2. Selection and function keys
Keys Name Function
O
OK Confirm and store
Function depends on current menu
Back
Cancel
Back one menu level or cancel
or
Up or down control
or
Right or left control
Enter Confirm and store
C
Delete Deletes character to left of cursor
i
Information Show current data
Switching between number and
letter input. Current mode is shown
at bottom right of screen.
3. Refrigerant identification unit
D Before connecting service hoses proceed as follows:
1. Verify that the oil system type matches between the actual
vehicle A/C system and current configuration of the ACS
unit (PAG or POE). If required change oil type in “Settings
>> A/C Service Parameter” (see operating instructions
chapter 4.4).
2. Perform refrigerant identification (see operating instructions
chapter 6.3).
D Use of a refrigerant identifier reduces the risk of contamina-
tion of ArcticPro 200yf. If the service hoses are connected to
the vehicle before refrigerant identification there is the risk for
contamination the refrigerant system of ArcticPro 200yf.
M The contamination in the ArcticPro 200yf can only be removed
by a service provider at additional cost.
D The type of oil (PAG or POE) is always to be checked prior to
A/C service and altered to suit the type of vehicle.
3.1 Refrigerant analysis
M
Before first operation with refrigerant identifier please read
chapter 3.4 in Original instructions of ArcticPro 200yf.
1. Switch on the ArcticPro 200yf.
2. Select vehicle A/C service.
3. Switch on the refrigerant identification unit.
4. Follow the menu prompting of ArcticPro 200yf.
M Getting message “ Sample not OK ”, check for contamina-
tion of the test hose, then repeat the procedure up to 2 times.
M Getting message “ Sample not OK ” for three times, a
refrigerant verification must be performed.
3.2 Refrigerant verification
M
Connect refrigerant identification unit to an external R1234yf
bottle with 100 % R1234yf.
1. Connect refrigerant identification unit to the power supply.
2. Switch on the refrigerant identification unit.
M Do not connect USB connecting cable with ArcticPro 200yf.
3. Follow the menu prompting of refrigerant identification unit.
M Contact customer service after not passed analysis for 3 times.