Magnum Energy ME-RSA-M User Manual

ME-RSA-M Instruction Sheet
Magnum Energy, Inc.
2211 West Casino Rd.
Everett, WA USA 98204
www.magnumenergy.com
Introduction
The ME-RSA-M Remote Switch Adapter allows users to connect external switches and to remotely turn the inverter on and off from different locations. The ME-RSA-M requires a “momentary” type of switch and allows multiple switches in different locations to turn the inverter on and off.
The ME-RSA-M is simple to install and is designed to be used with inverters that provide a Stack port, such as the ME, MS, MS-AE, and RD Series inverters.
Installation
Refer to Figure 2 for the following steps to install the ME-RSA-M:
Crimp an appropriately sized wire to each butt-splice connector on the
1.
ME-RSA-M adapter, and ensure a tight connection.
Info: The red butt-splice connectors on the ME-RSA-M adapter ac­cept 22 to 18 AWG wire.
2. Connect the other end of the two wires to one (or more) external on/off switches. This external switch should be a “momentary” type of switch which returns to its normal position when released.
3. The ME-RSA-M adapter MUST be plugged into
the Stack port on the inverter
as shown in Figure 1.
Communication Ports
on the In verter/C h arger
ME-RSA-M
ME-RSA-M
must be
conn ected to
the Stack Po rt
RSA-M
Stack (re d )
Magnum N et (green)
Remote (b l ue)
BTS (yellow )
Figure 1, ME-RSA-M Connection to Inverter
Operation Steps
1. The inverter’s ON/OFF button (and on the ME-RC remote control, if connected) can be used in tandem with the switches connected to the ME-RSA-M.
2. The inverter will alternately turn on or off when either an external switch, a remote control, or the inverter’s ON/OFF button is alternately pressed.
Info: The charger will continue to function and is not affected by the ME-RSA-M adapter operation.
Part Number: 64-0023 Rev A 1
ME-RSA-M Instruction Sheet
Magnum Energy Inverter /Charger
(with Stack po rt)
ME-RSA-M
RSA-M
PWR
FAULT
Inverting
CHG
DC 12.6V 5A
INV
ON/OFF
CHARG ER
ON/OFF
ME-RC
Remote Control
External
Mo men t ary Co n tact
Switches
SELECT
F
A
U
C
S
S
L
T
S
E
TECHAG S M ETER SETUPSHO REINVERTER
Fuse
Inverter
Ba tter y Ba n k
O
ne push (on either switch, the inverter, or the remote) turns
the inverter ON; the next push (on either switch, the inverter,
or the remote) turns the inverter OFF.
Figure 2, ME-RSA-M Installation