Magnasphere MSS-K24S-W, MSS-K24S-G, MSS-K24S-B, MSS-K24-W, MSS-K24-G Specsheet

...
MSS Standard Series Product Sheet
Security Contacts have been made with a decades-old technology called the Reed switch. Reed switches have three inherent weaknesses when used in security contacts. They are (1) Easily defeated with magnets, (2) Prone to permanent contact weld failure (from lightning and power surges), and (3) fragile (made mostly of glass, they are subject to damage even when packaged as security contacts).
The MAGNASPHERE line of security sensors provides a solution to all of these issues. Utilizing the the patented, revolutionary MAGNASPHERE products virtually unbreakable, and highly resistant to permanent contact welding and outsider magnet defeat, allowing MAGNASPHERE to offer a lifetime replacement warranty.
®
BMS switch renders the MSS
Concealed/Recessed
Surface Mount
MSS contacts are available in both the traditional Closed Loop (contact closed when magnet is present) as well as the more Secure Open Loop (contact open when magnet is present) electrical configuration. This is the same configuration required for other life safety devices such as smoke and fire alarms, and has long been the recommend configuration by most knowledgeable security professionals.
Overhead Door
FEATURES
Made with MAGNASPHERE® BMS switch technology
Won't break
Resistant to contact welding
Resistant to outside defeat
Security industry's BEST warranty
Universal mounting
Cost competitive
Increases RMR
PATENTED DESIGN
#5977873, #RE39731, #6506987, #6303845, #6603378, and Patents Pending
Wireless
MAGNASPHERE CORP.
tel. 262.347.0711
|
23777 Stone Ridge Dr., Suite 160, Waukesha, WI 53188
|
fax 262.347.0710
|
www.MAGNASPHERE.com
®
Reed vs.
®
MAGNASPHERE
Security contacts are made with a decades-old technology called the Reed switch.
Reed switches have three inherent weaknesses when used in security contacts: (1) (2)
Prone to permanent contact weld failure
they are subject to damage even when packaged as security contacts).
(from lightning and power surges), and (3)
Easily defeated with magnets,
fragile
(made mostly of glass,
SECURE: NO ALARM
CLOSED
Door Frame
Door
Magnet
Reed contacts operate on magnetic fields. Most contacts are Closed in the secure position (Closed Loop) when the door is closed and the magnet is near the switch.
Reed switch contacts are globally magnetic: they will respond to the strongest magnetic field anywhere around the contact –– not solely to the door magnet. When compromised, reed contacts will still send secure signals.
FAILED: NO ALARM
CLOSED
Door Frame
Door Opened
Introducing a defeat magnet OUTSIDE the door will keep the reed contacts closed, allowing
Magnet
Defeat
an intruder to enter without alerting the security system.
FAIL SECURE.
They
NO ALARM
CLOSED
Door Frame
Door
Door
Magnet
Magnet
When closed reed contacts are exposed to power surges such as lightning strikes, they are prone to permanent contact welding.
© MAGNASPHERE CORP.
FAILED: NO ALARM
WELDED CLOSED
Door Frame
Door Opened
Reed contacts operate by magnetic induction, so they are not attracted to the door magnet.
Once contacts have welded closed, they remain in that state though the door is open. They
FAIL SECURE.
www.MAGNASPHERE.com
®
Reed vs.
®
MAGNASPHERE
The patented, award-winning MAGNASPHERE switch technology was designed as a security device which over comes the deficiencies of reed contacts.
switch is (1) and power surges, and (3) Robust, all metal welded construction is
Resistant to magnetic defeat and tamper,
(2)
Resistant to permanent contact welding
virtually unbreakable.
The MAGNASPHERE
from lightning
SECURE: NO ALARM
OPEN
CLOSED
ALARM
The Door is Open
A defeat magnet introduced OUTSIDE the door will have no effect on the ball
Magnet
Defeat
contact. When the door is opened, the contact will close, and the
WILL ALARM.
SYSTEM
The Door is Closed
MAGNASPHERE security sensors' magnet ball contact is open in the secure position (Open Loop) when the door is closed and the door magnet is near the switch.
NO ALARM
MAGNASPHERE’s contact is a spherical magnet and operates in a defined activation zone directed toward the door magnet.
ALARM
OPEN
The Door is Closed
MAGNASPHERE Security Sensors are Open Loop and highly resistant to contact welding from power surges and lightning strikes.
© MAGNASPHERE CORP.
CLOSED
The Door is Open
Because the magnet ball contact will not weld, when the door is opened the contact will close and the
WILL ALARM.
www.MAGNASPHERE.com
SYSTEM
Loading...