Magicfx STADIUMBLASTER MFX0803 User And Installation Manual

USER AND INSTALLATION MANUAL
ENGLISH
STADIUM
BLASTER.
®
CONFETTI & STREAMER FX
PAR T01104
rev 01-01

DISCLAIMER

WARNING
© 2019 MAGICFX All rights reserved.
Nothing from this publication may be copied, reproduced and/or published by means of printing, photocopying or by any other means, without the prior written approval of MAGIC FX.
MAGIC FX reserves the right to modify specications stated in this manual.
Read this manual carefully before installing and/or using this product. Failure to read the manual and to follow the printed instructions may lead to personal injury and/or damage to the product.
®

TRADEMARKS

Any brand names mentioned in this manual are registered trademarks of their respective owners.

LIABILITY

MAGIC FX accepts no liability for claims from third parties arising from unauthorised use, use other than that stated in this manual, and use other than in accordance with the General Conditions registered at the Chamber of Commerce.
We further refer to the General Conditions. These are available on request, free of charge.
Although considerable care has been taken to ensure a correct and comprehensive description of all relevant components, the manual may nonetheless contain errors and inaccuracies.
Should you detect any errors or inaccuracies in the manual, we would be grateful if you would inform us. This helps us to further improve our documentation.
2 MAGICFX® STADIUMBLASTER — User and Installation Manual
TABLE OF CONTENTS
Disclaimer 2 Trademarks 2 Liability 2 Foreword 4 Language 4 Revision table 4
1 Meet the MAGICFX® STADIUMBLASTER! 5
1.1 Main parts 5
1.2 Technical data 6
1.3 Productidentication 7
1.4 Accessories 7
1.5 Confetti 7
1.6 DMX control 8
1.7 Displaypanel 8
1.8 RDMcapability 10
2 Blastsafely! 11
2.1 Generalsafetyrules 11
2.2 CO2 11
2.3 Indoor use 12
2.4 Rigging 12
2.5 Noise level 12
2.6 Safetysymbols 13
2.7 Precautionsforoperation 13
3 Let’s blast! 14
3.1 Installthemachine 14
3.2 Fillwithconfettibeforeeachblast 20
3.3 Blastmanually 21
3.4 Connect 24 V Control 23
3.5 Blast with 24 V Control 23
3.6 Connect power and setup DMX 24
3.7 SetupmultiplemachinesinasequencewithDMX 25
3.8 Blast with DMX 25
3.9 Replace a CO
cylinder 26
2
3.10 Cleanup 28
4 Maintenance 34
5 Troubleshooting 34
6 Correct disposal 34
7 ECDeclarationofConformity 35
MAGICFX® STADIUMBLASTER — User and Installation Manual 3

FOREWORD

Congratulations! You have bought a great new product from MAGIC FX.
This manual contains all information required for the intended use of the equipment. Deviation from the described intended use can result in a hazardous situation and/or property damage.
This manual includes notes and warnings on safe operation of the equipment. These notes and warnings are accompanied by the following icons. Read them attentively!
DANGER
WARNING
CAUTION
NOTICE
Indicates a hazardous situation that, if not avoided, will result in death or serious injury. This signal word is to be limited to the most extreme situations.
Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
Indicates information considered important, but not hazard­related (e.g. messages relating to property damage).

LANGUAGE

This document contains the original instructions in English. In case you require other languages please contact MAGIC FX.

REVISION TABLE

Doc nr Revision Date Description Author Approved
PART01104 01-00 13-2-2017 Initial release TFR TVA
PART01104 01-01 1-8-2019 A4 to A5 format TFR TVA
4 MAGICFX® STADIUMBLASTER — User and Installation Manual

1 MEET THE MAGICFX® STADIUMBLASTER!

DISPLAY AND BUTTONS
POWER INPUT & OUTPUT
The MAGICFX® STADIUMBLASTER is a special eects machine that launches confetti into the air up to a height of 12 metres.
®
The MAGICFX
into the woofer through small holes. This creates a Venturi eect that draws the confetti continuously from the hopper, out of the woofer and into the air. The eect is
accompanied by a strong hissing sound. If liquid CO2 is applied, a white plume of smoke will be visible.
The MAGICFX® STADIUMBLASTER is outtted for operation:
• by hand with the manual CO2 valve;
• with a 24 V controller;
• with DMX and optionally RDM.
With DMX you can operate multiple machines in a sequence.

1.1 MAIN PARTS

STADIUMBLASTER is equipped with a CO2 powered woofer. CO2 is blown
WOOFER
DMX INPUT & OUTPUT
FLIGHTCASE
CO INPUT
(5-POLE)
(100  250 Vac)
HOPPER
MANUAL CO VALVE
FX LED INDICATOR
BOTTOM CABINET
24 V INPUT
Main parts
MAGICFX® STADIUMBLASTER — User and Installation Manual 5

1.2 TECHNICAL DATA

Product Product Name MAGICFX® STADIUMBLASTER
Product Code MFX0803
Product Type CONFETTI & STREAMER FX
Main
Dimensions
Weight Weight 84.3 kg 185.8 lb
Environment Minimum Temperature -20 °C -4 °F
Electrical Voltage Input (Vac) 100 – 250 Vac
Controlling Control Options DMX / Manual valve / 24 Vdc
Conguring Congure Options On Device & RDM
Usage Consumable(s) MAGICFX
Length 800 mm 31.5 in
Width 600 mm 23.6 in
Height 1100 mm 43.3 in
Maximum Temperature 70 °C 158 °F
Humidity (Relative) 20% to 90% (non condensing)
IEC 60529 (IP) Rating IP13
Voltage Frequency 50 – 60 Hz
Power Consumption (Vac) 20 W
Power Connector (Vac) Neutrik
®
powerCON TRUE1 (in & out)
Voltage Input (Vdc) 18 – 36 Vdc
Power Consumption (Vdc) 17 W
Power Connector (Vdc) Banana Plug & Wire
Control Protocols DMX512-A (ANSI E1.11)
RDM (ANSI E1.20)
Control Connectors Neutrik
®
5 pole male / female XLR
®
CONFETTI
Consumable Consumption Depends on type of confetti, see
Section 1.5
Propellant Liquid or Gaseous CO
2
Propellant Connector CO2 Quick Connector 3/8”
Propellant Consumption 0.5 L/s
Technical data
6 MAGICFX® STADIUMBLASTER — User and Installation Manual

1.3 PRODUCT IDENTIFICATION

Type plate

1.4 ACCESSORIES

Code Product Included
MFX1114 CO₂ High Pressure Hose 3/8 Male - Female, 1.25 m MFX1105 CO₂ High Pressure Hose 3/8 Male - Female, 2 m MFX1106 CO₂ High Pressure Hose 3/8 Male - Female, 3 m X MFX1108 CO₂ High Pressure Hose 3/8 Male - Female, 10 m MFX1109 CO₂ High Pressure Hose 3/8 Male - Female, 15 m MFX1110 CO₂ 90 Degrees Connector 3/8 MFX1103 CO₂ Bottle to Hose Connector X MFX1115 CO₂ Bottle to Hose Connector 90 Degrees
MFX0313 Schuko to Neutrik
®
powerCON TRUE1 - cable 1.5 m X
Accessories

1.5 CONFETTI

The MAGICFX® STADIUMBLASTER can be set in 5 dierent angles between 45° and 90°. The output height and output distance depends on the type of confetti and the set angle. The maximum load per blast also depends on the type of confetti. Check the following table.
Typeofconfetti Max. load per blast Output height Output distance
Metallic confetti 20 kg 12 m 25 m
Paper confetti 10 kg 12 m 25 m
Snow/Powder confetti 5 kg 12 m 25 m
Confetti types and related loads and output
NOTICE
Wind and other weather circumstances will inuence the output
height and output distance of the confetti. The given values are estimated values.
MAGICFX® STADIUMBLASTER — User and Installation Manual7

1.6 DMX CONTROL

When connected to DMX the MAGICFX® STADIUMBLASTER is controlled with 1 safety
address and 1 operational address:
DMX Address Address range
Safety 1 – 512
Start 1 – 512
DMX addresses
The safety address cannot be the same as (one of) the operational address(es).
Operating of these addresses results in the following:
DMX Address DMXValue(decimal) Result
0 99 Device disabled
Safety
Start (output)
When you link multiple machines with DMX, we advise you to use the same Safety address for all machines.
100 155 Device enabled
156 255 Device disabled
0 199 Valve closed
200 255 Valve open
Operation of the DMX addresses
CAUTION
Always plug in a DMX Terminator into the DMX output of the nal
unit in the control sequence. Using a DMX Terminator improves signal reliability.
1.7 DISPLAY PANEL
MAIN MENU
DMX/RDM SETTINGS
BACK PREV NEXT
8 MAGICFX® STADIUMBLASTER — User and Installation Manual
SELECT

Display panel

The display panel is located on the backside of the MAGICFX® STADIUMBLASTER. Check the following menu structure for all options in the menu. Use the buttons for
navigation and selection. The le-hand LED blinks red when DMX is active. The right-
hand LED continuously lights red when an error is present.
DMX Start Address (1 – 512)
Lock/Unlock Controller
(press and hold for 5 seconds)
Idle Display
DMX Safety Address (1 – 512)
Reset Errors
DMX Footprint (Fixed)
DMX/RDM Settings
RDM (ON/OFF)
Display Dimmer (ON/OFF)
(dims aer 30 seconds of button inactivity)
Configuration
Main Menu
Factory Defaults (YES/NO)
Error History
Type (Alarm/Error)
Serial Number
Information
Unique ID
Soware Version
Soware CRC
Bootloader CRC
Build Date
Uptime (DDDD:HH:MM:SS)
Effect Time (DDDD:HH:MM:SS)
MAGICFX® STADIUMBLASTER User and Installation Manual 9
Menu structure

1.8 RDM CAPABILITY

Remote Device Management Protocol (RDM) is an enhancement of the DMX512
communication protocol. RDM can be used for conguration and status monitoring
while DMX512 takes care of the default controlling.
For RDM you will need a RDM compatible controller. The following RDM parameters
®
are supported by the MAGICFX
STADIUMBLASTER.
ParameterID Discovery GET SET
DISC_UNIQUE_BRANCH X
DISC_MUTE X
DISC_UN_MUTE X
DEVICE_INFO X
SUPPORTED_PARAMETERS X
SOFTWARE_VERSION_LABEL X
DEVICE_MODEL_DESCRIPTION X
MANUFACTURER_LABEL X
SLOT_DESCRIPTION X
DMX_PERSONALITY_DESCRIPTION X
SENSOR_DEFINITION X
SENSOR_VALUE X
DMX_START_ADDRESS X X
IDENTIFY_DEVICE X X
DEVICE_LABEL X X
FACTORY_DEFAULTS X X
DMX_PERSONALITY X X
RESET_DEVICE X
RDM parameters
RDM parameters are subject of change due to soware updates. Contact MAGIC FX
for the latest information and updates.
10  MAGICFX® STADIUMBLASTER User and Installation Manual

2 BLAST SAFELY!

The MAGICFX® STADIUMBLASTER has been designed and constructed in such a manner that it can be used safely. This applies to the use, the circumstances and the regulations as described in this documentation. Reading this documentation and following the instructions are therefore necessary for everyone who is authorised to work with the MAGICFX
The MAGICFX® STADIUMBLASTER must be used in surroundings that:
• Have a stable temperature of between -20 and 70 °C.
• Have a relative humidity degree between 20 % and 90 % (non condensing).
• Are free of dust, corrosive gases and high concentrations of organic vapours.
• Are not situated in the vicinity of a source of vibration.

2.1 GENERAL SAFETY RULES

• Only authorised persons may carry out work with the MAGICFX® STADIUMBLASTER.
• Do not use the MAGICFX® STADIUMBLASTER if there are people or animals in the direct output.
• Make sure that children, unauthorised people and animals do not obtain access to the MAGICFX® STADIUMBLASTER.
• Make sure there are no freestanding objects or objects that can be damaged by the MAGICFX® STADIUMBLASTER within the output distance.
• Do not connect more units to a single electrical circuit than the installed fuse is able to handle. (Calculate the summed load with the electrical data from Chapter 1)
• Do not remove any safeguards, safety caps and safety symbols.
• All required safety devices must be in good condition and function properly.
Ensure sucient lighting of the surroundings.
• Keep the workplace clean.
®
STADIUMBLASTER.

2.2 CO2

The MAGICFX® STADIUMBLASTER uses liquid or gaseous CO2 as input. The application of CO2 involves serious risks. Make sure that you are well informed on these risks before installation and/or operation. Always use approved CO2 cylinders, hoses and connections. Always consult your CO2 supplier for regulations and instructions on safe installation and use.
MAGIC FX is not liable for unsafe situations, accidents and damage that are the result of incorrect working with CO2 and CO2 cylinders.
MAGICFX® STADIUMBLASTER — User and Installation Manual 11
WARNING
Inadequate installation and/or operation of a CO2 powered machine and CO2 cylinders can lead to death or serious injury. Always follow the instructions from this manual, from your CO2 supplier and from local authorities.

2.3 INDOOR USE

The MAGICFX® STADIUMBLASTER is designed for outdoor use and use in well-ventilated indoor spaces. When used indoors, make sure you take the necessary preparations.
These preparations could include, but are not limited to:
• Consulting your CO2 supplier.
• Calculating the reduction of oxygen for the indoor space.
• Checking the location for spots where CO2 could accumulate and taking preventive actions.
• Installing CO2 monitoring devices that will warn for hazardous CO2 levels.
DANGER
Do not use the MAGICFX® STADIUMBLASTER in poorly ventilated
conned spaces. Exposure to high levels of CO2 gas can cause
symptoms like headache, nausea, loss of consciousness or even death.

2.4 RIGGING

Please follow the European and national guidelines for safe rigging and trussing.

2.5 NOISE LEVEL

The environmental noise level as measured at the ear is 97 dB(A). This level of noise is only reached during the short instances that the CO2 output is active. Therefore hearing protection is not necessary.
WARNING
Do not operate the MAGICFX® STADIUMBLASTER close to yourself or to others for a long period of time. If you experience any hearing loss or ringing in the ears, you should immediately stop using the unit.
12 MAGICFX® STADIUMBLASTER — User and Installation Manual

2.6 SAFETY SYMBOLS

4
5
˚
Symbol Meaning
Read the manual carefully before use!

2.7 PRECAUTIONS FOR OPERATION

Safety symbols
WARNING
WARNING
CAUTION
WARNING
WARNING
Using a damaged or an improper installed machine can lead to death, serious injury or property damage. Always inspect the machine thoroughly before operation.
Missing or obscured safety symbols on the machine can lead to death, serious injury or property damage. Make sure all safety symbols are correctly in place and visible, see Section 2.6.
A missing or loose-tted woofer can lead to injury. Make sure that
the woofer is correctly in place on the bayonet connection and secured with the safety steel.
Make sure there are no objects near the output that can be damaged or overthrown by the MAGICFX® STADIUMBLASTER.
Always create a safety zone around the MAGICFX® STADIUMBLASTER and its output according to the following picture.
2 m
4 m
MAGICFX® STADIUMBLASTER — User and Installation Manual 13

3 LET’S BLAST!

3.1 INSTALL THE MACHINE

1 Bring the cased MAGICFX® STADIUMBLASTER to the desired location.
2 Unlock and remove the top cover.
14 MAGICFX® STADIUMBLASTER — User and Installation Manual
3 Unlock and remove the cover from the bottom cabinet.
4 Take out the woofer.
MAGICFX® STADIUMBLASTER — User and Installation Manual 15
5 Screw the woofer rmly onto the bayonet socket of the hopper until it locks in
place.
6 Secure the woofer with the safety steel.
16 MAGICFX® STADIUMBLASTER — User and Installation Manual
7 Optionally you can set the hopper with the attached woofer in one of the
5 pre-set angles.
8 Place the MAGICFX® STADIUMBLASTER in its nal position and set the brakes.
9 Take the necessary safety precautions, see Section 2.7.
MAGICFX® STADIUMBLASTER — User and Installation Manual17
10 Make sure the manual CO2 valve is in CLOSED position.
11 Connect the CO2 hose to the CO2 quick connector.
18 MAGICFX® STADIUMBLASTER — User and Installation Manual
12 Connect a CO₂ Bottle to
Hose Connector to a CO2 cylinder.
13 Connect the CO2 hose to the
CO₂ Bottle to Hose
Connector on the CO2 cylinder.
14 Open the CO2 cylinder.
15 In case of multiple machines: Repeat steps 1 – 14 for each machine.
MAGICFX® STADIUMBLASTER — User and Installation Manual 19

3.2 FILL WITH CONFETTI BEFORE EACH BLAST

1 Unlock and open the lid of the hopper.
2 Fill the hopper with confetti. Check Section 1.5 for the maximum amount per
type of confetti.
20  MAGICFX® STADIUMBLASTER User and Installation Manual
3 Close and lock the lid of the hopper.
4 In case of multiple machines: Repeat steps 1 – 3 for each machine.

3.3 BLAST MANUALLY

1 Make sure that the safety zone is free from persons and hazardous objects.
2 When it’s time to blast, move the manual CO2 valve in OPEN position.
NOTICE
The best eect results are achieved when you open the lid just
before you start blasting. Make sure that no foreign objects will
enter the hopper and close the lid again aer the eect.
MAGICFX® STADIUMBLASTER — User and Installation Manual 21
3 Enjoy the view!
4 When the hopper is out of confetti, move the manual CO2 valve back in
CLOSED position.
22 MAGICFX® STADIUMBLASTER — User and Installation Manual

3.4 CONNECT 24 V CONTROL

24 V 24 V
1. Connect two cables to the 24 V input.
2. Connect the other ends of the cables to your controller.
NOTICE
NOTICE
No additional power source is needed. The controller provides power to the MAGICFX® STADIUMBLASTER to open and close the output valve.
The FX LED indicator and the display and buttons are inactive when control is applied. The controller only powers the output valve.

3.5 BLAST WITH 24 V CONTROL

1. Make sure that the safety zone is free from persons and hazardous objects.
2. When it’s time to blast, continuously, enable the output on your 24 V controller
and make sure to produce a continuous pulse.
NOTICE
3. Enjoy the view!
4. When the hopper is out of confetti, disable the output on your 24 V controller.
The best eect results are achieved when you open the lid just
before you start blasting. Make sure that no foreign objects will
enter the hopper and close the lid again aer the eect.
MAGICFX® STADIUMBLASTER — User and Installation Manual 23

3.6 CONNECT POWER AND SETUP DMX

POWER IN POWER OUT
DMX
5-pole female
PowerCon TRUE1 female
DMX IN DMX OUT
POWER
1. Connect a power cable with a Powercon TRUE1 Female connector to the power input.
2. Connect the other end of the power cable to a 100 – 250 Vac (50 – 60 Hz) power source.
3. Connect the female connector of a 5-pole DMX cable in the DMX input.
4. Connect the other end of the DMX cable to your DMX controller.
5. Use the display and buttons or a RDM controller to assign DMX addresses, see
chapter 1.
CAUTION
Always plug in a DMX Terminator into the DMX output. Using a DMX Terminator improves signal reliability.
24 MAGICFX® STADIUMBLASTER User and Installation Manual

3.7 SETUP MULTIPLE MACHINES IN A SEQUENCE WITH DMX

5-pole male
5-pole female
DMX
DMX IN DMX OUT
POWER IN POWER OUT
PowerCon TRUE1 male
POWER
PowerCon TRUE1 female
1. Connect a power link cable to the power output.
2. Connect the other end to the power input of the next machine.
3. Connect a DMX cable to the DMX output.
4. Connect the other end to the DMX input of the next machine.
5. Use the buttons or a RDM controller to assign DMX addresses, see chapter 1.
6. Repeat step 1 to 5 for each subsequent machine.
CAUTION
Always plug in a DMX Terminator into the DMX output of the nal
unit in the control sequence. Using a DMX Terminator improves signal reliability.

3.8 BLAST WITH DMX

1. Make sure that each safety zone is free from persons and hazardous objects.
2. Activate the Safety address. The FX LED indicator on each machine lights up.
3. When it’s time to blast, activate the Start address.
NOTICE
The best eect results are achieved when you open the lid just
before you start blasting. Make sure that no foreign objects will
enter the hopper and close the lid again aer the eect.
DMX IN DMX OUT
POWER IN POWER OUT
4. Enjoy the view!
5. Deactivate the Start address when the hopper is out of confetti.
MAGICFX® STADIUMBLASTER — User and Installation Manual 25

3.9 REPLACE A CO2 CYLINDER

1 Make sure that:
a) The manual CO
in CLOSED position.
valve is
2
b) The DMX Safety address
is not activated (FX LED indicator is dimmed).
c) The 24 V controller (if
used) is not powered.
2 Close the CO2 cylinder.
3 Move the manual CO2 valve
in OPEN position to release the pressure from the system.
4 Move the manual CO2 valve
back in CLOSED position.
26 MAGICFX® STADIUMBLASTER — User and Installation Manual
5 Disconnect the CO2 hose from the
CO2 Bottle to Hose Connector on the CO2 cylinder.
6 Remove the CO2 Bottle to Hose
Connector from the cylinder.
7 Connect a CO2 Bottle to Hose
Connector to a new CO2 cylinder.
MAGICFX® STADIUMBLASTER — User and Installation Manual27
8 Connect the CO2 hose to the CO2
Bottle to Hose Connector on the new CO2 cylinder.
9 Open the CO2 cylinder.
10 In case of multiple machines: Repeat steps 1 – 9 for each machine.

3.10 CLEAN UP

1 Deactivate the Safety address
(FX LED indicator on each machine dims).
2 Disconnect any 24 V, DMX and
power cable(s).
3 Close the CO
28 MAGICFX® STADIUMBLASTER — User and Installation Manual
cylinder.
2
4 Move the manual CO2 valve
in OPEN position to release the pressure from the system.
5 Disconnect the CO2 hose
from the CO2 quick connector.
6 Disconnect the CO2 hose from the
CO2 Bottle to Hose Connector on the CO2 cylinder.
MAGICFX® STADIUMBLASTER User and Installation Manual 29
7 Remove the CO2 Bottle to Hose
Connector from the cylinder.
8 Wait until the ice crust on the output has melted.
9 In case you have set the hopper under an angle: Position the hopper back in
horizontal position (position 1).
30  MAGICFX® STADIUMBLASTER — User and Installation Manual
10 Remove the safety steel.
11 Remove the woofer.
MAGICFX® STADIUMBLASTER — User and Installation Manual 31
12 Remove the woofer.
13 Place and lock the cover of
the bottom cabinet.
14 Unlock and open the lid
from the hopper.
32 MAGICFX® STADIUMBLASTER — User and Installation Manual
15 Remove remaining confetti
from the hopper.
16 Close and lock the lid from
the hopper.
17 Place and lock the top
cover.
18 Release the brakes.
MAGICFX® STADIUMBLASTER — User and Installation Manual 33

4 MAINTENANCE

To achieve the maximum service life of the MAGICFX® STADIUMBLASTER you must regularly clean the MAGICFX
Contact MAGIC FX if the MAGICFX® STADIUMBLASTER is not functioning correctly.
DANGER
®
STADIUMBLASTER and test if it is functioning correctly.
Do not replace parts yourself; always consult MAGIC FX.

5 TROUBLESHOOTING

Always contact MAGIC FX if any malfunctions or errors occur that cannot be solved with the instructions as described in this manual.

6 CORRECT DISPOSAL

This symbol on the product and / or accompanying documents means that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling, please take this product to designated collection points where it will be accepted free of charge.
Alternatively, in some countries you may be able to return your products to your local retailer upon purchase of an equivalent new product.
Disposing of this product correctly will help save valuable resources and prevent any
potential negative eects on human health and the environment, which could
otherwise arise from inappropriate waste handling.
Please contact your local authority for further details of your nearest designated collection point.
Penalties may be applicable for incorrect disposal of this waste, in accordance with your national legislation.
34 MAGICFX® STADIUMBLASTER User and Installation Manual

7 EC DECLARATION OF CONFORMITY

DECLARATION OF CONFORMITY
According to Annex III A Low Voltage Directive 2014/35/EU + Machinery Directive 2006/42/EC
MAGIC FX B.V. declares as manufacturer and composer of the technical construction file that the product with the following specifications:
Name machine : STADIUMBLASTER Type : MFX0803 Voltage : 100-250Vac 50-60Hz Serial number : on product Year of construction : on product
Is in conformity with the minimal safety regulations as stated in the following directive(s):
EMC (2014/30/EC) ElectroMagnetic Compatibility
RoHS (2011/65/EU) Restriction of the use of certain Hazardous Substances
WEEE (2012/19/EU) Waste Electrical & Electronic Equipment
The following harmonized standards were applied:
NEN-EN-ISO 12100:2010 Safety of machinery - General principles for design - Risk assessment and risk reduction.
NEN-EN-IEC 60204-1:2006, Safety of machinery - Electrical equipment of machines - Part 1: General requirements.
NEN-EN-IEC 61000-6-3:2007/A1:2011, Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments.
Original declaration of conformityTranslation of the original declaration of conformity
Name manufacturer : MAGIC FX BV Address : Schouwrooij 27, 5281 RE BOXTEL Country : The Netherlands
CEO : B. Veroude Date : 17-01-2017
Signature :
MAGICFX® STADIUMBLASTER — User and Installation Manual 35
WWW.MAGICFX.EU
Loading...