Mag Layers MHSC-2520C User Manual

(1) SHAPES AND DIMENSIONS
A: 2.90 Max. mm
(2) ELECTRICAL SPECIFICATIONS
(3) CHARACTERISTICS
B: 2.54 Max. mm C: 2.03 Max. mm D: 1.3 Typ. mm E: 0.45± 0.1 mm
SEE TABLE 1
TEST INSTRUMENTS L,Q : HP 4291B IMPEDANCE ANALYZER (or equivalent) SRF : ENA E5071B NETWORK ANALYZER (or equivalent) RDC : CHROMA MODEL 16502 MILLIOHMMETER (or equivalent)
(3)-1 Operate temperature range ...... 40℃~+125
(Including self temp. rise)
(3)-2 Storage temperature range ...... 40℃~+125
MAG.LAYERS
MHSC-2520C-SERIES Page-1/7
TABLE 1
MAGLAYERS
PT/NO. MHSC-2520C-4N7 MHSC-2520C-10N MHSC-2520C-12N MHSC-2520C-15N MHSC-2520C-18N MHSC-2520C-22N MHSC-2520C-27N MHSC-2520C-33N MHSC-2520C-39N MHSC-2520C-47N MHSC-2520C-56N MHSC-2520C-68N MHSC-2520C-82N MHSC-2520C-R10 MHSC-2520C-R12 MHSC-2520C-R15 MHSC-2520C-R18 MHSC-2520C-R22 MHSC-2520C-R27 MHSC-2520C-R33 MHSC-2520C-R39 MHSC-2520C-R47 MHSC-2520C-R56 MHSC-2520C-R62 MHSC-2520C-R68 MHSC-2520C-R75 MHSC-2520C-R82 MHSC-2520C-R86 MHSC-2520C-R91 MHSC-2520C-1R0 MHSC-2520C-1R2 MHSC-2520C-1R5 MHSC-2520C-1R8 MHSC-2520C-2R2 MHSC-2520C-2R7 MHSC-2520C-3R3 MHSC-2520C-3R9 MHSC-2520C-4R7 MHSC-2520C-5R6 MHSC-2520C-6R8
MHSC-2520C-8R2 MHSC-2520C-100
Inductance Percent L Freq. Quality Q Freq. SRF DCR IDC
L(nH) Tolerance (MHz) Min. (MHz) (MHz)Min. (Ω) Max. (mA) Max.
4.7 J,K 50 30 500 4300 0.065 1000 10 G,J,K 50 50 500 4100 0.08 1000 12 G,J,K 50 50 500 3300 0.09 1000 15 G,J,K 50 50 500 2500 0.10 1000 18 G,J,K 50 50 350 2500 0.11 1000 22 G,J,K 50 55 350 2400 0.12 1000 27 G,J,K 50 50 350 1600 0.13 1000 33 G,J,K 50 60 350 1600 0.14 1000 39 G,J,K 50 60 350 1500 0.15 1000 47 G,J,K 50 65 350 1500 0.16 1000 56 G,J,K 50 65 350 1300 0.18 1000 68 G,J,K 50 65 350 1300 0.20 1000 82 G,J,K 50 60 350 1000 0.22 1000
100 G,J,K 25 60 350 1000 0.56 650 120 G,J,K 25 60 350 950 0.63 650 150 G,J,K 25 45 100 850 0.70 580 180 G,J,K 25 45 100 750 0.77 620 220 G,J,K 25 45 100 700 0.84 500 270 G,J,K 25 45 100 600 0.91 500 330 G,J,K 25 45 100 570 1.05 450 390 G,J,K 25 45 100 500 1.12 470 470 G,J,K 25 45 100 450 1.19 470 560 G,J,K 25 45 100 415 1.33 400 620 G,J,K 25 45 100 375 1.40 300 680 G,J,K 25 45 100 375 1.47 400 750 G,J,K 25 45 100 360 1.54 360 820 G,J,K 25 45 100 350 1.61 400 860 G,J,K 25 45 100 330 1.65 400
910 G,J,K 25 35 50 320 1.68 380 1000 G,J,K 25 35 50 290 1.75 400 1200 G,J,K 7.9 35 50 250 2.0 310 1500 G,J,K 7.9 28 50 200 2.3 330 1800 G,J,K 7.9 28 50 160 2.6 300 2200 G,J,K 7.9 28 50 160 2.8 280 2700 G,J,K 7.9 22 25 135 3.2 290 3300 G,J,K 7.9 22 25 110 3.4 290 3900 G,J,K 7.9 20 25 100 3.6 260 4700 G,J,K 7.9 20 25 90 4.0 260 5600 G,J,K 7.9 18 7.9 40 4.2 240 6800 G,J,K 7.9 18 7.9 40 4.9 200 8200 G,J,K 7.9 18 7.9 25 6.0 170
10000 G,J,K 2.5 18 7.9 25 8.0 150
1. specify the inductance tolerance, G(±2%),J(±5%),K(±10%)
2. IDC : Based on temperature rise(T=15 Typ.) at 25 ambient.
MAG.LAYERS
MHSC-2520C-SERIES
Page-2/7
(4) RELIABILITY TEST METHOD
Item Specifications Test conditions
Solderability The metalized area must have 95% Dip pads in flux and dip in solder pot
minimum solder coverage. (96.5 Sn/3.5 Ag solder) at 255°C ±5°C. Resistance to There must be no case deformation Inductors shall be reflowed onto a PC board soldering heat or change in dimensions. using 96.5 Sn/3.5 Ag solder paste.
Inductance must not change more Solder process shall be at a maximum
than the stated tolerance. temperature of 260°C.
For 96.5 Sn/3.5 Ag solder paste:>217°C for 90 seconds
Vibration There must be no case deformation Solder specimen inductor on the test printed
or change in dimensions. circuit board.
Inductance must not change more Apply vibrations in each of the x,y and z directions
than the stated tolerance. for 2 house for a total of 6 hours.
Frequency : 10~50 Hz Amplitude : 1.5mm
High There must be no case deformation Inductors shall be subjected to temperature temperature or change in dimensions.
resistance
Static Inductors must not have a shorted Inductors shall be subjected to temperature Humidity or open winding.
Component Inductors shall be subjected to Inductors shall be reflow soldered (255°C adhesion 1.8Kg ±5°C for 10 seconds) to a tinned copper (push test) substrate. A force gauge shall be applied
Inductance must not change more Measure the test items after leaving the
than the stated tolerance. inductors at room temperature and humidity
Measure the test items after leaving the
125±2 for 50±12 hours.
for 2 hours.
85±2 and 90 to 95%RH. for ten 24-hours.
inductors at room temperature and humidity for 2 hours.
to the side of the component. The device must withstand the stated force without a failure of the termination.
MAG.LAYERS
MHSC-2520C-SERIES Page-3/7