Magimix LE BLENDER User Manual

Le
Blender
INSTRUCTION NOTICE AND RECIPES P. 24
GEBRUIKSAANWIJZING DE RECEPTEN P. 13
MODE D’EMPLOI ET RECETTES P. 2
24
L
Electrical Instructions
WARNING :
a plug with bared flexible cord is hazardous if engaged in a live socket. If the fitted plug has been cut from the power supply cord, it should be destroyed and replaced with an appropriate three pin plug in accordance with the follo­wing code : BLUE : neutral
BROWN : live
GREEN/YELLOW : earth
The wire which is coloured BLUE must be connected to the terminal in the plug which is marked with the letter "N" or coloured BLUE or BLACK.
The wire which is coloured BROWN must be connected to the terminal in the plug which is marked with the letter "L" or coloured BROWN or RED.
The wire which is coloured YELLOW should be connected to the terminal marked with the letter "E", or by the earth symbol or coloured GREEN or GREEN/YELLOW.
ELECTRICAL INSTRUCTIONS
• Before using your Blender ensure that the voltage indicated on the base corresponds with the mains voltage in your home.
• Before starting, make sure that the Blender switch is in off position “O”.
Before placing the jug on the motor base, make sure that the motor is turned off and it is at a complete stop. Place the jug assembly on the base so that it is firmly seated and not tilted to one side.
Do not place the jug on the base or take it off while the motor is running. To do so may damage the drive shaft or blending assembly.
25
Put ingredients into the jug and put the lid on. Always add liquids ingredients first. Hold jug handle with one hand while blending. Use the special measuring cap opening for introdu­cing ingredients when the machine is in use.
Always operate Blender with lid in place.
The Blender is fitted with a 2 speed control switch. Use speed “1” for all normal blending preparations and use high speed “2” when a fine emulsion is required.
Speed 1 (19.000 rpm) for normal work Speed 2 (22.000 rpm) for a fine emulsion
Hot blending instructions. To minimize possibility of spillage it is recommended that you limit the volume to one-half pint, completely remove the measuring-cap from the lid (this will allow expanding air present inside jug) and always start blending on lowest speed 1, then progress to desired speed 2.
When blending hot liquids, remove measuring cap.
- Always operate the Blender with lid in place.
- To protect against electrical hazards, do not immerse the motor base in water or in other liquid.
- Unplug from socket when not in use.
- Do not operate with a damaged cord or plug or after the unit malfunctions. Return it to the nearest authorized service facility for repair. Special tools are needed.
- Do not use outdoors.
- Keep hand and ustensils out of jug while blending.
- Handle the blade carefully.
IMPORTANT
26
We reserve the right to alter at any time without notice the technical specifications of this appliance.
© All rights reserved for all countries by Magimix.
UNITED KINGDOM AND IRELAND
115 A High Street
Godalming, Surrey GU7 1AQ
Telephone: 0483 427411 - Fax: 0483 427414
HOW TO DISASSEMBLE AND CLEAN
The blade can not be removed from the bowl. Parts marked “*” are dishwasher safe, others must be hand washed. After cleaning and drying, reas­semble as shown on drawing.
To clean the motor base, unplug the power cord, wipe the surface with a damp cloth first, then with a dry cloth.
CIRCUIT BREAKER OPERATION
You will find a small, square, red plastic button located on the underside of the motor base of some models.
This is the reset button for a circuit breaker which prevents the motor from overheating in the case of an overload.
If an overload occurs, the circuit breaker will shut off the motor and cause the red button to protrude slightly from its normal position.
To reset the circuit breaker, and resume operation, do the following : 1 - Set the power switch to its off (O) position. 2 - Unplug the power cord from electrical outlet. 3 - Determine the reason for the overload, and eliminate the cause (for example : reduce
the amount of material being processed). 4 - Push the red reset button back in to its normal position. 5 - Plug the power cord back into electrical outlet. 6 - Resume normal operation.
Lid
Measuring Cap
Jug
*
Motor base
Loading...