MAGNADYNE 6909P User's Manual

Page 1
OWNER’S
MANUAL
Model: 6909P
Page 2
Take a moment to become familiar with the operation of the primary features provided by your new security system as you may need to use them at some point in time. To test the primary features, repeat the following procedures exactly as they
are listed:
A patented removable switch is used to override the security system in the event that the transmitters are lost or fail to operate and to put the security system in non-operational mode (valet) for vehicle servicing etc.
Override Operation: (Security system is Armed)
1. Enter the vehicle, the security systems will begin sounding at this point, and place the override switch into the switch housing. Make sure that the switch button is in the OUT position.
2. Place the ignition key into the ignition switch and turn the ignition switch to the ON position.
3. Within 5 seconds of turning the ignition key ON, press the valet switch button IN until it locks.
4. The horn/siren will stop sounding.
5. The LED indicator will be solid red.
The security system is overridden and is now in the valet mode!
2
The information enclosed will provide a ready reference of the operation and maintenance of your new Silencer
®
security system. Follow the testing procedures as stated in this manual to test and operate features and functions on the Silencer
®
model 6909P security system.
Basic Operation
This section details the simple day to day operations of your Silencer®security system. The enclosed procedures should be performed every six months to insure that all functions are operating
properly. To perform a basic operations test, repeat the following procedures:
1. Exit the vehicle and close all protected entrances.
2. Press the LOCK button of your keyless entry transmitter. Your Silencer
®
security system will respond in the
following manner:
A. The horn/siren will beep one time. B. The LED status indicator will begin flashing. C. The parking lights will flash one time.
3. Press the UNLOCK button on your keyless entry transmitter. Your Silencer
®
security system will respond in
the following manner:
A. The horn/siren will beep twice. B. The LED will be off. (Only when the unit has not been programmed to automatically arm) C. The parking lights will flash two times.
4. Re-arm your Silencer
®
security system and wait 5 seconds.
5. Open one of the protected entrances of the vehicle. Your Silencer
®
security system will respond in the
following manner:
A. The horn/siren will begin to sound. B. The parking lights will begin to flash. C. The LED flash sequence will change to indicate that the security system had been triggered.
6. Press the UNLOCK button on your keyless entry transmitter once again. A. The horn/siren will stop sounding. B. The parking lights will stop flashing. C. The LED will remain flashing to indicate that the security system had been triggered. (Tamper indication)
7. Repeat steps 1 thru 6 for all other protected entrances and additional sensor devices.
Notations on Basic Testing and Operating Procedures.
1. When you disarm the security system while the horn/siren is sounding the normal disarm beeps are eliminated.
2. If the chirp status indication function is programmed off, you will not get any arm or disarm beeps.
3. After the security system has been triggered, the LED will remain flashing even though the security system
has been disarmed. This is a tamper indicator. Turning on the ignition key will reset the tamper indicator.
Primary Feature Operations
Note: The removable valet switch can only be inserted into the valet switch
housing one way. Do not force the switch or bend the switch terminals.
Page 3
3
Valet Operation: (The security system is already disarmed)
1. Place the valet switch into the switch holder making sure that the switch button is in the OFF position. (Switch button is out)
2. Turn the ignition key to the ON position.
3. Within 5 seconds of turning the ignition key ON, push IN the valet switch.
4. The LED will be on solid indicating that the security system is in the valet mode.
Note 1: If the valet switch is already in the ON position when you turn ON the ignition key, the valet function will be bypassed. Turn OFF the ignition key, set the switch to the OFF position and try again. Note 2: If you fail to push IN the valet switch within 5 seconds of turning ON the ignition key, the valet function will be locked out. Turn OFF the ignition key, set the switch to the OFF position and try again.
Starter Disable:
Your Silencer®security system has a built-in starter interrupt relay that will break the connection between your ignition key and the starter on your vehicle. To test this feature, repeat the following procedure:
1. Enter the vehicle and close all entrances.
2. Press the LOCK button on your keyless entry transmitter to arm the security system.
3. Place the ignition key into the ignition switch and try to start the vehicle. The starter will not crank the engine over.
4. Turn off the ignition key and press the UNLOCK button on your keyless entry transmitter to disarm the security system.
5.
Attempt to start the engine again. The starter will now engage and the engine will crank over and run.
Remote Panic:
The 6909P provides a remote panic function which allows the user to trigger the alarm by remote in the case of an emergency.
1. Ignition key must be off.
2. Press the LOCK button 4 times.
3. The siren will begin to sound and the parking lights will begin to flash.
4. Press the UNLOCK button. The siren will stop sounding and the parking lights will stop flashing.
Note: If the panic function is not turned off by the transmitter, the siren will continue to sound for 60 seconds and then turn off by itself.
Optional Features
Programmable Key Disarming:
If you have chosen to purchase the programmable key disarm option, your dealer should have provided you with 2 programmable keys to be used with your system. These keys are used as a secondary method to disarm your security system in the event you lose your factory keyless transmitter or you lend your vehicle to another family member and do not want to surrender your factory keyless transmitter to them.
Note: At the time when the programmable keys are programmed to operate your security system, the automatic arming function is turned on and the door trigger input circuit will have a 10 second delay. Repeat the following procedure to disarm your security system using the programmable key:
A. Unlock the driver’s door using the door key. (The LED indicator remains flashing.) B. Insert the programmable key into the key receptacle. (The LED will stop flashing and the horn/siren will
chirps two times indicating a disarmed condition.)
C. Remove programmable key. (The LED will begin flashing fast indicating that a re-arming timer is counting
and the security system will re-arm in 60 seconds.)
D. Insert the ignition key and turn it to the ON position. (The LED will stop flashing and be off) Drive the
vehicle as normal.
E. Every time the ignition key is turned off, the automatic arming circuit will operate as described in the “Last
Door Automatic Arming” section of this manual.
Warning! Do not turn on the ignition key before inserting the programmable key into the receptacle. The horn/siren will begin to sound!
Page 4
3 Year Warranty
Your new Silencer®Security Systems is warranted to be free of defects for 3 years. Silencer®or its authorized agents will within 3 years from the date of sale to you, repair or replace said product or any part thereof, at the option of the Silencer
®
or its authorized agents, if said product or part is found defective in materials or workmanship, when properly connected and operating on the correct power requirements designated for the specific product. This warranty and Silencer
®
or its authorized agents obligations hereunder do not apply where the product was; damaged while in the possession of the consumer, subjected to unreasonable or unintended use, not reasonably maintained, or serviced by anyone other than Silencer
®
or its authorized agents, or where the warning seal on the product is broken or the power and/ or plugs are detached from the unit. This warranty does not cover the cabinet appearance items or accessories used in connection with this product, or any damage to the products resulting from improper installation, alteration, accident, misuse, abuse or acts of nature. Silencer
®
OR ITS AUTHORIZED AGENTS SHALL NOT BE LIABLE TO ANYONE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES OR CLAIMS EXCEPT THOSE ACCORDED BY LAW. NO EXPRESSED WARRANTY OR IMPLIED WARRANTY IS GIVEN EXCEPT THOSE SET FORTH HEREIN. NO IMPLIED WARRANTY SHALL EXTEND BEYOND 3 YEARS FROM THE DATE OF SALE. Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. Defective merchandise should be returned to the original point of purchase or secondly, to 1111 W. Victoria Street, Compton CA 90220. Return Authorization must be obtained before sending, or merchandise may be refused. All claims concerning your Silencer
®
Security System should be referred to your selling dealer.
If you are away from the vicinity of the selling dealer please call (800) 340-3200.
6909PUM
C
hirp Delete:
The 6909P control module can be programmed by the dealer so there will be no arm/disarm status chirps. The four chirp tamper disarm warning indicator will always be on for you safety.
Pathway Illumination:
If the pathway illumination function has been programmed on by your dealer your vehicles parking lights will illuminate at the time the security system is disarmed by the remote transmitter. The parking lights will remain on for 30 seconds after the security system is disarmed. Turing on the ignition key will turn off the parking lights before 30 seconds.
Last Door Automatic Arming:
If your Silencer
®
security system was programmed to automatically arm without using the transmitter, repeat
the following procedures to test and operate this feature:
1. Enter the vehicle and close all the entrances.
2. Set the ignition key switch to the on position and wait for 5 seconds.
3. Set the ignition key switch to the off position and exit the vehicle. Upon closing the door, you will hear a
beep from the horn/siren. The beep is an indicator that the automatic arming timer has started counting. You will also notice that the LED indicator is flashing fast. This is also an indicator that the automatic arming timer is counting down.
4. Within 30 seconds, the horn/siren will beep once again. This is an indication that the security system is
now in the armed mode. The LED will begin flashing at a normal rate. Note: Once the ignition key switch is turned off, the automatic arming timer will start counting after the last protected entrance is closed. Re-opening any protected entrance within the 30 second time will stop the counter and reset it. Closing the entrance will start the counter once again but you will not get a beep when closing the door for the second time.
Ignition Key Controlled Door Locking/Unlocking:
If the ignition key lock/unlock function has been programmed on by your dealer the doors will automatically become locked 3 seconds after the ignition key is set to the on position or unlocked after ignition key is turned off.
1. Enter the vehicle and close all protected entrances.
2. Turn the ignition key to the on position.
3. Within 3 seconds the door locks will become locked.
4. Turn off the ignition key. The door locks will become unlocked.
Notations About Ignition Controlled Locking.
A. If a protected door is open, the ignition door locking function is disabled. B. If the door locks are manually locked, the alarm system will still unlock them when the ignition key is
turned off.