Magnum Energy ME-ARC User Manual

Page 1
Inverter Compatibility Sheet for the ME-ARC with Revision 3.0/3.01
Main Menu Menu Heading/Item
≥Level 1
≥Level 3 [1]
≥Level 3 [1][7]
≥Level 4
≥Level 1 [8]
01A DC Volts ≥Level 1
01B DC Amps ≥Level 1
01C Charge Time ≥Level 1
02A Output Volts ≥Level 4 [3]
02B Output Hz ≥Level 4
02C Load Amps ≥Level 4 [4]
02D Input Amps ≥Level 4 [4]
02E Inv/Chg Amps ≥Level 4 [4]
02F Input AC (AC1) [F] MSH Models only
02G Input AC2 [F] MSH-RE Models
03A AGS Status ≥Level 1
03B DC Volts-AGS ≥Level 1
03C Gen Run Time ≥Level 1
03D AGS Temp ≥Level 1
03E Since GenRun ≥Level 1
04A BMK Status ≥Level 1 [7]
04B SOC ≥Level 1 [7]
04C DC Volts-BMK ≥Level 1 [7]
04D DC Amps-BMK ≥Level 1 [7]
04E AH In/Out ≥Level 1 [7]
04F Reset AH Out ≥Level 1 [7]
04G Total AH Out ≥Level 1 [7]
04H Minimum VDC ≥Level 1 [7]
04I Maximum VDC ≥Level 1 [7]
01A Set Clock ≥Level 1
01B Contrast ≥Level 1
01C Backlight ≥Level 1
01D Power Save ≥Level 1
01E Temp Display ≥Level 1
02A Search Watts ≥Level 1
02B LBCO Setting ≥Level 2
02F Power Up Always [F] ≥Level 1
≥Level 3 [7]
≥Level 3 [1]
≥Level 3 [1]
VDC Connect, Time Connect, AC-In Disabled
Read Only
Read Only
Read Only
OFF**
Multi-Stage
Auto Connect
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
12:00A**
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
10.0 VDC
5 Watts
Fahrenheit
15 Minute
50%**
100%**
100%
50%
14.1
11.0
6:00P
6:00A
Always OFF
Disconnect Volts= 9.0-15.9* (12V)
Connect SOC= 20-98%
Fahrenheit, Celsius
OFF, 5-50 watts (1 watt increments)
9.0-12.2* VDC
Connect Time= 12:00A-12:00P
Disconnect Time= 12:00A-12:00P
Connect Volts= 9.0-15.9* (12V)
Read only display
Read only display
Time= 12:00A-12:00P
0-100%
0-100%
OFF, 1-60 Minutes
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
ME-ARC (REVISION 3.0/3.01) COMPATIBILITY MATRIX
SETUP
ON, OFF
Disconnect SOC= 21-100%
Read only display
Read only display
03 AGS Meters
04 BMK Meters
01 Remote Setup
FEATURES/SETTINGS
Auto Connect
Selections/Adjustments Range
Read only display
CTRL
01 DC Meters
01 ACIn Control
02 CHG Control [5]
02 AC Meters
[5]
User
setting
Read only display
Read only display
Read only display
03 Gen Control
Button
METER
Read only display
Read only display
SOC Connect [F]
Multi-Stage, Force Float, Restart Bulk
OFF, ON, AUTO
Read only display
Read only display
Default
setting.
02 Invert Setup
02C AC In - Time
02D AC In - VDC
Inverter
Model/Level
Required.
02E AC In - SOC [F]
The ME-ARC has many advanced settings, and is designed to work with the advanced features in your Magnum inverter and/or other Magnum devices (i.e., ME-AGS-N or ME-BMK). The ME-ARC communicates with your inverter to allow these advanced features to be set up or enabled. However, when the ME-ARC is released with a new software revision, some of the features and functionality in this remote may not be available in an inverter or networked accessory that has an earlier software level. In this case, when the advanced setting is requested from the ME-ARC to your inverter (or any other Magnum device networked with the inverter), this setting is not recognized and will not function. Use the steps below to help you determine which ME-ARC (Revision 3.0/3.01) menus/features are compatible with your inverter.
1. Go to: http://magnumenergy.com/inverter-compatibility/ to determine your inverter’s compatibility level
(L1, L2, L3 or L4).
2. Use the table below to determine which ME-ARC ‘Features/Settings’ you want to use and what inverter
compatibility level is required (see ‘Inverter Model/Level Required’).
3. If your inverter compatibility level is the same or greater than the ‘Inverter Model/Level Required’, then
your inverter can support the device setting/feature you want.
4. If your inverter does not have the required compatibility level for a feature/setting you want, contact
Magnum Energy to determine if there is a software upgrade option for your inverter.
Magnum Energy, Inc. PN: 64-0030-030 Rev C Page 1 of 2
Page 2
≥Level 1 [1]
MSH-RE Models
≥Level 1
Absorb (12.0-16.0) 14.6
Float (12.0-16.0) 13.4
EQ (12.0-16.0) 15.5
≥Level 2
≥Level 3
US Models
MSH-RE Models
Export Models
≥Level 4 [5]
≥Level 4 [6]
≥Level 4 [6][7]
03F Max Charge Time ≥Level 4 [6]
03G Final Charge Stage ≥Level 4 [6]
04F Max Gen Run Time ≥Level 1
04I Gen Warm-up Time ≥Level 1
04J Gen Cooldown Time ≥Level 1
05A Charge Eff ≥Level 1 [7]
05B AmpHour Size ≥Level 1 [7]
03C Max Charge Rate
100%
03 Charger
Setup
SETUP
≥Level 3 [2]
Auto
400 AH
≥Level 4
≥Level 1 [7]
60 Sec
OFF
OFF
OFF
12.0 Hrs
≥Level 1 ≥Level 1
≥Level 1
≥Level 1
≥Level 1
60 Sec
OFF
OFF
OFF
12.0 Hrs
Multi
11.5
120 Sec
14.4
120 Sec
20A
30A
80 VAC
75 VAC
Run Time= 0.0-25.5 hours
Flooded:
150 VAC
2.0 Hrs
Stop Gen AC Amps= 5-60A
0-127 sec, 1-127 min
0-127 sec, 1-127 min
Auto, 50-97%
200-2500 AH
Quiet Time Topoff= OFF, 30-120Min
OFF, 0.1-25.5 Hrs
OFF, ON= Start Quiet Time= 12:00A-12:00P
Stop Quiet Time= 12:00A-12:00P
Days= OFF, 1-255 days
Run Hour/Min/AM-PM= 12:00A-12:00P
Stop Amps Delay= 0-127 sec, 1-127 min
OFF, Start Gen SOC= 20-90%
Stop Gen SOC= 21-100%
Start= OFF, Ext Input, 65-95F (18-35C)
Time= 0.5-6.0 Hrs
Stop Gen Volts= 9.1-16.0*, Float
Stop Volts Delay= 0-127 sec, 1-127 min
OFF, ON= Start Gen Time= 12:00A-12:00P
Stop Gen Time= 12:00A-12:00P
Start Gen AC Amps= OFF, 5-60A
Time= 0.1-25.5 Hrs
10-100%
Start Amps Delay= 0-127 sec, 1-127 min
Amps= 0-150 ADC
SOC= 50-100%
0.0-25.5 hours
Multi, Float, Silent
Start Gen Volts= 9.0-15.9*
Start Volts Delay= 0-127 sec, 1-127 min
0-100%
AC/AC1 Input= 60-100 VAC, UPS Mode
AC2 Input= 60-100 VAC
110-190 VAC, UPS Mode
Custom
Gel, Flooded, AGM, AGM2
03B Battery Type
AC/AC1 Input= 5-60A
03E Absorb Done
04A Gen Run VDC 03A AC Input Amps
03D VAC Dropout
04 AGS Setup
05 BMK Setup
04E Gen Run Temp
04H Gen Exercise
04G Quiet Time 04B Gen Run Time
04C Gen Run Amps 04D Gen Run SOC
AC2 Input= 5-60A [F]
* 12-volt values shown; for 24-volts systems - multiply by 2 and for 48-volt systems - multiply by 4. ** These settings return to the factory default setting when power to the remote is removed. [F] Features added to Rev 3.0/3.01. Also added: Recording AGS fault history, clearing inverter/AGS faults, and displaying Load Support statuses.
ME-ARC (Rev 3.0/3.01) Compatibility Matrix Notes:
[1] Will not work with MM/MM-E/MM-AE/MMS/MMS-E models. [2] AC Couple Mode activates when Battery Type = Custom with MS-PAE Series ≥Rev 4.1 or MS/MS-PE series ≥5.0. [3] The AC output volts are accurate only when used with MS, MS-PE, MS-PAE or MSH Series inverters. [4] The AC amps displays are not shown unless connected to MS-PE, MS-PAE or MSH Series inverters. [5] Level 2 and 3 inverters can be used, but:
Level 2 inverters are limited from 1.0 hour to 4.5 hours, Level 3 inverters <Rev 4.1 are limited from 1.0 hour to 6.5 hours,
Level 3 inverters ≥Rev. 4.1 (and MMS Rev 1.5) are limited from 1.5 hours to 6.5 hours; Any setting outside these limited ranges is not recognized and reverts to the inverter's default absorption time (2.0 hours).
[6] Requires ≥Level 4 to display. [7] SOC features require the ME-BMK (Battery Monitor Kit) to be installed. [8] To manually turn the generator "ON" with the remote, ME-AGS-N rev 5.0 or higher is required.