Magnavox W-08CR, W-10CR, W-12CR Owner's Manual

Before using this product, please read the instructions carefully and keep for future reference.
MODEL: W-08CR W-10CR W-12CR
For any service needs, call 1-855-368-8606
OWNER'S MANUAL
CONTENTS
1
1. SAFETY PRECAUTIONS ...................................................................2
2. IMPORTANT SAFETY INSTRUCTIONS ............................................4
7. NORMAL OPERATING SOUNDS ....................................................17
Inside you will find many helpful tips on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the Troubleshooting Tips section.
Read This Manual
!
CAUTION
This appliance is not intended for use by children or persons with reduced physical,
sensory or mental capabilities, unless they are supervised by a responsible adult or
considered capable enough to operate the appliance safely.
Children should be supervised to ensure that they do not play with the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer
, its service
agent or similarly qualified persons in order to avoid a hazard.
The appliance should be installed in accordance with national wiring regulations.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
The appliance with electric heater should not be operated near any combustible materials.
Contact
the authorised service technician for any repairs, maintenance, or have problems
5........................................................ SERUTAEF RENOITIDNOC RIA
.
4. INSTALLATION INSTRUCTIONS .....................................................10
5. CLEANING AND MAINTENANCE ....................................................14
6. TROUBLESHOOTING TIPS .............................................................15
3
NOTE
:
All the illustrations in this manual are for explanation purposes only. Your air conditioner may appear to be slightly different.
installing the unit.
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation may cause harm or damage. The seriousness is classified by the warning symbols below.
Safety Precautions
This symbol indicates the possibility of death or serious injury.
Definition of symbols used in this manual are as shown below.
!
!
WARNING
Always do this.
Never do this.
!
CAUTION
This symbol indicates the possibility of injury or damage to property.
Plug in power plug properly.
Do not modify power cord length or share the outlet with other appliances.
Always ensure effective grounding.
Unplug the unit if strange sounds, smell, or smoke comes from it.
Keep firearms away.
Ventilate room before operating air
conditioner if there is a gas leakage from another appliance.
Otherwise, this may cause electric shock or fire due to excess heat generation.
This may cause electric shock or fire due to heat generation.
Incorrect grounding may cause electric shock.
This may cause fire and electric shock.
This may cause fire.
This may cause explosion, fire and, burns.
This may cause electric shock or
fire
due to heat generation.
This may cause electric shock.
This may cause failure of machine or electric shock.
This may cause fire and electric shock.
This may cause fire and electric shock.
This may cause electric shock or fire. If the power cord is damaged, it must be replaced by the manufac­ turer or an authorised service centre or a similarly qualified per­ son in order to avoid a hazard.
This could be harmful to your health.
Incorrect installation may cause fire and electric shock.
This may cause electric shock.
This may cause an explosion or fire.
This may cause failure and electric shock.
Do not operate or stop the unit by inserting or pulling out the power plug.
Do not operate with wet hands or in damp environment.
Do not allow water to run into electric parts.
Do not use the socket if it is loose or damaged.
Do not use the power cord close to heating appliances.
Do not damage or use an unspecified power cord.
Do not point airflow at room occupants directly.
Always install circuit breaker and a dedicated power circuit.
Do not open the unit during operation.
Do not use the power cord near flammable
g
as or combustibles, such
as
g
asoline, benzene, thinner, etc.
Do not disassemble or modify unit.
!
!
!
!
!
WARNING
!
2
!
!!
!
CAUTION
When the air filter is removed do not touch
the exposed metal parts.
y cause an injury.
Do not clean unit when power is on as it may cause fire and electric shock, cause an injury.
Operation with windows opened may cause water
When the unit is cleaned,
switch off, and turn off
the circuit breaker.
Stop operation and close the window in storm or hurricane.
Use caution when unpacking and installing. Sharp edges could cause injury.
Do not clean the air conditioner with water.
Water may enter the unit and degrade the insulation and
This could injure the pet or plant.
ay cause electric shock
and damage.
Do not put a pet or house plant where it will be exposed to direct air flow.
Hold the plug by the head of the power plug when taking it out.
Ventilate the room well when
a stove is being used in the
An oxygen shortage may occur.
Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects.
It may cause deterioration of qua
lity
, etc.
ay cause failure of product
or fire.
Do not use for special purposes.
Turn off the main power switch when not using the unit for a long time.
If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified service technician.
3
!!
!!
!!
!!
!!
!!
!!
appliance or accident.
Appearance may be deteriorated due to change of product color or weaken
Do not place obstacles around air-inlets or inside of air-outlet.
Do not use strong deter­gent such as wax or thinner, only use a soft cloth.
If bracket is damaged, there is danger of damage due to falling unit.
electric shock.
Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure.
Do not place heavy object on the power cord and ensure that the cord is not compressed.
Operation without filters may cause failure.
d
Always insert the filters securely. Clean filter once every two weeks.
Do not drink water drained from air conditioner.
!!
!!
This ma
cause electric shock.
or
damage to indoor property
This m
This m
This may cause failure of
the surface of the unit.
This may cause fire or
The water may contain contaminants and coul make you sick.
same room.
IMPORTANT SAFETY INSTRUCTIONS
Be sure the s adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille. Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards. Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation. Do not run air conditioner without side protective cover in place. This could result in mechanical damage within the air conditioner.
Do not use an extension cord or an adapter plug with unit.
WARNING
For your sa fety
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
fire hazard or electric shock, do not use an extension cord or an
adaptor plug. Do not remove any prong from the power cord.
WARNING
Electr ical Inform ation
NOTE For some models, the power
cord ir conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section Operation of Current Detection Device for details. In the event that the power cord is damaged, it cannot be repaired, it must be replaced with a cord from the Product Manufacturer.
,
,
Do no t, unde r any circumsta nces , cut, remove, o r bypass the g roundin g p rong.
Power cor d with 3- pr ong grounding plug and curre nt detection devi ce
Operation of Current Detection Device
(Applic able o nly to certain units with c urrent detecti on dev ice)
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a click as the RESET button pops out.
3. Press the RESET button, again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this it also indicated by
a ligh
t on the plug head.)
NOTES:
Do n
ot use this device to turn the unit on or off.
A
lways make sure the RESET BUTTON IS PUSHED IN for correct operation.
If pow
er cord is damaged, it cannot be repaired. It MUST be replaced by one obtained from the
product manufacturer.
4
Note : Perf ormance may be reduced outsi de of t hese opera ting temprerature ranges.
NOTE:This air conditioner is designed to be operated under the following conditions:
Cooling operation
Outdoor temp:
O O O O
18-43 C/64-109 F (18-52 C/64-125 F for special tropical models)
Indoor temp:
O
O
17-32 C/62-90 F
Heating operation
Outdoor temp:
O
O
-5-24 C/23-76 F
Indoor temp:
O
O
0-27 C/32-80 F
for this a
To avoid
power requirement i
The power cord contains a current detection function that senses damage to the power cord. To test your power cord, do the following:
The power cord must be replaced if it fails reset when either the TEST button is pushed, or it cannot
AIR CONDITIONER FEATURES
Before you begin, familiarize yourself with the control panel on the unit and the remote control as shown below and refer to the symbols for the functions you desire. The unit
can be controlled by either the unit controls or with the remote control.
ELECTRONIC CONTROL OPERATING INSTRUCTIONS
ADJUSTS TEMPERATURE OR TIME
ADJUSTS TEMPERATURE OR TIME
DISPLAYS TEMPERATURE OR TIME OR ERROR CODES
ACTIVATES TIMER
CHECK FILTER RESET BUTTON
SETS MODE
ENERGY SAVER MODE
SLEEP MODE
CLEAN AIR MODE (only on some models)
SET FAN SPEED
TURNS UNIT ON OR OFF
UNIT CONTROL
Temp Temp
Timer
Timer
On
Off
Sleep
Check Filter
Timer
Auto
Cool
Dry
Fan
Low
Auto
Med
High
Clean Air
Fan
Mode
Follow
Me Energy Saver
On/Off
5
FOLLOW ME INDICATOR (only on some models)
TO TURN UNIT ON:
NOTE: The following instructions represent the control panel on the unit,
Press the ON/OFF button.
Auto
Cool
Dry
Fan
Low
Auto
Med
High
Clean Air
Fan
Mode
Follow Me
Energy Saver
On/Off
DO THIS:
the same instructions can be used for the remote control.
NOTE: (ON/OFF button)
The unit will initiate automatically the Energy Saver function under COOL, DRY, AUTO (only Auto-Cooling and Auto-Fan) modes.
Loading...