This specification applies to the Pb Free high current type SMD inductors for
MSI-110810-SERIES
PRODUCT INDENTIFICATION
(1) SHAPES AND DIMENSIONS
A: 10.7 Max. mm
B: 7.5 Max. mm
C: 9.5 Max. mm
D: 2.8±0.2 mm
E: 2.8±0.3 mm
(2) ELECTRICAL SPECIFICATIONS
SEE TABLE 1
TEST INSTRUMENTS
L : HP 4284A PRECISION LCR METER (or equivalent)
RDC : CHROMA MODEL 16502 MILLIOHMMETER (or equivalent)
(3)-1 Operate temperature range ...... -40℃~+125℃
(Including self temp. rise)
(3)-2 Storage temperature range ...... -40℃~+125℃
MSI-110810-SERIES Page 1/8
IDC1 :WK3255B+3265B (or equivalent)
Inductance Percent Test Resistance Rated DC Current
L(μH) Tolerance Frequency RDC(mΩ) IDC1(A) IDC2(A)
0.22 L,M 100kHz/1.0V 0.22 ±7% 60 45 R22
0.25 K,L,M 100kHz/1.0V 0.22 ±7% 50 45 R25
0.32 K,L,M 100kHz/1.0V 0.22 ±7% 40 45 R32
0.40 L,M 100kHz/1.0V 0.22 ±7% 36 45 R40
※ □ specify the inductance tolerance,K(±10%),L(±15%),M(±20%)
※ IDC1: Based on inductance change (△L/Lo:drop 20% Typ.)@ ambient temp. 25℃
IDC2: Based on temperature rise (△T: 40℃ TYP.)
Rated DC Current: The less value which is IDC1 or IDC2 .
RDC Measure point
Bottom view
(4) RELIABILITY TEST METHOD
MECHANICAL
TEST ITEM SPECIFICATION TEST DETAILS
Substrate bending
△L/Lo≦±5%
The sample shall be soldered onto the printed circuit board
in figure 1 and a load applied unitil the figure in the arrow
There shall be direction is made approximately 3mm.(keep time 30 seconds)
no mechanical PCB dimension shall the page 7/9
damage or elec- F(Pressurization)
trical damege.
Vibration
△L/Lo≦±5%
The sample shall be soldered onto the printed circuit board
and when a vibration having an amplitude of 1.52mm
There shall be and a frequency of from 10 to 55Hz/1 minute repeated should
no mechanical be applied to the 3 directions (X,Y,Z) for 2 hours each.
damage. (A total of 6 hours)
Solderability
New solder Flux (rosin, isopropyl alcohol{JIS-K-1522}) shall be coated
More than 90% over the whole of the sample before hard, the sample shall
then be preheated for about 2 minutes in a temperature of
130~150℃ and after it has been immersed to a depth 0.5mm
below for 3±0.2 seconds fully in molten solder M705 with
More than 90% of the electrode sections shall be couered
with new solder smoothly when the sample is taken out of
the solder bath.
Page-3/8