Magnum Venus Plastech CPR-2000 User Manual

Cipher Gun
CPR-2000
MAGNUM VENUS PRODUCTS
Operations Manual
Cipher Gun
Cipher Gun
Operations Manual
Corporate Headquarters/Manufacturing 5148 113th Ave., Clearwater, FL 33760 USA Phone: (727) 573-2955 Fax: (727) 571-3636 Email: info@mvpind.com Web: www.magind.com
Sales/Service 320 North Main St., Goshen, IN 46528 USA Phone: (574) 534-1434 Fax: (574) 534-1502
©2002 Magnum Venus Products
Cipher Gun
MVP-Canada/Sales/Service 80 Beauvais, Delson, PQ J0L 1GO Canada Phone: (450) 638-4330 Fax: (450) 638-3741
Table of Content s
Cipher Gun
Operations Manual
CHAPTER 1 - DISASSEMBLY OF CIPHER GUN (CPR-2000) Gun Handle Disassembly
Gun Block Disassembly Flush Valve Disassembly Catalyst Injector Disassembly
CHAPTER 2 - ASSEMBLY OF CIPHER GUN Flush Valve Assembly
Gun Head Assembly Gun Handle Assembly Catalyst Injector Assembly Gun Head to Handle Assembly
CHAPTER 3 - GUN ADJUSTMENT & START UP
CHAPTER 4 - TROUBLESHOOTING Catalyst Problems
Resin Problems Flush Problems General Problems
CHAPTER 5 - PARTS DRAWINGS
Cipher Gun
Chapter
1
Cipher Gun
Disassembly
Always remove fluid pressures before working on the unit.
Be careful not to bend the catalyst and resin needles.
WARNING
WARNING
Initial Disassembly . . .
1. Remove Catalyst, Resin and Flush fluid pressure from system before disassembly.
2. Remove Catalyst, Resin and Flush lines from the Gun Block Assembly (CPR-2001-01).
3. Remove Screw (00145) from Trigger Stud (54630-1).
4. Remove Trigger Stud from Gun Handle (54350-3) and Trigger (54360-1).
5. Remove Trigger (54360-1) from gun assembly.
6. To remove the Gun Block Assembly (CPR-2001-01) from Gun Handle (54350-3) remove Cap Screw (F-CS-04C-12) located at the back center, just above the Gun Block Assembly (CPR-2001-01).
You now have two components, the Gun Block Assembly and Gun Handle Assembly.
Gun Handle Disassembly
1. Remove Spring Retainers (54000-1) and Springs (04039-1).
2. Remove Valve Body Assembly (54440-1) from Handle (54350-3).
3. Remove Spring (04070-1) and Poppet Assembly (MG-2031).
Cipher Gun
Gun Block Disassembly
1. Pull Catalyst Needle and Resin Needle (CPR-2005-01) from their Housings
2. Remove Nozzle Cap (8704-4-1), Nozzle, and Turbulent Mixer
3. Remove the Mix Housing (5104-20-1) by removing the two Cap Screws (F-CS­1024-09).
4. Take the Catalyst Injector (5104-03-01) out of the Distribution Ring (5104-17-1) (see Catalyst Injector Disassembly and Assembly for reference)
5. Remove the Mix Housing Seal (5104-12-1) and Distribution Ring (5104-17-1) from Mix Housing (5104-20-1).
6. Unscrew Catalyst Needle Housing (CPR-2012-01) from Gun Head (CPR-2001-
01)
7. Unscrew Resin Needle Housing (CPR-2004-01) from Gun Head (CPR-2001-01)
8. Remove Flush Valve Assembly (5104-01-01)
9. Remove Catalyst Plug (53110-1)
10. Remove Resin Fitting (MAX-2022) and Catalyst Fitting (MAX-2019).
Flush Valve Disassembly
1. Remove and discard the Flush Valve Split Seal (5104-21-1) from the Flush Valve Body (5104-24-1)
2. Remove the Flush Elbow Assembly (5104-02-01) from the Flush Valve Neck (5104-22-1)
3. Remove the Flush Valve Neck (5104-22-1) and the Flush Valve Seal (5104-26-
1) from the Flush Valve Body (5104-24-1). Discard the Flush Valve Seal (5104­26-1)
4. Remove the Flush Seal Body (5104-23-1) from the Flush Valve Button (5104­25-1)
5. Remove the Compression Spring (9203-2-3) from the Flush Valve Body (5104­24-1)
6. Remove and discard the O-Ring (7301-3-007) from the Flush Seal Body (5104­23-1)
7. Remove and discard O-Ring (7301-13-008)* from the Flush Valve Button (5104­25-1)
Catalyst Injector Disassembly
(See drawing Injector Assembly (5104-03-01) for reference)
1. Remove Injector Seal (5104-13-1) from Injector Body (5104-15-1)
2. Unscrew Plunger Retainer (5104-14-1) from Injector Plunger (5104-16-1)
3. Remove Compression Spring (9203-2-2) from Injector Plunger (5104-16-1)
4. Remove Injector Plunger (5104-16-1) from Injector Body (5104-15-1)
NOTE
Discard all parts to be replaced by the repair kit. All remaining parts
should be thoroughly cleaned, inspected for damage, and replaced if
necessary.
Cipher Gun
Chapter
2
Cipher Gun
Assembly
WARNING
Be careful not to bend the catalyst and resin needles.
Flush Valve Assembly (5104-01-01)
(See Drawing Flush Valve Assembly (5104-01-01) for reference.)
1. Install the O-Ring (7301-13-008)* onto the Flush Valve Button (5104-25-1)
2. Install the O-Ring (7301-3-007) onto the Flush Seal Body (5104-23-1)
3. Install the Compression Spring (9203-2-3) into the Flush Valve Body (5104-24-1)
4. Push the Flush Valve Button (5104-25-1) through the Compression Spring (9203­2-3) located in the Flush Valve Body (5104-24-1), and screw on and tighten the Flush Seal Body (5104-23-1)
5. Install the Flush Valve Seal (5104-26-1) onto the Flush Valve Body (5104-24-1) and thread through the Flush Valve Neck (5104-22-1)
6. Install the Flush Elbow Assembly (5104-02-01) onto the Flush Valve Neck (5104­22-1)
7. Install the Flush Valve Split Seal (5104-21-1) onto the Flush Valve Body (5104-24-
1)
NOTE
* O-Ring (7301-13-008) EPR use with Acetone only
DO NOT USE GREASE WITH EPR O-RING
Gun Head Assembly (CPR-2001-01)
1. Place New O-Ring (O-S-012) on Catalyst Fitting (MAX-2019) and Resin Fitting (MAX-2022). Install both fittings into gun, making sure they are on the correct sides of the gun block
2. Install new Seal (02441-1) onto Plug (53110-1) then thread Plug into Gun Block
Cipher Gun
Loading...