Inverter Compatibility Sheet for the ME-ARC with Revision 3.0/3.01
Main Menu Menu Heading/Item
02A Output Volts ≥Level 4 [3]
02C Load Amps ≥Level 4 [4]
02D Input Amps ≥Level 4 [4]
02E Inv/Chg Amps ≥Level 4 [4]
02F Input AC (AC1) [F] MSH Models only
02G Input AC2 [F] MSH-RE Models
03B DC Volts-AGS ≥Level 1
03C Gen Run Time ≥Level 1
03E Since GenRun ≥Level 1
04A BMK Status ≥Level 1 [7]
04C DC Volts-BMK ≥Level 1 [7]
04D DC Amps-BMK ≥Level 1 [7]
04E AH In/Out ≥Level 1 [7]
04F Reset AH Out ≥Level 1 [7]
04G Total AH Out ≥Level 1 [7]
04H Minimum VDC ≥Level 1 [7]
04I Maximum VDC ≥Level 1 [7]
01E Temp Display ≥Level 1
02A Search Watts ≥Level 1
02B LBCO Setting ≥Level 2
02F Power Up Always [F] ≥Level 1
VDC Connect, Time Connect, AC-In Disabled
Disconnect Volts= 9.0-15.9* (12V)
OFF, 5-50 watts (1 watt increments)
Connect Time= 12:00A-12:00P
Disconnect Time= 12:00A-12:00P
Connect Volts= 9.0-15.9* (12V)
ME-ARC (REVISION 3.0/3.01) COMPATIBILITY MATRIX
Selections/Adjustments Range
Multi-Stage, Force Float, Restart Bulk
Inverter
Model/Level
Required.
The ME-ARC has many advanced settings, and is designed to work with the advanced features in your Magnum
inverter and/or other Magnum devices (i.e., ME-AGS-N or ME-BMK). The ME-ARC communicates with your inverter
to allow these advanced features to be set up or enabled. However, when the ME-ARC is released with a new
software revision, some of the features and functionality in this remote may not be available in an inverter or
networked accessory that has an earlier software level. In this case, when the advanced setting is requested from
the ME-ARC to your inverter (or any other Magnum device networked with the inverter), this setting is not
recognized and will not function. Use the steps below to help you determine which ME-ARC (Revision 3.0/3.01)
menus/features are compatible with your inverter.
1. Go to: http://magnumenergy.com/inverter-compatibility/ to determine your inverter’s compatibility level
(L1, L2, L3 or L4).
2. Use the table below to determine which ME-ARC ‘Features/Settings’ you want to use and what inverter
compatibility level is required (see ‘Inverter Model/Level Required’).
3. If your inverter compatibility level is the same or greater than the ‘Inverter Model/Level Required’, then
your inverter can support the device setting/feature you want.
4. If your inverter does not have the required compatibility level for a feature/setting you want, contact
Magnum Energy to determine if there is a software upgrade option for your inverter.
Magnum Energy, Inc. PN: 64-0030-030 Rev C Page 1 of 2

03F Max Charge Time ≥Level 4 [6]
03G Final Charge Stage ≥Level 4 [6]
04F Max Gen Run Time ≥Level 1
04I Gen Warm-up Time ≥Level 1
04J Gen Cooldown Time ≥Level 1
05A Charge Eff ≥Level 1 [7]
05B AmpHour Size ≥Level 1 [7]
Quiet Time Topoff= OFF, 30-120Min
OFF, ON= Start Quiet Time= 12:00A-12:00P
Stop Quiet Time= 12:00A-12:00P
Run Hour/Min/AM-PM= 12:00A-12:00P
Stop Amps Delay= 0-127 sec, 1-127 min
OFF, Start Gen SOC= 20-90%
Start= OFF, Ext Input, 65-95F (18-35C)
Stop Gen Volts= 9.1-16.0*, Float
Stop Volts Delay= 0-127 sec, 1-127 min
OFF, ON= Start Gen Time= 12:00A-12:00P
Stop Gen Time= 12:00A-12:00P
Start Gen AC Amps= OFF, 5-60A
Start Amps Delay= 0-127 sec, 1-127 min
Start Gen Volts= 9.0-15.9*
Start Volts Delay= 0-127 sec, 1-127 min
AC/AC1 Input= 60-100 VAC, UPS Mode
04A Gen Run VDC
03A AC Input Amps
04G Quiet Time
04B Gen Run Time
04C Gen Run Amps
04D Gen Run SOC
* 12-volt values shown; for 24-volts systems - multiply by 2 and for 48-volt systems - multiply by 4.
** These settings return to the factory default setting when power to the remote is removed.
[F] Features added to Rev 3.0/3.01. Also added: Recording AGS fault history, clearing inverter/AGS faults, and
displaying Load Support statuses.
ME-ARC (Rev 3.0/3.01) Compatibility Matrix Notes:
[1] Will not work with MM/MM-E/MM-AE/MMS/MMS-E models.
[2] AC Couple Mode activates when Battery Type = Custom with MS-PAE Series ≥Rev 4.1 or MS/MS-PE series ≥5.0.
[3] The AC output volts are accurate only when used with MS, MS-PE, MS-PAE or MSH Series inverters.
[4] The AC amps displays are not shown unless connected to MS-PE, MS-PAE or MSH Series inverters.
[5] Level 2 and 3 inverters can be used, but:
Level 2 inverters are limited from 1.0 hour to 4.5 hours,
Level 3 inverters <Rev 4.1 are limited from 1.0 hour to 6.5 hours,
Level 3 inverters ≥Rev. 4.1 (and MMS Rev 1.5) are limited from 1.5 hours to 6.5 hours;
Any setting outside these limited ranges is not recognized and reverts to the inverter's default absorption time
(2.0 hours).
[6] Requires ≥Level 4 to display.
[7] SOC features require the ME-BMK (Battery Monitor Kit) to be installed.
[8] To manually turn the generator "ON" with the remote, ME-AGS-N rev 5.0 or higher is required.
Magnum Energy, Inc. PN: 64-0030-030 Rev C Page 2 of 2