Magnum Venus Plastech VHPC-1200 User Manual

VHPC
-
Pump Manual
Rev. 05/2011
VHPC-1200 Metering Pump Manual
CORPORATE HEADQUARTERS and MANUFACTURING
11692 56th Court * Clearwater, FL 33760 * Tel 727-573-2955 * Fax 727-571-3636
TECHNOLOGY CENTER and MANUFACTURING
1862 Ives Ave. * Kent, WA 98032 * Tel 253-854-2660 * Fax 253-854-1666
MVP Plastech UK
Chilsworthy Beam, Gunnislake, Cornwall, PL18 9AT UK, * Tel: +44 (0) 1822 832621
Fax: +44 (0) 1822 833999
www.mvpind.com
Rev. 05/2012 Page | 2
TABLE OF CONTENTS:
VHPC-1200 Metering Pump Manual
SECTION:
Page
TERMS & CONDITIONS OF SALE 4
SAFETY & WARNING INFORMATION 6
INTRODUCTION 15
METERING PUMP DISASSEMBLY 17
METERING PUMP ASSEMBLY 18
PARTS DRAWINGS 20
REVISION INFORMATION 24
Rev. 05/2012 Page | 3
VHPC-1200 Metering Pump Manual
Terms & Conditions of Sale:
Customs duties, import and export licenses and certificates, if required, and all local taxes are excluded from this offer. If US state and local taxes are applicable and not included in equipment invoice, such amount may be invoiced later.
Delivery dates or shipping schedules are approximate and based upon the most recent information available at the time of order. Dates may be adjusted upon receipt of subsequent information or modification of order. Seller will ship prior to the delivery date if possible, but not without Buyer’s consent on Advanced Equipment sales.
All contract dates and timelines begin upon receipt at MVP of customer purchase order, signed Terms and Conditions of Sale (if applicable), and down payment per quotation (if applicable).
If shipments are delayed by the Buyer, or because the Buyer’s account is in arrears, payments shall become due on the date when the Seller is prepared to make shipment. Products held by the Seller for the Buyer shall be at the risk and expense of the Buyer.
Damages, defects or shortages must be communicated immediately to MVP. Discrepancy in pricing and/or quantities on invoices must be reported within 30 days of the invoice date. Claims made 30 days or more following the invoice date will not be honored.
Permission to return items must be requested and granted in advance. No credit will be given if items are returned prior to requesting and receiving permission. All returns are subject to a restocking fee. The standard 15% charges may be increased or decreased depending on the reason for the return. Special ordered items may not be returned.
Seller warrants that the mechanical operation of the goods as specified shall be free from faults in respect to materials and workmanship for a period of 12 months for parts from the date of invoice. For systems, 12 months from start-up or, if earlier, 18 months from the date of the Bills of Lading. The warranty does not cover general wear and tear or damage due to negligence or improper use. Seller’s liability under the warranty shall be limited solely to repair or replacement costs, and has no responsibility for reimbursing repair cost incurred by Buyer in connection with equipment without first giving written authorization for such charges. Seller makes no express warranties except those set forth in this agreement, and disclaims all other warranties, expressed or implied, including without limitation, implied warranties of non-infringement merchantability and fitness for a particular purpose. Seller accepts no liability for loss of production, loss of profits, or other direct or indirect damages. In any claim by the Buyer
Rev. 05/2012 Page | 4
VHPC-1200 Metering Pump Manual
against the Seller in respect of the goods, the liability of the Seller shall be limited to the value of the goods.
Many factors beyond Seller’s control contribute to the success of Buyer’s finished products, such as raw materials used to manufacture the product. Equipment is warranted to perform to specifications detailed in quotation, but Seller is not liable for quality or quantity of finished products produced by Buyer.
The country of origin is the United States of America. Sale, installation and all rights of the parties are governed by the laws of the state of Florida. Venue with regard to any litigation shall be in Pinellas County, Florida. The parties agree to waive all rights to trial by jury as to any and all disputes.
The goods remain the property of the Seller until full payment is received.
Sale of equipment is subject to application and issuance of proper US Government
export license and regulations, if applicable.
Installation of equipment is responsibility of Buyer and Seller, with cost responsibility and number of days provided as detailed in original customer Quotation. Seller will provide installation supervision personnel within 30 days of customer request. If installation is delayed by the Buyer more than six months from the date of shipment, or if customer facility or material/parts are not prepared for installation, seller will invoice full installation costs, up to $1,250 a day plus expenses, for each MVP installation technician on site. Seller has the option to waive this fee at its discretion.
Parties shall be excused for delays caused by embargoes, acts of civil or military authorities, Acts of God, or other circumstances beyond the reasonable control of the parties. Notification of such delays must be made in writing within ten days of occurrence.
Our agreement supersedes any previous agreement and applies in full.
Rev. 05/2012 Page | 5
VHPC-1200 Metering Pump Manual
SAFETY & WARNING INFORMATION
OPERATING YOUR POLYESTER SYSTEM SAFELY
1. Introduction
Any tool, if used improperly, can be dangerous. Safety is ultimately the responsibility of those using the tool. In like manner, safe operation of polyester processes is the responsibility of those who use such processes and those who operate the equipment. This manual o utlines procedures to be followed in conducting polyester operations safety. This system has been specifically designed for use of Polyester Resin, Gel-Coat, and Methyl Ethyl Ketone Peroxides (MEKP) applications. Other formulations or blends considered for use in this equipment is strictly prohibited without the expressed consent by Magnum Venus Plastech Inc. Magnum Venus Plastech cannot eliminate every danger nor foresee every circumstance that might cause an injury during equipment operation. Some risks, such as the high pressure liquid stream that exits the spray tip, are inherent to the nature of the machine operation and are necessary to the process in order to manufacture the end-product. For this reason, ALL personnel involved in polyester operations should read and understand the Safety Manual. It is very important for the safety of employees involved in the operation that equipment operators, maintenance and supervisory personnel understand the requirements for safe operation. Each user should examine his own operation, develop his own safety program and be assured that his equipment operators follow correct procedures. Magnum Venus Plastech hopes that this manual is helpful to the user and recommends that the precautions in this manual be included in any such program. Magnum Venus Plastech recommends this Safety Manual remain on your equipment at all times for your personnel safety. In addition to the manual, Magnum Venus Plastech recommends that the user consult the regulations established under the Occupational Safety & Health Act (OSHA), particularly the following sections:
1910.94 Pertaining to Ventilation.
1910.106 Pertaining to flammable liquids
1910.107 Pertaining to spray finishing operations, particularly Paragraph (m) Organic Peroxides and Dual Component Coatings.
Other standards and recognized authorities to consult are the National Fire Protection Association (NFPA) bulletins as follows:
NFPA No.33 Chapter 14, Organic Peroxides and Dual Component Materials
NFPA No.63 Dust Explosion Prevention
NFPA No.70 National Electrical Code
NFPA No.77 Static Electricity
NFPA No.91 Blower and Exhaust System
NFPA No.654 Plastics Industry Dust Hazards
Type of Fire Extinguishing equipment recommended: Fire Extinguisher – code ABC, rating number 4a60bc.
Rev. 05/2012 Page | 6
VHPC-1200 Metering Pump Manual
Extinguishing Media – Foam, Carbon Dioxide, Dry Chemical, Water Fog.
Copies of the above bulletins are available, at a nominal charge from:
National Fire Protection Association 470 Atlantic Avenue Boston, MA 02210
Research Report No.11 of the American Insurance Association deal with “Fire, Explosion and Health Hazards of Organic Peroxides”. It is published by:
American Insurance Association 85 John Street New York, NY 10038
Local codes and authorities also have standards to be followed in the operation of your spraying equipment. Your insurance carrier will be helpful in answering questions that arise in your development of safe procedures.
1.2 Personal Safety Equipment
Magnum Venus Plastech recommends the following Personal Safety Equipment for conducting safe operations of the Polyester Systems:
Magnum Venus Plastech recommends that the user consult the state and local regulations established for all Safety equipment listed.
2.0 Material Safety
2.1 Hazards Associated with Laminating Operations
The major hazards which should be guarded against in polyester laminating operations are those associated with:
1. The flammability and explosion dangers of the catalyst normally used – Methyl Ethyl Ketone Peroxide (MEKP).
2. The flammability dangers of clean-up solvents sometimes used (Magnum Venus Plastech recommends that clean-up solvents be non-flammable), and of resin diluents used, such as styrene.
3. The flammability dangers of catalyst diluents, if used. (Magnum Venus Plastech recommends that catalyst not be diluted.
4. The flammability dangers of the uncured liquid resins used.
5. The combustibility dangers of the cured laminate, accumulations of over spray, and laminate sandings.
6. The toxicity dangers of all the chemicals used in laminating operations with respect to ingestion, inhalation and skin and eye hazards.
Rev. 05/2012 Page | 7
VHPC-1200 Metering Pump Manual
2.2 Catalyst (Methyl Ethyl Ketone Peroxide)
MEKP is among the more hazardous materials found in commercial channels. The safe handling of the “unstable (reactive)” chemicals presents a definite challenge to the plastics industry. The highly reactive property which makes MEKP valuable to the plastics industry in producing the curing reaction of polyester resins also produces the hazards which require great care and caution in its storage, transportation, handling, processing and disposal. MEKP is a single chemical. Various polymeric forms may exist which are more or less hazardous with respect to each other. These differences may arise not only from different molecular structures (all are, nevertheless, called “MEKP”) and from possible trace impurities left from the manufacture of the chemicals, but may also arise by contamination of MEKP with other materials in its storage or use. Even a small amount of contamination with acetone, for instance, may produce an extremely shock-sensitive and explosive compound.
Contamination with promoters or materials containing promoters, such as laminate sandings, or w ith any readily oxidizing material, such as brass or iron, w ill cause exothermic “redox” reactions which can become explosive in nature. Heat applied to MEKP, or heat build-up from contamination reactions can cause it to reach what is called its Self-Accelerating Decomposition Temperature (SADT).
Researchers have reported measuring pressure rates-of-rise well in excess of 100,000 psi per second when certain MEKP’s reach their SADT. (For comparison, the highest pressure rate-of­rise listed in NFPA Bulletin NO.68, “Explosion Venting”, is 12,000 psi per second for an explosion of 12% acetylene and air. The maximum value listed for a hydrogen explosion is 10,000 psi per second. Some forms of MEKP, if allowed to reach their SADT, will burst even an open topped container. This suggests that it is not possible to design a relief valve to vent this order of magnitude of pressure rate-of-rise. The user should be aware that any closed container, be it a pressure vessel, surge chamber, or pressure accumulator, could explode under certain conditions. There is no engineering substitute for care by the user in handling organic peroxide catalysts. If, at any time, the pressure relieve valve on top of the catalyst tank should vent, the area should be evacuated at once and the fire department called. The venting could be the first indication of a heat, and therefore, pressure build-up that could eventually lead to an explosion. Moreover, if a catalyst tank is sufficiently full when the pressure relief valve vents, some catalyst may spray out, which could cause eye injury. For this reason, and many others, anyone whose job puts them in an area where this vented spray might go, should always wear full eye protection even when laminating operations are not taking place.
Safety in handling MEKP depends to a great extent on employee education, proper safety instructions and safe use of the chemicals and equipment. Workers should be thoroughly informed of the hazards that may result from improper handling of MEKP, especially in regards to contamination, heat, friction and impact. They should be thoroughly instructed regarding the proper action to be taken in the storage, use and disposal of MEKP and other hazardous materials used in the laminating operation. In addition, users should make every effort to:
A. Store MEKP in a cool, dry place in original containers away from direct sunlight and away from other chemicals.
B. Keep MEKP away from heat, sparks and open flames.
C. Prevent contamination of MEKP with other materials, including polyester over spray and sandings, polymerization accelerators and promoters, brass, aluminum and non-stainless steels.
Rev. 05/2012 Page | 8