548ad5dbcc00/bg9.png)
Prerequisitesforinstallingapelletboiler
5Prerequisitesforinstallingapelletboiler
Youmustfullthefollowingconditionsbeforeoperatingafullyautomaticpelletboiler.
5.1Guidelinesandstandardsforinstallingapelletboiler
Overviewofstandardsandguidelinesapplyingtotheinstallationofapelletboiler.
Checkwhetheryouneedtoobtainplanningpermissionorapprovalfromtheauthoritiesforinstallinganewheating
systemorchangingyourexistingsystem.Legislationinyourcountrymustbeobserved.
5.2Boilerroom
Thepelletboilerisinstalledintheboilerroom.
1.Safetyinstructionsfortheboilerroom
9
Riskofre
Donotstoreammablematerialsorliquidsinthevicinityof
thepelletboiler.
Donotpermitunauthorisedpersonstoentertheboilerroom
-Keepchildrenaway.
Donotoperatewithfuelloadingorashremovaldoorsopen.
2.Airsupplyandventilationofboilerroom
Theboilerroommustbettedwithairsupplyandventilationopenings(atleast31inch²/200cm²).Inanycase
youmustcomplywiththestateandlocalregulations
3.Combustionairsupply
Thepelletboilerneedsasupplyofcombustionair.Thesupplyofcombustionaircan:
a.takeplaceusingoneormoreairsupplyandventilationopeningsintotalmin.31inch²/200cm²
b.orthroughaspecialairsupplylinedirectlyfromoutside,wherethediameteroftheairsupplylinemustbeat
least4inch/100mminfortypePE(S)12–PE(S)32.AmbientairindependentoperationofPES36-56typesis
alsoavailableonrequest.
Neveroperatethepelletboileriftheairintakeopeningsarepartiallyorcompletelyclosed.
Contaminatedcombustionaircancausedamagetothepelletboiler.Neverstoreofusecleaningdetergents
containingchlorine,nitrobenzeneorhalogenintheroomwheretheheatingsystemisinstalled,ifcombustionair
isdrawndirectlyfromtheroom.Itisrecommendedthatnowashingordryingoflaundryisdoneintheboiler
roomorwheretheboilermaydrawairfrom.
Donothangoutwashingintheboilerroom.
Preventdustfromcollectingatthecombustionairintaketothepelletboiler.
4.Damageduetofrostandhumidair
Theboilerroommustbefrost-prooftoensuretrouble-freeoperationoftheheatingsystem.Thetemperatureof
theboilerroommustnotfallbelow37°Fandmustnotexceed90°F .Theairhumidityintheboilerroommust
notexceed70%.
5.Dangerforanimals
Makesurethathouseholdpetsandothersmallanimalscannotentertheboilerroom.Fitmeshoveranyopenings.
6.Flooding
Ifthereisariskofooding,switchoffthepelletboileringoodtimeanddisconnectfromthepowersupplybefore
waterenterstheboilerroom.Youmusthaveallcomponentsthatcomeintocontactwithwaterreplaced,beforeyou
startupthepelletboileragain.
PE149USA4.1
OperatingManualPE12-32
![](/html/3d/3dca/3dcad93cfd0d0d410511be6e2cebd1788189d17878c5d83516b2548ad5dbcc00/bga.png)
Prerequisitesforinstallingapelletboiler
10
5.3Fluegassystem
Theuegassystemconsistsofachimneyandauegastube.Theuegastubeconnectsthepelletheatingsystemto
thechimney .Thechimneyleadstheuegasfromthepelletheatingsystemoutintotheopen.
1.Designofthechimney
Thedimensionsanddesignofthechimneyisveryimportant.Thechimneymustbeabletoensuresufcientdraftto
safelydrawawaytheuegasregardlessofthestatusoftheboiler.Lowuegastemperaturescancausesooting
andmoisturedamageonchimneysthatarenotinsulated.Forthisreasonmoisture-resistantchimneys(stainless
steelorceramic)shouldbeused.Anexistingchimneythatisnotdamp-resistantneedstoberennovatedbefore
use.Followguidelinesbelow:
Boilersize
Fluegastubediameter(atboiler)inch/mm5/1306/1507/180
Fluegastemp./ratedpower°F
Fluegastemp./partialload°F
Min.draft–fullload/partloadin/wc0.03/0.01
Chimneysize
6in/150mmx6in/150mm17ft/5,2m
7in/180mmx7in/180mm16ft/4,8m
8in/200mmx8in/200mm16ft/4,8m
6in/150mmround19ft/5,8m
7in/180mmround17ft/5,2m
RecommendedandUL-103HTapprovedchimneymaterialsare:
a.Selkirksuretemp
b.Supervent(JSC)
c.Securitychimneys(securetempASHT)
Min.Height
PE(S)12–20PE(S)25–32PE(S)36–56
320320360
212212230
Useheavygauge(26gaorbetter)blacksmokepipetoconnecttoexistingchimney
Unregulatedcombustion
Pleaseobservethatcombustionairopeningsanduepipes
arenotreducedinsizeorclosed.Makeenduserawareof
theseguidelinesandtheirpotentialdanger.
Cleanthechimneyandtheuegastubeatregularintervals.
Checkifthedraftinduceriscleanandinagoodcondition.
2.Fluegastemperature
Theuegastemperaturesarethesameforallboilertypes:
Thedewpointofuegaswithwoodpellets(max.10%watercontent)isapprox.120°F .
Itispossibletoincreasetheuegastemperaturetopreventcondensationinsidethechimneyandavoiddamage
duetodamp.Onlyauthorisedspecialistpersonnelmayincreasetheuegastemperature.
Note
Theincreaseinuegastemperatureresultsinreducedefciencyandthusincreasesfuelconsumption.
OperatingManualPE12-32
PE149USA4.1
![](/html/3d/3dca/3dcad93cfd0d0d410511be6e2cebd1788189d17878c5d83516b2548ad5dbcc00/bgb.png)
Prerequisitesforinstallingapelletboiler
3.Negativepressureofthechimney
Theboilermustbeconnectedtoachimneyoraverticalventingsystemthatiscapableofhandlingandproducinga
negativebreechingpressureof–0.020“WC(-5Pa).Useadraftgaugetoverifytheindicateddraftvalue,adjust
barometricdamperasrequired.Drillasmallholeintheconnectionpipeatabout2in/50mmfromtheboilerue
outletandusethisholeasyourmeasuringpoint.
Chimneydraft
Thesuctioneffectofthechimneydraftmustextendasfarasthepelletboiler.Themaximum
owratethatcanbedrawnthroughthechimneylimitsthemaximumperformanceofthe
pelletboiler.Theboilerperformancemustbereducedifthechimneydoesnotpossessthe
necessarycross-section.Thismayonlybeperformendbyauthorisedpersonnel.
Toostrongachimneydraftincreasesheatlosswhile
idlingandreducestheefciencyoftheheatingsystem.
Werecommendinstallingachimneydraftregulator
(barometricdamper).Chimneydraftregulatorsareinstalled
directlyintotheuegastubeorchimney.
Yourstateandlocalregulationsmustbeobserved.
11
4.Powerventer
AutoPelletboilersareapprovedbythemanufacturerforinstallationwiththeFieldControls
SWGAFpowerventerwhichisapprovedforwoodpelletburningappliances.
BoilerinstalledwithSWGAFpowerventersmustfollowallmanufacturer´sinstallationsand
mustcomplywithallapplicablecodesfromagencieshavingauthorityovertheinstallation.
5.Cleaning
Cleantheuegastubeandchimneyregularly.
Riskofchimneyre
Creosote-formationandneedforremoval:Lowgasue
temperaturecancausecreosote.Thecreosotecondense
intherelativelycoolchimney.Asaresult,creosoteresidue
accumulatesontheuelining.Wheningnited,thiscreosote
makesahotre.Thechimneyandthechimneyconnector
shouldbeinspectedatleasttwicemonthlyduringthe
heatingseasontodetermineifacreosotebuilduphas
occurred.Ifcreosotehasaccumulateditshouldberemoved
toreducetheriskofachimneyre.
Oxidationofchimney
Donotusemetalbrushestocleanchimneysmadeof
stainlesssteel.
Yourstateandlocalregulationsmustbeobserved.
PE149USA4.1
OperatingManualPE12-32