SCOPE
:
This specification applies to the current type Radial Leaded Inductor
(1) SHAPES AND DIMENSIONS
(2) ELECTRICAL SPECIFICATIONS
SEE TABLE 1
(3) CHARACTERISTICS
for MCD-1012-SERIES
PRODUCT INDENTIFICATION MCD - 1012 - 101 J
① Product Code ② Dimensions Code ③ Inductance Code ④ Tolerance Code
A: 12.0 Max. mm B: 12.5 Max. mm C: 15±2.0 mm D: 5.0±0.5 mm E: φ0.8±0.1 mm F: 2.5 Max. mm
TEST INSTRUMENTS L : HP 4284A PRECISION LCR METER (or equivalent) RDC : CHROMA MODEL 16502 MILLIOHMMETER (or equivalent)
(3)-1 Ambient temperature ……......... +60℃ Max.
(3)-2 Operate temperature range ...... -40℃~+125℃
(Including self temp. rise)
(3)-3 Storage temperature range ...... -40℃~+125℃
MAG.LAYERS
MCD-1012-SERIES
Page 1/4
Page 2
TABLE 1
MAGLAYERS
Inductance Percent Test Resistance Rated DC Current
PT/NO.
MCD-1012-4R7□
MCD-1012-100□ MCD-1012-150□ MCD-1012-220□ MCD-1012-330□ MCD-1012-101□ MCD-1012-151□ MCD-1012-471□ MCD-1012-681□ MCD-1012-821□ MCD-1012-102□
※ □ specify the inductance tolerance,J(±5%),K(±10%),M(±20%) ※ IDC1:Based on inductance change (△L/Lo:drop 10% Max.) @ambient temperature 25℃
IDC2:Based on temperature rise (△T: 40℃ TYP.)
L(μH) Tolerance Frequency RDC(Ω)Max. IDC1(A) IDC2(A)
4.7 M 100kHz/0.25V 15.0m 9.0 6.40 10 K,M 100kHz/0.25V 21.0m 7.0 5.50 15 K,M 100kHz/0.25V 31.2m 5.0 4.20 22 K,M 100kHz/0.25V 44.1m 4.5 3.80 33 K,M 100kHz/0.25V 66.5m 3.5 3.10
100 J,K 100KHz/0.25V 0.15 2.2 2.00 150 K,M 100KHz/0.25V 0.21 1.9 1.80 470 K,M 100KHz/0.25V 0.70 1.0 0.80 680 K,M 100KHz/0.25V 0.96 0.8 0.70 820 K,M 100KHz/0.25V 1.20 0.75 0.65
1000 J,K,M 100KHz/0.25V 1.50 0.65 0.60
Rated DC Current: The less value which is IDC1 or IDC2.
MAG.LAYERS
MCD-1012-SERIES
Page-2/4
Page 3
(4) RELIABILITY TEST METHOD
MECHANICAL
NO. ITEMS
1 Solderability test
2 lead tensile 1.0 Kg MIN. The lead of product is pulled with a load of
strength test 1.0kg mininum until lead breakdown. The tensile
SPECIFICATIONS
More than 90% of the termnial electrode should be covered with solder.
CONDITIONS
Dipping: 245 ± 5 ℃ , 3 ± 1 seconds
force shall be recorded.
3 Vibration test
4 Soldering heat Visual:OK The leads of product are dipped into a solder pot
resistance test Circuit:OK
ENVIRONMENTAL
NO. ITEMS
1 Humidity
endurance test
2 High temp
endurance test
△L/L≦±7% Visual:OK
SPECIFICATIONS CONDITIONS
△L/L≦±5% The product is placed in a chamber of 40±2℃,
△L/L≦±5%
The product is fixed ento the vibration with amplitude of 1.52m/m at a frequency of 10~55Hz sweeping for lmin. The vibration is done at X,Y, Z direction respectively for 2 houes, totally 6 hours.
of 260±5℃ for a duration of 10±1sec. Nothing particular on visual and open circuitry as a result of ore testing.
90~95%RH for 96 hours. Measurement is done after the reaovery of 4~24 hours. The product is placed in a chamber of 80±2℃, for 72 hours. Measurement is done after recovery of 4~24 hours.
3 Low temp test
4 Thermal shock
test
MAG.LAYERS
△L/L≦±5%
△L/L≦±5%
The product is placed in a chamber of -40±2℃, for 96 hours. Measurement is done after recovery of 4~24 hours.
The specimens are placed in a chamber and the temp is then lowered to -20±2℃ for one hour. The temp will raised to +80±2℃ for one hour. This constitues one cycle. Ten cycles of such testing shall be completed. Measurement is made after recovery for 4~24 hours from the completion of testing.
MCD-1012-SERIES
Page-3/4
Page 4
(5) PACKAGE SPECIFICATION (mm)
MAG.LAYERS
MCD-1012-SERIES
Page-4/4