Magnum Venus Plastech CPR-2000 User Manual

Page 1
Cipher Gun
CPR-2000
MAGNUM VENUS PRODUCTS
Operations Manual
Cipher Gun
Page 2
Cipher Gun
Operations Manual
Corporate Headquarters/Manufacturing 5148 113th Ave., Clearwater, FL 33760 USA Phone: (727) 573-2955 Fax: (727) 571-3636 Email: info@mvpind.com Web: www.magind.com
Sales/Service 320 North Main St., Goshen, IN 46528 USA Phone: (574) 534-1434 Fax: (574) 534-1502
©2002 Magnum Venus Products
Cipher Gun
MVP-Canada/Sales/Service 80 Beauvais, Delson, PQ J0L 1GO Canada Phone: (450) 638-4330 Fax: (450) 638-3741
Page 3
Table of Content s
Cipher Gun
Operations Manual
CHAPTER 1 - DISASSEMBLY OF CIPHER GUN (CPR-2000) Gun Handle Disassembly
Gun Block Disassembly Flush Valve Disassembly Catalyst Injector Disassembly
CHAPTER 2 - ASSEMBLY OF CIPHER GUN Flush Valve Assembly
Gun Head Assembly Gun Handle Assembly Catalyst Injector Assembly Gun Head to Handle Assembly
CHAPTER 3 - GUN ADJUSTMENT & START UP
CHAPTER 4 - TROUBLESHOOTING Catalyst Problems
Resin Problems Flush Problems General Problems
CHAPTER 5 - PARTS DRAWINGS
Cipher Gun
Page 4
Chapter
1
Cipher Gun
Disassembly
Always remove fluid pressures before working on the unit.
Be careful not to bend the catalyst and resin needles.
WARNING
WARNING
Initial Disassembly . . .
1. Remove Catalyst, Resin and Flush fluid pressure from system before disassembly.
2. Remove Catalyst, Resin and Flush lines from the Gun Block Assembly (CPR-2001-01).
3. Remove Screw (00145) from Trigger Stud (54630-1).
4. Remove Trigger Stud from Gun Handle (54350-3) and Trigger (54360-1).
5. Remove Trigger (54360-1) from gun assembly.
6. To remove the Gun Block Assembly (CPR-2001-01) from Gun Handle (54350-3) remove Cap Screw (F-CS-04C-12) located at the back center, just above the Gun Block Assembly (CPR-2001-01).
You now have two components, the Gun Block Assembly and Gun Handle Assembly.
Gun Handle Disassembly
1. Remove Spring Retainers (54000-1) and Springs (04039-1).
2. Remove Valve Body Assembly (54440-1) from Handle (54350-3).
3. Remove Spring (04070-1) and Poppet Assembly (MG-2031).
Cipher Gun
Page 5
Gun Block Disassembly
1. Pull Catalyst Needle and Resin Needle (CPR-2005-01) from their Housings
2. Remove Nozzle Cap (8704-4-1), Nozzle, and Turbulent Mixer
3. Remove the Mix Housing (5104-20-1) by removing the two Cap Screws (F-CS­1024-09).
4. Take the Catalyst Injector (5104-03-01) out of the Distribution Ring (5104-17-1) (see Catalyst Injector Disassembly and Assembly for reference)
5. Remove the Mix Housing Seal (5104-12-1) and Distribution Ring (5104-17-1) from Mix Housing (5104-20-1).
6. Unscrew Catalyst Needle Housing (CPR-2012-01) from Gun Head (CPR-2001-
01)
7. Unscrew Resin Needle Housing (CPR-2004-01) from Gun Head (CPR-2001-01)
8. Remove Flush Valve Assembly (5104-01-01)
9. Remove Catalyst Plug (53110-1)
10. Remove Resin Fitting (MAX-2022) and Catalyst Fitting (MAX-2019).
Flush Valve Disassembly
1. Remove and discard the Flush Valve Split Seal (5104-21-1) from the Flush Valve Body (5104-24-1)
2. Remove the Flush Elbow Assembly (5104-02-01) from the Flush Valve Neck (5104-22-1)
3. Remove the Flush Valve Neck (5104-22-1) and the Flush Valve Seal (5104-26-
1) from the Flush Valve Body (5104-24-1). Discard the Flush Valve Seal (5104­26-1)
4. Remove the Flush Seal Body (5104-23-1) from the Flush Valve Button (5104­25-1)
5. Remove the Compression Spring (9203-2-3) from the Flush Valve Body (5104­24-1)
6. Remove and discard the O-Ring (7301-3-007) from the Flush Seal Body (5104­23-1)
7. Remove and discard O-Ring (7301-13-008)* from the Flush Valve Button (5104­25-1)
Catalyst Injector Disassembly
(See drawing Injector Assembly (5104-03-01) for reference)
1. Remove Injector Seal (5104-13-1) from Injector Body (5104-15-1)
2. Unscrew Plunger Retainer (5104-14-1) from Injector Plunger (5104-16-1)
3. Remove Compression Spring (9203-2-2) from Injector Plunger (5104-16-1)
4. Remove Injector Plunger (5104-16-1) from Injector Body (5104-15-1)
NOTE
Discard all parts to be replaced by the repair kit. All remaining parts
should be thoroughly cleaned, inspected for damage, and replaced if
necessary.
Cipher Gun
Page 6
Chapter
2
Cipher Gun
Assembly
WARNING
Be careful not to bend the catalyst and resin needles.
Flush Valve Assembly (5104-01-01)
(See Drawing Flush Valve Assembly (5104-01-01) for reference.)
1. Install the O-Ring (7301-13-008)* onto the Flush Valve Button (5104-25-1)
2. Install the O-Ring (7301-3-007) onto the Flush Seal Body (5104-23-1)
3. Install the Compression Spring (9203-2-3) into the Flush Valve Body (5104-24-1)
4. Push the Flush Valve Button (5104-25-1) through the Compression Spring (9203­2-3) located in the Flush Valve Body (5104-24-1), and screw on and tighten the Flush Seal Body (5104-23-1)
5. Install the Flush Valve Seal (5104-26-1) onto the Flush Valve Body (5104-24-1) and thread through the Flush Valve Neck (5104-22-1)
6. Install the Flush Elbow Assembly (5104-02-01) onto the Flush Valve Neck (5104­22-1)
7. Install the Flush Valve Split Seal (5104-21-1) onto the Flush Valve Body (5104-24-
1)
NOTE
* O-Ring (7301-13-008) EPR use with Acetone only
DO NOT USE GREASE WITH EPR O-RING
Gun Head Assembly (CPR-2001-01)
1. Place New O-Ring (O-S-012) on Catalyst Fitting (MAX-2019) and Resin Fitting (MAX-2022). Install both fittings into gun, making sure they are on the correct sides of the gun block
2. Install new Seal (02441-1) onto Plug (53110-1) then thread Plug into Gun Block
Cipher Gun
Page 7
3. Install Flush Valve Assembly (5104-01-01) into resin side of Gun Block
4. Install Distribution Ring (5104-17-1), with larger holes to the back, into the Mix Housing (5104-20-1)
5. Install new Mix Housing Seal (5104-12-1) into Mix Housing (5104-20-1)
6. Insert Catalyst Injector Assembly (5104-03-01) into Distribution Ring (5104-17-1)
7. Attach Mix Housing (5104-20-1) to Gun Block (CPR-2001-1) using the two (2) Cap Screws (F-CS-1024-09).
8. Install new O-Ring (O-S-012) into Catalyst Needle Seat area of the Gun Block
9. Install new O-Ring (O-S-012) on Catalyst Needle Housing (CPR-2012-01) and thread into Gun Block
10. Install new O-Ring (O-S-012) into Resin Needle Seat area of the Gun Block
1 1. Install new O-Ring (O-S-012) on Resin Needle Housing (CPR-2004-01) and thread
into Gun Block, lightly grease threads.
12. Install new O-Ring (O-S-006) onto both of the Piston Needles (CPR-2005-01)
13. Insert one Piston Needle (CPR-2005-01) each into the Catalyst Needle Housing (CPR-2012-01) and Resin Needle Housing (CPR-2004-01)
Gun Handle Assembly (54350-3)
1. Apply lubricant to Springs (04039-1) and insert into Gun Handle (54350-3)
2. Thread Spring Retainers (54000-1) over S prings (04039-1) into Gun Handle (54350-
3)
3. Slide Spring (04070-1) onto the end of the Poppet Assembly (MG-2031)
4. Insert Poppet Assembly (MG-2031) into Valve Body (54440-1)
5. Slide O-ring (O-S-104A) over Poppet Assembly (MG-2031) and retain with Packing Retainer (54420-1)
6. Screw Assembled Valve Body (54440-1) into the Gun Handle (54350-3)
Catalyst Injector Assembly (5104-03-01) Assembly
(See drawing Injector Assembly (5104-03-01) for reference)
1. Slide Injector Plunger (5104-16-1) thru Injector Body (5104-15-1)
2. Slide Compression Spring (9203-2-2) over Injector Plunger (5104-16-1)
3. Screw Plunger Retainer (5104-14-1) onto Injector Plunger (5140-16-1)
4. Install new Injector Seal (5104-13-1) onto Injector Body (5104-15-1)
Assembly Gun Head (CPR-2001-01) and Gun Handle (54350-3)
1. Attach the Gun Block Assembly (CPR-2001-01) to the Gun Handle (54350-3) using Cap Screw (F-CS-04C-12).
2. Slide Trigger (54360-1) into place against the needles and line up the holes with the handle.
3. Push Trigger Stud (54630-1) thru both the Trigger (54360-1) and the Gun Handle (54350-3) and retain with Screw (00145).
Cipher Gun
Page 8
Chapter
3
Cipher Gun
Gun Adjustment & St art up
Gun Adjustment and Start Up
1. Make sure trigger and trigger bar are not worn, loose or damaged before adjusting gun or needle guides.
2. Adjust the Resin Needle Guide and Jam Nut so they will open just before the Catalyst Needle, never catalyst first. How much you open the resin needle before you open the catalyst needle will depend on the resin viscosity and may have to be changed as the resin temperature changes. See the Testing and Adjusting Manual (12016-2) for testing your gun.
3. Test the gun by putting 100psi of air to the catalyst and resin fittings and putting the gun in a tub of water.
Cipher Gun
Page 9
Chapter
4
Cipher Gun
T roubleshooting
Catalyst Problems
1. Catalyst leaking around Needle (inside Needle Housing CPR-2003-02)
· Replace O-Ring (O-S-006) on Needle
· Check for excessive pressure in catalyst system
2. Catalyst leaking around Needle Housing
· Replace O-Ring (O-S-012) on Needle Housing (CPR-2003-02)
3. Catalyst leaking from the Mix Housing / front of the gun
· Check Piston Needle (CPR-2005-01) for wear or damage
· Replace Catalyst Seat (CPR-2012-02) or Catalyst Housing/Seat (CPR-2012-01)
· Replace O-Ring (O-S-012) under the catalyst seat
· Damaged or Weak Return Spring (04039-1), replace as needed
· Check for excessive pressure in catalyst system
4. Catalyst leaking from around plug on the side of the gun head
· Replace plug Seal (02441-1)
5. No catalyst from the gun
· Make sure trigger is pulling catalyst needle back / open
· Check Catalyst Injector (5104-03-01) for proper operation (drawing 5104-03-01)
· Check gun block for blockages
· Check catalyst pump for proper operation (See catalyst pump manual)
6. Catalyst leaking between fitting and gun block
· Replace O-Ring (O-S-012)
Resin Problems
1. Resin leaking around Needle (inside Needle Housing CPR-2004-01)
· Replace O-Ring (O-S-006) on Needle
2. Resin leaking around Needle Housing
· Replace O-Ring (O-S-012) on Needle Housing (CPR-2004-01)
3. Resin leaking from the Mix Housing / front of the gun
· Check Piston Needle (CPR-2005-01 for wear or damage
· Replace Resin Needle Housing (CPR-2004-01)
· Replace O-Ring (O-S-012) under the resin Needle Housing
· Damaged or Weak Return Spring (04039-1), replace as needed
· Check for excessive pressure in resin system
Cipher Gun
Page 10
4. No Resin from the gun
· Make sure trigger is pulling resin needle back / open
· Check gun block for blockages
· Check resin pump for proper operation (See resin pump manual)
5. Resin leaking between fitting and gun block
· Replace O-Ring (O-S-012)
Flush Problems (reference drawing 5104-01-01)
1. Solvent leaking from around flush button (inside flush body)
· Replace O-Ring (7301-13-008)* on valve button
2. Solvent leaking from around flush neck (next to gun block)
· Replace Split Seal (5104-21-1)
3. Solvent leaking from between the flush neck and flush body
· Replace Flush Valve Seal (5104-26-1)
4. Solvent leaking around flush elbow fitting
· Tighten flush swivel Elbow Fitting (7701-6-1)
· Replace Nylon Seal (7304-3-1)
· Replace flush swivel Elbow Fitting (7701-6-1)
5. Solvent leaking from Mix Housing / front of the gun
· Check for debris in seal area or damage to flush body
· Replace O-Ring (7301-3-007) on flush seal body
· Check for excessive pressure is flush system, set to no more than 80psi
General Problems
1. Material leaking from around the mix chamber
· Replace Mix Housing Seal (O-S-016) or (5104-12-1)
· Replace Catalyst Injector Seal (5104-13-1)
2. Air leaking from around poppet needle
· Tighten Retainer (54420-1) (caution do not over tighten, this will make the poppet needle move slowly or not move at all.)
· Replace O-Ring (O-S-104A)
3. Air leaking from around poppet valve body
· Tighten Poppet Valve Body (54440-1) into Gun Handle (54350-3)
4. Air leaking from fitting on handle or to chopper
· Retainer (54420-1) may be too tight and holding valve open
· Check Poppet Assembly (MG-2031) for wear or damage
· Check Poppet Valve Body (54440-1) seat area for wear or damage
5. Material leaking from around nozzle or nozzle cap
· Tighten Nozzle Cap (8704-4-1) (caution do not over tighten or you may damage the Turbulent Mixer (5107-27-3)) Hand tighten only
· Check Turbulent Mixer (5107-27-3) for damage or wear
· Check front of Mix Housing (5104-20-1) for damage
6. Trigger Action stiff or hard
· Check Trigger (54360-1) for damage
· Check Trigger Stud (54630-1) and Screw (00145) for damage, remove and lubricate as needed.
· Check Needle Guides (53900-1) and Spring (04039-1) for damage, remove and lubricate as needed
· Check Spring Retainer (54000-1) for wear or damage
· Check Needles (CPR-2005-01) and Needle Housings for hardened or sticky material
Cipher Gun
Page 11
Chapter
5
Cipher Gun
Parts Drawings
Cipher Gun
Page 12
Cipher Gun
MAGNUM VENUS PRODUCTS
CIPHER GUN CPR-2000
08-09-02
Page 13
CIPHER GUN
CPR-2000 P ARTS LIST
ITEM PART # DESCRIPTION QTY
1 7701-6-18 Elbow 1 2 54350-3 Gun Handle 1 3 00145 Screw 1 4 54630-1 Stud 1 5 54360-1 Trigger 1 6 04039-1 Spring 2 7 54000-1 Retainer 2 8 53900-1 Needle Guide 2 9 53800-1 Jam Nut 2
10 CPR-2005-01 Piston Needle 2
*11 O-S-006 O-Ring 2
12 CPR-2004-01 Needle Housing (MAT.) 1
*13 O-S-012 O-Ring 6
14 CPR-2003-02 Needle Housing (CAT.) 1 16 CPR-2001-01 Gun Head 1 17 F-CS-04C-12 Cap Screw 1
*18 O-S-016 Seal 1
19 5104-03-01 Injector 1 20 5104-17-1 Distribution Ring 1 21 5104-20-1 Mix Housing 1
*22 5107-27-3 Turbulent Mixer 1
23 F-CS-1024-09 Cap Screw 2 24 VFIT-6025-HT Fit Nozzle 1 25 8704-4-1 Nozzle Cap 1 26 53110-1 Plug 1
*27 02441-1 Seal 1
28 04070-1 Spring 1 29 MG-2031 Poppet Assembly 1 30 54440-1 Valve Body 1
*31 O-S-104A O-Ring 1
32 54420-1 Retainer 1 33 02883-8 Pin 1 34 56190-1 Screw 1 35 04420-1 Spring 1 36 F-HN-1024 Nut 1 37 56100-1 Nut 1 38 MAX-2019 Catalyst Fitting 1 39 MAX-2022 Material Fitting 1 40 5104-01-01 Flush Valve 1 41 CPR-2012-02 Catalyst Seat 1
INCLUDED BUT NOT SHOWN
* CPR-2000-SK Seal Kit
Kit also includes 5104-13-1 Injector Seal for part 19 (5104-03-01)
OPTIONAL EQUIPMENT
VPG-1001 Static Mixer Housing VPG-1002 Diffuser/Gasket (Place between tip and housing) VPG-1003 Static Mixer 5104-07-01 Ball Valve Flush CPR-2012-01 Catalyst Housing/Seat Assembly
includes item 13 (O-S-012 (Qty. 2), Item 14 (CPR-2003-02) and item 41 (CPR-2012-02)
Cipher Gun
Page 14
MAGNUM VENUS PRODUCTS
CIPHER GUN CPR-2000-SK
Cipher Gun
Page 15
INJECTOR ASSY - GB1S1 (5104-03-01)
PARTS LIST
ITEM PART # DESCRIPTION QTY
1 5104-16-1 Injector Plunger 1 2 5104-15-1 Injector Body 1 3 5104-14-1 Plunger Retainer 1 4 5104-13-1 Injector Seal 1 5 9203-2-2 Compression Spring 1 6 D5104-03-1 Injector Assy - GB1S1 Dwg 1
MAGNUM VENUS PRODUCTS
SystemOne - Injector Assy - GB1S1 5104-03-01
D5104-03-01 Rev. - 11/24/99
Cipher Gun
Page 16
Flush Valve Assy (5104-03-01)
PARTS LIST
ITEM PART # DESCRIPTION QTY
1 5104-22-1 Flush Valve Neck 1 2 5104-23-1 Flush Seal Body 1 3 5104-26-1 Flush Valve Seal 1 4 5104-24-1 Flush Valve Body 1 5 5104-25-1 Flush Valve Button 1 6 5104-21-1 Flush Valve Split Seal 1 7 9203-2-3 Compression Spring 1 8 7301-13-008 O-Ring 1
*Do not grease this O-Ring*
9 7301-3-007 O-Ring 1
ITEM PART # DESCRIPTION QTY
10 7304-3-1 Nylon Seal 2 11 7701-6-1 Elbow Fitting 1 12 7701-6-3 Barb Fitting 1 13 7701-2-1 Hose Clamp 1
OPTIONAL P ARTS AND ASSEMBLIES
8B 7301-11-008 O-Ring 1
15 5104-02-01 Flush Elbow Assy 1
MAGNUM VENUS PRODUCTS
Flush Valve Assy 5104-01-01
REV. A = ITEM 8, 7301-13-008 WAS 7301-11-008, ADDED *DO NOT GREASE THIS O-RING* NOTE
Cipher Gun
D5104-01-01 Rev. A - 11/05/01
Page 17
Cipher Gun
Page 18
Cipher Gun
Page 19
Cipher Gun
Page 20
Corporate Headquarters/Manufacturing 5148 113th Ave., Clearwater, FL 33760 USA Phone: (727) 573-2955 Fax: (727) 571-3636 Email: info@mvpind.com Web: www.magind.com
Sales/Service 320 North Main St., Goshen, IN 46528 USA Phone: (574) 534-1434 Fax: (574) 534-1502
©2002 Magnum Venus Products
Cipher Gun
MVP-Canada/Sales/Service 80 Beauvais, Delson, PQ J0L 1GO Canada Phone: (450) 638-4330 Fax: (450) 638-3741