Maier MHI-6500 Operating Instructions Manual

Thank you for your patronage. You have purchase a quality product with one year guarantee. Your satisfaction means every thing to us, and we hope to give you excellent service. In order to use this machine effectively, we suggest that you study this booklet carefully.
MAIN FEATURES
Long electrostatic dust collector
Powerful UV germicidal technology
Remote control provides, convenient use
Independent fan rapidly circulates indoor air
Negative ions and activated oxygen remove odors and smoke
No need to replace filter, easy for cleaning
90-degree rotation extends purification coverage
Use advanced ionic air movement technology
6500 IM.indd 16500 IM.indd 1 2008-5-9 2:05:072008-5-9 2:05:07
VOLTAGE
Do not put any object into the unit. High electrical voltage is generated inside the unit and any object inside may cause electric shock or other hazards. Keep out of reach of children.
To avoid overexposure to ultraviolet light, people must stay at least 30cm (one foot) away from the unit. Short durations of exposure at close proximity are safe.
Do not cover the appliance with cloth or other object. Blocking of the front or rear grill will cause malfunction.
Never stare at the UV lamp or place your face directly against the front or rear grill during operation.
Turn off all controls before unplugging unit from outlet.
Damaged power cord must only be replaced by qualified service personnel with the spare power cord provided.
To prevent electric shock, do not dismantle, repair
or modify this product. In case of malfunction
contact authorized maintenance center.
Do not use in places where flammable
and explosive materials are stored.
Do not place machine in the shower or places
where water may wet the machine to prevent
electric shock.
This instruction booklet describes the safety precaution to be observed
during operation and serious consequences from improper operation.
The content not only is suitable for this product but also suitable for
electric appliances in general.
TLE
This machine uses AC 230V/50Hz(Europe) or AC 100~120V/50~60Hz(USA/Japan). Over voltage may cause fire hazard or electric shock.
6500 IM.indd 26500 IM.indd 2 2008-5-9 2:05:192008-5-9 2:05:19
whole unit
control panel
Dust Collector
Dust Collector Button
Air Output Vent
Inbulit Fan
Front Grill
Air Intake Vent
Inbulit UV Lamp
Rear Grill
Bottom Stand
ON/OFF Power Switch
Names of Parts
FLOW
6500 IM.indd 36500 IM.indd 3 2008-5-9 2:05:232008-5-9 2:05:23
3
ROTATE Option
FUNCTION Option
TIME SETTING
1-hour 2-hour 4-hour 5-hour 6-hour 7-hour
Inside the unit there is a circulating fan and a U.V. lamp. The fan circulates and purifies room air while the U.V. lamp cleans and sterilizes air at the same time. The unit runs the following sequence of functions according to the number of times you press the FUNCTION button:
Fan ON / U.V OFF Fan OFF /U.V. ON Fan ON / U.V. On Fan OFF / U.V. OFF
Press the rotate button, the unit will rotate in 90-degree angle, swinging back and forth. Press again and the rotation will end.
Press the TIME SETTING button when the unit is ON. According to the number of times you press the button, the setting will run in the following sequence as indicated by the LED:
Remote Control
This appliance can operate using a remote control. A shelf for the remote control is provided at the top of the unit to avoid accidental loss. The operation of remote control: Each press on the buttons of the remote control results in "BEEP" sound of different lengths (short or long), which guide you to select your preferred working status of the machine.
Operation ON/OFF
Operation Setting Option
Negative oxygen ion Hi/Med/Lo options:
Press the NEGATIVE OXYGEN ION button, the unit will then release negative ion with ion concentration level according to the number of times you press (in a cycle of LO MED HI), as indicated by the LED. Under HI: the appliance continues to release negative oxygen ion. Under MED: the unit runs a cycle of operating 60 seconds then resting 60 seconds Under LO: the unit runs a cycle of operating 15 seconds then resting 105 seconds
Set-Up and Operation
Place the Unit at least 30cm from the wall and in a location where children cannot stare directly into the unit at a close range.
Plug into a grounded domestic outlet. Press the ON/OFF button to initiate operation and the LED turns solid blue. Press the ON/OFF button again to stop operation.
※ ※
Under MED and LO, negative oxygen ion is released alternately. Choose the proper operation setting according to room size and air pollution level.
ROTATE MODE
ON/OFF
TIMERO ION
ON/OFF MODE
OION
ROTATE
ON1 short Low1 short Fan ON, UV OFF:1 short ON:1 short
OFF2 longs Med2 shorts Fan OFF, UV ON2 shorts OFF1 long
High3 shorts Fan ON, UV ON3 shorts
Fan OFF, UV OFF1 long
TIMER
Hours to Stop 1 2 3 4 5 6 7
BEEP sound 1 short 2 shorts 3 shorts 4 shorts 5 shorts 6 shorts 7 shorts
6500 IM.indd 46500 IM.indd 4 2008-5-9 2:05:272008-5-9 2:05:27
Remove the Dust Collector by holding the button
at the top. Use mild detergent to wipe off the dust from
each of the collection bars, then rinse with clean water
and dry thoroughly. Wait until the dust collector is comp-
letely dry and then put it back into the unit. The dust
collector is not entirely inserted into the unit until a
"click" sound is heard.
Cleaning the Appliance
Cleaning the Metal Pointers
After a certain period of time, the zigzag-shape metal pointers that release negative ion will accumulate dust and dirt that
will lower the efficiency of the appliance. Please clean the metal pointers whenever the dust collector is cleaned.
Two cleaning plates with springs are provided at the top part of the dust collector. To clean the metal pointers using the
cleaning plates, hold the top button of the dust collector and then repeat the process of pulling the dust collector out and
pushing it back. The cleaning plates will scrape off the dust on the metal pointers as you move the dust collector up and down.
The interior of the appliance also accumulate dust. Before putting the dust collector back after cleaning, invert the entire unit
for a few times to get rid of the accumulated dust.
The exterior of the unit can be cleaned using mild detergent and then rinsing with clean water and dry.
Do not allow any liquid to enter the unit. Wait until the unit is completely dry before use.
Cleaning and Protection
Unplug the unit every time before cleaning
Clean the dust collector and the metal pointers every one or two weeks or whenever there is unusual sound during operation.
Otherwise the unit will discontinue due to excessive dust on the collector. In general, a thorough cleaning will resume the unit
to normal operation.
Cleaning the Dust Collection
Pull out the dust collecfor
Wipe the collector with
a piece of damp cloth
6500 IM.indd 56500 IM.indd 5 2008-5-9 2:05:382008-5-9 2:05:38
5
Replacing the UV Lamp
Lamps are effective for about 8,000 hours (about 12 months).
Replace earlier if there is no "blue glow" inside the housing.
Remove the cover by lifting up the cover and sliding the cover
upward (see fig.1 and fig.2). Softly turn the UV lamp and slide
it from its fixture. Replace with a new lamp of the same model.
The unit will not function while the dust collector is removed and/or the back cover is removed.
Always restore the dust collector and the back cover to their respective positions after cleaning.
fig.1 fig.2
Cleaning and Protection
6500 IM.indd 66500 IM.indd 6 2008-5-9 2:05:472008-5-9 2:05:47
6
Applicable Areas
SELF CHECK BEFORE REPAIR
The unit is applicable for any room with a size of 60 square meters. It can be used in bedroom, sitting room, office, hotel,
hospital etc. If the unit is to be used in a smaller room, you may prefer to have the power setting on medium or low.
In case of malfunction, please check the following table to solve the problems. If problems persist, please contact your distributor or
send to appointed maintenance center for repair.
MALFUNCTION
CAUSE SOLUTION
Operating indicator off,
machine stop operating
Electric plug falls off from
socket
Plug looses, doesn’t contact
well to the socket
Plug into electric socket
Plug into electric socket tightly
and completely
Operating stop midway
Operation period set by the
timer arrives its end
No malfunction, restart the unit or
reset the timer
Loud noise
Dust collector is fully filled
with dirt
Operate in humid area
Clean the dust collector
Place the machine to dry place
UV lamp is not lit
UV lamp is broken or out of service
Refer to page 5 of the manual and
replace new lamp
Television, radio signal
distorted or interfered.
Dust collector is fully filled
with dirt
Operate within 1 meter
from television set or radio
Clean the dust collector
Move the machine 1 meter away
from television set or radio
6500 IM.indd 76500 IM.indd 7 2008-5-9 2:05:532008-5-9 2:05:53
TECHNICAL SPECIFICATION
5 3
2
2
Rated voltage Europe AC 230V/50Hz
USA/Japan AC 100~120V/50~60Hz
Power consumption 25W
Negative ion output 5x10 /cm
MHI-6500
Germicidal Air
Purifier
Add. &Tel
Name
Name of the store & its add.
Date of Purchase
DMY
Period of Guarantee
One year from the date of purchase
Article Customer
Store
(3)
Date (s) on this guarantee and the purchase invoice is the evidence of one
year free maintenance.
MHI-6500
(1) All products of
pass the strict tests prior to leaving factory.Customers could,within one year from the date of purchase,enjoy free repair or replacement of parts presentation of this guarantee if it is attested by
our company that malfunctlon or damage to the device and/or parts occurs
under normal running condition.
(2) The guarantee does not cover the damages that are attributable to self dismantling and assembling, unauthorized operation not found in the
instruction, random change of power source and/or voltage artificial causes
and natural disaster.
DISTRIBUTED BY.
Model number MHI-6500
Active oxygen output 0.05ppm
UV Spectrum
20 w/cm (at 10cmdistance)
Dimensions 200 x 267 x 760mm
Weight4350g
Applicable Area60m

maier
maier
6500 IM.indd 86500 IM.indd 8 2008-5-9 2:05:582008-5-9 2:05:58
Loading...