Maico EV 31, EVR 31, EVH 31 Mounting And Operating Instructions

Page 1
D
GB
F
Fensterventilatoren Window Fans Ventilateurs de fenêtre
EV 31 EVR 31 EVH 31
Montage- und Betriebsanleitung Mounting and operating instructions Instructions de montage et mode d’emploi
www.maico-ventilatoren.com
Page 2
2
Page 3
10
EV 31, EVR 31 and EVH 31
Scope of delivery
I nternal housing, complete
Connecting flange
External grille
Assembly instruction
Accessori es
Table of contents
Scope of delivery ........................................ 10
1. Warning symbols .................................. 10
2. Product information .............................. 10
Equipment overview ............................. 10
Product desc ription............................... 11
3. Technical Data ..................................... 11
Dimensions and weight ........................ 11
Rated voltage a nd frequency................ 11
4. Environmental conditions and
operating limits ..................................... 11
5. Essential safety instructions ................. 11
General safety instructions ................... 11
Intended use ........................................ 1 1
Predictable misuses ............................. 11
Safe and correct practices during
operation .............................................. 12
6. Installation preparation ......................... 12
Installat ion in windows .......................... 12
Installation in walls and wooden panels 12 Dismantling internal housing with
connecting f lange ................................. 12
7. Installation ............................................ 13
Installat ion in windows .......................... 13
Installation in walls and wooden panels 13
Electrical connection ............................ 14
Internal housing installation .................. 14
8. Operation ............................................. 15
9. Maintenance......................................... 15
With fans in swivel windows ................. 15
10. Cleaning ............................................... 15
11. Dismantling ventilation unit ................... 15
12. Fault rectification .................................. 16
13. Spare parts........................................... 16
14. Disposal ............................................... 16
Wiring diagram ........................................... 25
1. Warning symbols
DANGER
Danger to life
Non-observance can lead to death or seri ous bodily injuries.
WARNING
Danger of injury
Non-observance can lead to serious bodi ly injuries
CAUTION
Danger of injury
Non-observance can lead to minor or more serious bodily injuries.
NOTICE
Property damage.
Non-observance can lead to damage to proper ty.
2. Product information
Equipment overview, Figure A
1 Internal housing, complete
EV 31, EVR 31: With electric al internal shutter EVH 31: Internal shutter with pull-cord
for manual operation 2 Screw 3 Connecting flange
3.1 Locking hook 4 Window pane 5 Cable grommet 6 Capacitor 7 Window pane ring 8 External grille
8.1 Housing dome 9 Connection t erminal socket 10 Window pane ring 11 Ball 12 Connection terminal plug 13 Catch 14 Impeller 15 Motor 16 EVH 31: Pull-cord X Rating plate
Imprint: © Maico Elektroapparate-Fabrik GmbH. E & OE. We reserve the right to make technical modifications.
GB
Page 4
11
Product description Wiring diagram, see page 25
EV 31 with electrical internal shutter. For air extraction. Speed controllable. On/of f with light switch or separate switch (al l to be supplied by c ustomer). The fan unit switches on/off immediately when the switch is oper ated. Internal shutter opens/closes automatically.
EV 31 with electrical internal shutter. For ventilation or air extraction. Speed controllable. On/off with light switch or separate switch (all to be supplied by customer).
The fan unit switches on/off
immediately when the switch is operated. The internal shutter opens/closes automatically.
EVH 31 with internal shutter and 1 metre long pull-cord for manual oper ation. For air extraction. The fan unit switches on/off by pulling the pull -cord. The int ernal shutter opens/closes automatically.
3. Technical Dat a
See r ating plate.
Dimensions and weight
I nternal housing: 410 x 410 x 130 mm
External grille: 410 x 410 x 23 mm
Window cut-out: 360 mm diameter
EV 31, EVR 31: 7.6 kg
EVH 31: 6.4 kg
Rated voltage and frequency
See r ating plate.
4. Environmental conditions and
operating lim i t s
Maximum permitted temper ature of the air medium: +40 °C
Suf ficient supply air intake must be ensured durin g operation with air- ventilated fi replaces. The maximum permitted pressure difference per living unit is 4 Pa.
5. Essential safety i nstructions
General safety instructions
Read t he safety instructions through carefully before commissioning.
Keep t he instructions.
The device must not be used as a toy.
I nstallation i s only permitted when carried
out by trained specialist s.
El ectrical connections and repairs only permitted when carried out by el ectricians.
Onl y connect the unit to a permanent electric al installat ion. Permitted cable cross sec tion:
0.75 mm² to 1.5 mm². Use suitable, flexible connecting cable i f the unit is installed in a sw ivel window. Mains isolation device required with contact openings of at least 3 mm at each pole.
The f an unit may only be operated using the voltage and frequency shown on the rating plate.
Do not make any modific ations to the fan unit.
Onl y operate the fan unit when it is completely installed. Never operate without an external grille.
Oper ation is only permi tted when the inter­nal housing is in place and locked shut.
Intended use
EV 31 and EVH 31: For air extraction at offices, business and commercial premises, restaurants, manufacturing and workplaces, doctors pr actices, etc.
EVR 31: For ventilation or air extraction of the above-mentions premi ses.
For vertical installation in windows or thin walls.
I n hinged double-gl azed windows, composite windows and glass brick walls, only with the suitable Maico acces sory ZD or ZG.
Predictable misuses
Maico is not liable for dama ges cau sed by use contrary t o the intended purpose. Under no
circumstances should the unit be used:
on sloping walls, pitched roofs or ceilings.
GB
Page 5
12
close to flammable mat erials, li quids or gasses.
i n explosive atmosp heres.
Safe and correct practices during operation
Danger of injury Do not insert any objects in the unit.
Danger from self-turning impeller Do not get too clos e to the unit to avoid hair, clo­thing or jewel lery being drawn i nto the unit.
The unit is not int ended to be used by people whose physical, s ensory or mental capabilities are not sufficient for them to understand and put into practice the safet y informati on provided in thes e instructions. This restr iction also applies to children. The unit may however be safely used by s uch persons if they are supervised by someone responsibl e for their safety or if they are instructed in a suitable way.
6. Installation preparati on
Installation in windows
WARNING
Danger of cuts caused by sharp glass edges and glass breakage. Damage t o the window pane from mater ial stress.
If necessary, extract the
window pane and putty it back in place without stress.
NOTICE
Functional impair ment and unit damage if inst alled on an uneven substrat e.
Make sure there is a level
seating in the area of the window pane rings [7] and [10].
CAUTION
Danger of short-ci rcuits with sloping install ation position through the build- up of condensation in side the housing.
Only install the unit vertically,
with the cable f eed from above.
Decide on the installation position.
Maintain sufficient distance (min. 50 mm) from the window fr ame or wall/ceiling. Allow enough spac e for a correct cable feed and the opening area of the window.
Get an expert t o make the window cut-out
– diameter 360 mm.
Lay the power cable.
Installation in walls and wooden panels
Make the same preparati ons for the
installation in walls and wooden panels as described under Installation in windows.
Dismantling internal housing with connecting flange, see Figure A,
bottom left.
Loosen both catc hes [13] with a
screwdriver.
Hold on to the internal housing, slightly
angle the connecting flange and disconnect it from both locking hooks [3.1].
Pull the connection terminal pl ug [12] off. Remove the testing cables from the
connection t erminal socket [9]. These are no longer required.
GB
Page 6
13
7. Installation
Installation in windows
NOTICE
Faulty operation and unit damage caused by a rubbing impeller [14] with incorrect installation.
Do not install the internal
housing twis ted or crimped.
The internal housing [1] shoul d only be installed indoors. Outdoor installation of the internal housing [1] is not permitted.
Press the external grille [8] and the
connecting flange against t he window pane from outside and inside respectively.
Line the external grille and connecting
flange up horizontally and bol t them together with t he M5 x 25 bolts supplied [2]. The ball [11] can be used to help if unlatched first.
CAUTION
Danger of injury through glass breakage if the bolts are over­tightened.
Tighten the bolts carefull y and
do not over-tighten them.
Make sure you have enough sealant, e. g.
silicone in the case of special, e.g. corrugated gl ass.
Notes
Make sure there ar e no leaks at the window pane rings [7] and [10].
I n the case of a window pane that is > 8 mm thick, replac e the supplied bolts [2] with other suit able ones, of your own choosing.
Installation in walls and wooden panels
Drill through the 4 housing domes [ 8.1] on
the external grille – diameter 5.5 mm.
Install the external grille and connecting
flange as described before.
Mark additional drill holes on the wall
through the hous ing domes [8.1] .
Loosen the mountin gs a little and turn the
external grille with the connecting flange in the wall breakthrough by approx. 45°.
Drill through the wall (4 holes).
Line up the external grille with the
connecting f lange again and bolt them together as des cribed before.
Additionally, the external grille is fixed to
the connecti ng flange through t he 4 drilled holes. Make sure that suitable bolts and nuts are available on site.
i
i
GB
Page 7
14
Electrical connection
DANGER
Danger to life from electric shock
Switch the mains fuse off.
CAUTION
Unit damage in the case of short-circuits
Cut off and insulat e any
unnecessary cable cores.
CAUTION
Danger of short-circuits through incorrect feeding of the power cable into the housing.
Feed the power cable
professi onally through the cable grommet and make sure there is tension relief. See printed cable run.
Locate both cable grommets [5] in t he
connecting f lange.
Feed the power cable through the ope n
cable grommet.
Connect the power c able to the connection
terminal s ocket [9] as shown in the wiring diagram on Page 25.
Internal housing installation see also Figure A, bottom right
CAUTION
Danger of short-circuits and unit damage with wrong polarity
Make sure the polarity is
correct, see l abels A and B.
NOTICE
Damage to the contact holder caused by tearing or pulling on the plug cable
Always hold the inter nal
housing near t he connecting flange to avoid pulling tension at plug connect ion.
Plug the connect ion terminal pl ug [12] on to
the connecti on terminal socket [9].
Push the internal housing parall el onto the
connecting flange as shown bott om right in Figure A.
The internal housing must clip into the upper locking h ooks [3.1]. Don’t trap the cables.
Close both catches [13] with a screwdr iver. Switch the mains fuse on. Carry out a function test.
i
GB
Page 8
15
8. Operation
EV 31
Switch the unit on using the switc h, e.g.
speed controller ST… The internal shutter opens automatically. The fan unit runs and extracts air from the room.
Switch the unit off with the switch.
The internal shutter closes. The fan unit s w itches off.
EVR 31
Switch the unit on using the switc h, e.g.
reversing switch STW… The internal shutter opens automatically. The fan unit runs and ventilates or extracts air from the room.
Switch the unit off with the switch.
The internal shutter closes. The fan unit s w itches off.
EVH 31
NOTICE
Unit damage by jerky pulling at the pull-cord
Don’t pull the pull-cord in a
jerky way.
Switch the unit on by pulling the pull-cord
angled towards the front. The internal shutter opens mechanically. The fan unit runs and extracts air from the room.
Switch the unit off by pulling the pul l-cord
angled towards the window or wall and then return it to its base pos ition. . The internal shutter clos es mechanically. The fan unit s w itches off.
9. Maintenance
The unit is maintenance-free.
With fans in swivel windows
Check the connection cable regularly for
signs of damage at the transfer point from the window sash to t he window frame.
If the cable is damaged, have it repl aced
by a trained electrician.
10. Cleaning
DANGER
Danger to life. Unit is powered up
Switch the mains fuse off. Do not remove the internal
housing for c leaning.
Do not flood the unit with
liquid.
Clean the unit with a damp cloth.
11. Dismantl i ng ventilati on unit
see also Figure A, bottom left
DANGER
Danger to life from electric shock
Switch the mains fuse off.
Open both catches [13]. Swing the internal housing up slightly and
remove it.
Disconnect t he electrics. Remove the connect ing flange and external
grille.
GB
Page 9
16
12. Fault rectification
Call on the services of a trained electrician any time there is a fault.
Repai rs should only be carried out by a trained electrician.
DANGER
Danger to life. Unit is powered up
Switch the mains fuse off.
Fault Countermeasure
Unit doesn’t run. Thermal overload protection of the motor switches unit off and back on again after cooling down.
Localise the c ause of the fault and rectify it.
Tab. 1: Fault rectificat ion
13. Spare parts
When order ing spare parts, always quote the print number
0185.0853.0007 from these instructions, the rating plate number “X” and the cor responding item number.
Item, Page 2
Figure A
Designation
1 Internal housing, complete
– EV 31, EVR 31 – EVH 31
8 External grille VM 13 Catch 15 VM motor gear
– EV 31, EVR 31
Tab. 2: Spare par ts
14. Disposal
Not in domestic waste.
The unit contains in part mat erial that can be recycled and in part substances that should not en d up as domestic was te.
Dispose of the unit once it has reached t he
end of its working life accor ding to the regulations valid where you are.
i
i
GB