Nothing from this publication may be copied, reproduced and/or published by
means of printing, photocopying or by any other means, without the prior written
approval of MAGIC FX.
MAGIC FX reserves the right to modify specications stated in this manual.
Read this manual carefully before installing and/or using this
product. Failure to read the manual and to follow the printed
instructions may lead to personal injury and/or damage to the
product.
®
TRADEMARKS
Any brand names mentioned in this manual are registered trademarks of their
respective owners.
LIABILITY
MAGIC FX accepts no liability for claims from third parties arising from unauthorised
use, use other than that stated in this manual, and use other than in accordance with
the General Conditions registered at the Chamber of Commerce.
We further refer to the General Conditions. These are available on request, free of
charge.
Although considerable care has been taken to ensure a correct and comprehensive
description of all relevant components, the manual may nonetheless contain errors
and inaccuracies.
Should you detect any errors or inaccuracies in the manual, we would be grateful if
you would inform us. This helps us to further improve our documentation.
2 MAGICFX® STADIUMBLASTER — User and Installation Manual
MAGICFX® STADIUMBLASTER — User and Installation Manual 3
FOREWORD
Congratulations! You have bought a great new product from MAGIC FX.
This manual contains all information required for the intended use of the equipment.
Deviation from the described intended use can result in a hazardous situation and/or
property damage.
This manual includes notes and warnings on safe operation of the equipment. These
notes and warnings are accompanied by the following icons. Read them attentively!
DANGER
WARNING
CAUTION
NOTICE
Indicates a hazardous situation that, if not avoided, will result in
death or serious injury. This signal word is to be limited to the most
extreme situations.
Indicates a hazardous situation that, if not avoided, could result
in death or serious injury.
Indicates a hazardous situation that, if not avoided, could result
in minor or moderate injury.
Indicates information considered important, but not hazardrelated (e.g. messages relating to property damage).
LANGUAGE
This document contains the original instructions in English. In case you require other
languages please contact MAGIC FX.
REVISION TABLE
Doc nrRevision DateDescription Author Approved
PART0110401-0013-2-2017 Initial release TFRTVA
PART0110401-011-8-2019A4 to A5 formatTFR TVA
4 MAGICFX® STADIUMBLASTER — User and Installation Manual
1 MEET THE MAGICFX® STADIUMBLASTER!
DISPLAY AND BUTTONS
POWER INPUT & OUTPUT
The MAGICFX® STADIUMBLASTER is a special eects machine that launches confetti
into the air up to a height of 12 metres.
®
The MAGICFX
into the woofer through small holes. This creates a Venturi eect that draws the
confetti continuously from the hopper, out of the woofer and into the air. The eect is
accompanied by a strong hissing sound. If liquid CO2 is applied, a white plume of
smoke will be visible.
The MAGICFX® STADIUMBLASTER is outtted for operation:
• by hand with the manual CO2 valve;
• with a 24 V controller;
• with DMX and optionally RDM.
With DMX you can operate multiple machines in a sequence.
1.1 MAIN PARTS
STADIUMBLASTER is equipped with a CO2 powered woofer. CO2 is blown
WOOFER
DMX INPUT & OUTPUT
FLIGHTCASE
CO₂ INPUT
(5-POLE)
(100 250 Vac)
HOPPER
MANUAL CO₂ VALVE
FX LED INDICATOR
BOTTOM CABINET
24 V INPUT
Main parts
MAGICFX® STADIUMBLASTER — User and Installation Manual 5
Consumable ConsumptionDepends on type of confetti, see
Section 1.5
PropellantLiquid or Gaseous CO
2
Propellant ConnectorCO2 Quick Connector 3/8”
Propellant Consumption0.5 L/s
Technical data
6 MAGICFX® STADIUMBLASTER — User and Installation Manual
1.3 PRODUCT IDENTIFICATION
Type plate
1.4 ACCESSORIES
CodeProductIncluded
MFX1114CO₂ High Pressure Hose 3/8 Male - Female, 1.25 m
MFX1105CO₂ High Pressure Hose 3/8 Male - Female, 2 m
MFX1106CO₂ High Pressure Hose 3/8 Male - Female, 3 mX
MFX1108CO₂ High Pressure Hose 3/8 Male - Female, 10 m
MFX1109CO₂ High Pressure Hose 3/8 Male - Female, 15 m
MFX1110CO₂ 90 Degrees Connector 3/8
MFX1103CO₂ Bottle to Hose ConnectorX
MFX1115CO₂ Bottle to Hose Connector 90 Degrees
MFX0313Schuko to Neutrik
®
powerCON TRUE1 - cable 1.5 mX
Accessories
1.5 CONFETTI
The MAGICFX® STADIUMBLASTER can be set in 5 dierent angles between 45° and 90°.
The output height and output distance depends on the type of confetti and the set
angle. The maximum load per blast also depends on the type of confetti. Check the
following table.
TypeofconfettiMax. load per blastOutput height Output distance
Metallic confetti20 kg12 m25 m
Paper confetti10 kg12 m25 m
Snow/Powder confetti5 kg12 m25 m
Confetti types and related loads and output
NOTICE
Wind and other weather circumstances will inuence the output
height and output distance of the confetti. The given values are
estimated values.
MAGICFX® STADIUMBLASTER — User and Installation Manual7
1.6 DMX CONTROL
When connected to DMX the MAGICFX® STADIUMBLASTER is controlled with 1 safety
address and 1 operational address:
DMX AddressAddress range
Safety1 – 512
Start1 – 512
DMX addresses
The safety address cannot be the same as (one of) the operational address(es).
Operating of these addresses results in the following:
DMX AddressDMXValue(decimal)Result
099Device disabled
Safety
Start (output)
When you link multiple machines with DMX, we advise you to use the same Safety
address for all machines.
100155Device enabled
156255Device disabled
0199Valve closed
200255Valve open
Operation of the DMX addresses
CAUTION
Always plug in a DMX Terminator into the DMX output of the nal
unit in the control sequence. Using a DMX Terminator improves
signal reliability.
1.7DISPLAY PANEL
MAIN MENU
DMX/RDM SETTINGS
BACKPREV NEXT
8 MAGICFX® STADIUMBLASTER — User and Installation Manual
SELECT
Display panel
The display panel is located on the backside of the MAGICFX® STADIUMBLASTER.
Check the following menu structure for all options in the menu. Use the buttons for
navigation and selection. The le-hand LED blinks red when DMX is active. The right-
hand LED continuously lights red when an error is present.
DMX Start Address (1 – 512)
Lock/Unlock Controller
(press and hold for 5 seconds)
Idle Display
DMX Safety Address (1 – 512)
Reset Errors
DMX Footprint (Fixed)
DMX/RDM Settings
RDM (ON/OFF)
Display Dimmer (ON/OFF)
(dims aer 30 seconds of button inactivity)
Configuration
Main Menu
Factory Defaults (YES/NO)
Error History
Type (Alarm/Error)
Serial Number
Information
Unique ID
Soware Version
Soware CRC
Bootloader CRC
Build Date
Uptime (DDDD:HH:MM:SS)
Effect Time (DDDD:HH:MM:SS)
MAGICFX® STADIUMBLASTER — User and Installation Manual 9
Menu structure
1.8 RDM CAPABILITY
Remote Device Management Protocol (RDM) is an enhancement of the DMX512
communication protocol. RDM can be used for conguration and status monitoring
while DMX512 takes care of the default controlling.
For RDM you will need a RDM compatible controller. The following RDM parameters
®
are supported by the MAGICFX
STADIUMBLASTER.
ParameterIDDiscoveryGETSET
DISC_UNIQUE_BRANCHX
DISC_MUTEX
DISC_UN_MUTEX
DEVICE_INFOX
SUPPORTED_PARAMETERSX
SOFTWARE_VERSION_LABELX
DEVICE_MODEL_DESCRIPTIONX
MANUFACTURER_LABELX
SLOT_DESCRIPTIONX
DMX_PERSONALITY_DESCRIPTIONX
SENSOR_DEFINITIONX
SENSOR_VALUEX
DMX_START_ADDRESSXX
IDENTIFY_DEVICEXX
DEVICE_LABELXX
FACTORY_DEFAULTSXX
DMX_PERSONALITYXX
RESET_DEVICEX
RDM parameters
RDM parameters are subject of change due to soware updates. Contact MAGIC FX
for the latest information and updates.
10 MAGICFX® STADIUMBLASTER — User and Installation Manual
2 BLAST SAFELY!
The MAGICFX® STADIUMBLASTER has been designed and constructed in such a
manner that it can be used safely. This applies to the use, the circumstances and the
regulations as described in this documentation. Reading this documentation and
following the instructions are therefore necessary for everyone who is authorised to
work with the MAGICFX
The MAGICFX® STADIUMBLASTER must be used in surroundings that:
• Have a stable temperature of between -20 and 70 °C.
• Have a relative humidity degree between 20 % and 90 % (non condensing).
• Are free of dust, corrosive gases and high concentrations of organic vapours.
• Are not situated in the vicinity of a source of vibration.
2.1 GENERAL SAFETY RULES
• Only authorised persons may carry out work with the MAGICFX®
STADIUMBLASTER.
• Do not use the MAGICFX® STADIUMBLASTER if there are people or animals in
the direct output.
• Make sure that children, unauthorised people and animals do not obtain
access to the MAGICFX® STADIUMBLASTER.
• Make sure there are no freestanding objects or objects that can be damaged
by the MAGICFX® STADIUMBLASTER within the output distance.
• Do not connect more units to a single electrical circuit than the installed fuse
is able to handle. (Calculate the summed load with the electrical data from
Chapter 1)
• Do not remove any safeguards, safety caps and safety symbols.
• All required safety devices must be in good condition and function properly.
• Ensure sucient lighting of the surroundings.
• Keep the workplace clean.
®
STADIUMBLASTER.
2.2 CO2
The MAGICFX® STADIUMBLASTER uses liquid or gaseous CO2 as input. The application
of CO2 involves serious risks. Make sure that you are well informed on these risks
before installation and/or operation. Always use approved CO2 cylinders, hoses and
connections. Always consult your CO2 supplier for regulations and instructions on safe
installation and use.
MAGIC FX is not liable for unsafe situations, accidents and damage that are the result
of incorrect working with CO2 and CO2 cylinders.
MAGICFX® STADIUMBLASTER — User and Installation Manual 11
WARNING
Inadequate installation and/or operation of a CO2 powered
machine and CO2 cylinders can lead to death or serious injury.
Always follow the instructions from this manual, from your CO2
supplier and from local authorities.
2.3 INDOOR USE
The MAGICFX® STADIUMBLASTER is designed for outdoor use and use in well-ventilated
indoor spaces. When used indoors, make sure you take the necessary preparations.
These preparations could include, but are not limited to:
• Consulting your CO2 supplier.
• Calculating the reduction of oxygen for the indoor space.
• Checking the location for spots where CO2 could accumulate and taking
preventive actions.
• Installing CO2 monitoring devices that will warn for hazardous CO2 levels.
DANGER
Do not use the MAGICFX® STADIUMBLASTER in poorly ventilated
conned spaces. Exposure to high levels of CO2 gas can cause
symptoms like headache, nausea, loss of consciousness or even
death.
2.4 RIGGING
Please follow the European and national guidelines for safe rigging and trussing.
2.5 NOISE LEVEL
The environmental noise level as measured at the ear is 97 dB(A). This level of noise is
only reached during the short instances that the CO2 output is active. Therefore
hearing protection is not necessary.
WARNING
Do not operate the MAGICFX® STADIUMBLASTER close to yourself
or to others for a long period of time. If you experience any
hearing loss or ringing in the ears, you should immediately stop
using the unit.
12 MAGICFX® STADIUMBLASTER — User and Installation Manual
2.6 SAFETY SYMBOLS
4
5
˚
SymbolMeaning
Read the manual carefully before use!
2.7PRECAUTIONS FOR OPERATION
Safety symbols
WARNING
WARNING
CAUTION
WARNING
WARNING
Using a damaged or an improper installed machine can lead to
death, serious injury or property damage. Always inspect the
machine thoroughly before operation.
Missing or obscured safety symbols on the machine can lead to
death, serious injury or property damage. Make sure all safety
symbols are correctly in place and visible, see Section 2.6.
A missing or loose-tted woofer can lead to injury. Make sure that
the woofer is correctly in place on the bayonet connection and
secured with the safety steel.
Make sure there are no objects near the output that can be
damaged or overthrown by the MAGICFX® STADIUMBLASTER.
Always create a safety zone around the MAGICFX®
STADIUMBLASTER and its output according to the following picture.
2 m
4 m
MAGICFX® STADIUMBLASTER — User and Installation Manual 13
3 LET’S BLAST!
3.1 INSTALL THE MACHINE
1 Bring the cased MAGICFX® STADIUMBLASTER to the desired location.
2 Unlock and remove the top cover.
14 MAGICFX® STADIUMBLASTER — User and Installation Manual
3 Unlock and remove the cover from the bottom cabinet.
4 Take out the woofer.
MAGICFX® STADIUMBLASTER — User and Installation Manual 15
5 Screw the woofer rmly onto the bayonet socket of the hopper until it locks in
place.
6 Secure the woofer with the safety steel.
16 MAGICFX® STADIUMBLASTER — User and Installation Manual
7Optionally you can set the hopper with the attached woofer in one of the
5 pre-set angles.
8 Place the MAGICFX® STADIUMBLASTER in its nal position and set the brakes.
9 Take the necessary safety precautions, see Section 2.7.
MAGICFX® STADIUMBLASTER — User and Installation Manual17
10Make sure the manual CO2 valve is in CLOSED position.
11 Connect the CO2 hose to the CO2 quick connector.
18 MAGICFX® STADIUMBLASTER — User and Installation Manual
12 Connect a CO₂ Bottle to
Hose Connector to a CO2
cylinder.
13 Connect the CO2 hose to the
CO₂ Bottle to Hose
Connector on the CO2
cylinder.
14 Open the CO2 cylinder.
15 In case of multiple machines: Repeat steps 1 – 14 for each machine.
MAGICFX® STADIUMBLASTER — User and Installation Manual 19
3.2 FILL WITH CONFETTI BEFORE EACH BLAST
1 Unlock and open the lid of the hopper.
2 Fill the hopper with confetti. Check Section 1.5 for the maximum amount per
type of confetti.
20 MAGICFX® STADIUMBLASTER — User and Installation Manual
3 Close and lock the lid of the hopper.
4 In case of multiple machines: Repeat steps 1 – 3 for each machine.
3.3 BLAST MANUALLY
1 Make sure that the safety zone is free from persons and hazardous objects.
2 When it’s time to blast, move the manual CO2 valve in OPEN position.
NOTICE
The best eect results are achieved when you open the lid just
before you start blasting. Make sure that no foreign objects will
enter the hopper and close the lid again aer the eect.
MAGICFX® STADIUMBLASTER — User and Installation Manual 21
3 Enjoy the view!
4 When the hopper is out of confetti, move the manual CO2 valve back in
CLOSED position.
22 MAGICFX® STADIUMBLASTER — User and Installation Manual
3.4 CONNECT 24 V CONTROL
24 V24 V
1. Connect two cables to the 24 V input.
2. Connect the other ends of the cables to your controller.
NOTICE
NOTICE
No additional power source is needed. The controller provides
power to the MAGICFX® STADIUMBLASTER to open and close the
output valve.
The FX LED indicator and the display and buttons are inactive
when control is applied. The controller only powers the output
valve.
3.5 BLAST WITH 24 V CONTROL
1. Make sure that the safety zone is free from persons and hazardous objects.
2. When it’s time to blast, continuously, enable the output on your 24 V controller
and make sure to produce a continuous pulse.
NOTICE
3. Enjoy the view!
4. When the hopper is out of confetti, disable the output on your 24 V controller.
The best eect results are achieved when you open the lid just
before you start blasting. Make sure that no foreign objects will
enter the hopper and close the lid again aer the eect.
MAGICFX® STADIUMBLASTER — User and Installation Manual 23
3.6 CONNECT POWER AND SETUP DMX
POWER INPOWER OUT
DMX
5-pole female
PowerCon TRUE1 female
DMX INDMX OUT
POWER
1. Connect a power cable with a Powercon TRUE1 Female connector to the
power input.
2. Connect the other end of the power cable to a 100 – 250 Vac (50 – 60 Hz)
power source.
3. Connect the female connector of a 5-pole DMX cable in the DMX input.
4. Connect the other end of the DMX cable to your DMX controller.
5. Use the display and buttons or a RDM controller to assign DMX addresses, see
chapter 1.
CAUTION
Always plug in a DMX Terminator into the DMX output. Using a
DMX Terminator improves signal reliability.
24 MAGICFX® STADIUMBLASTER — User and Installation Manual
3.7SETUP MULTIPLE MACHINES IN A SEQUENCE WITH DMX
5-pole male
5-pole female
DMX
DMX INDMX OUT
POWER INPOWER OUT
PowerCon TRUE1 male
POWER
PowerCon TRUE1 female
1. Connect a power link cable to the power output.
2. Connect the other end to the power input of the next machine.
3. Connect a DMX cable to the DMX output.
4. Connect the other end to the DMX input of the next machine.
5. Use the buttons or a RDM controller to assign DMX addresses, see chapter 1.
6. Repeat step 1 to 5 for each subsequent machine.
CAUTION
Always plug in a DMX Terminator into the DMX output of the nal
unit in the control sequence. Using a DMX Terminator improves
signal reliability.
3.8 BLAST WITH DMX
1. Make sure that each safety zone is free from persons and hazardous objects.
2. Activate the Safety address. The FX LED indicator on each machine lights up.
3. When it’s time to blast, activate the Start address.
NOTICE
The best eect results are achieved when you open the lid just
before you start blasting. Make sure that no foreign objects will
enter the hopper and close the lid again aer the eect.
DMX INDMX OUT
POWER INPOWER OUT
4. Enjoy the view!
5. Deactivate the Start address when the hopper is out of confetti.
MAGICFX® STADIUMBLASTER — User and Installation Manual 25
3.9 REPLACE A CO2 CYLINDER
1 Make sure that:
a) The manual CO
in CLOSED position.
valve is
2
b) The DMX Safety address
is not activated (FX LED
indicator is dimmed).
c) The 24 V controller (if
used) is not powered.
2 Close the CO2 cylinder.
3 Move the manual CO2 valve
in OPEN position to release
the pressure from the system.
4 Move the manual CO2 valve
back in CLOSED position.
26 MAGICFX® STADIUMBLASTER — User and Installation Manual
5 Disconnect the CO2 hose from the
CO2 Bottle to Hose Connector on
the CO2 cylinder.
6 Remove the CO2 Bottle to Hose
Connector from the cylinder.
7Connect a CO2 Bottle to Hose
Connector to a new CO2 cylinder.
MAGICFX® STADIUMBLASTER — User and Installation Manual27
8 Connect the CO2 hose to the CO2
Bottle to Hose Connector on the
new CO2 cylinder.
9 Open the CO2 cylinder.
10 In case of multiple machines: Repeat steps 1 – 9 for each machine.
3.10CLEAN UP
1 Deactivate the Safety address
(FX LED indicator on each machine
dims).
2 Disconnect any 24 V, DMX and
power cable(s).
3 Close the CO
28 MAGICFX® STADIUMBLASTER — User and Installation Manual
cylinder.
2
4 Move the manual CO2 valve
in OPEN position to release
the pressure from the system.
5 Disconnect the CO2 hose
from the CO2 quick
connector.
6 Disconnect the CO2 hose from the
CO2 Bottle to Hose Connector on
the CO2 cylinder.
MAGICFX® STADIUMBLASTER — User and Installation Manual 29
7Remove the CO2 Bottle to Hose
Connector from the cylinder.
8 Wait until the ice crust on the output has melted.
9 In case you have set the hopper under an angle: Position the hopper back in
horizontal position (position 1).
30 MAGICFX® STADIUMBLASTER — User and Installation Manual
10 Remove the safety steel.
11 Remove the woofer.
MAGICFX® STADIUMBLASTER — User and Installation Manual 31
12 Remove the woofer.
13 Place and lock the cover of
the bottom cabinet.
14 Unlock and open the lid
from the hopper.
32 MAGICFX® STADIUMBLASTER — User and Installation Manual
15 Remove remaining confetti
from the hopper.
16 Close and lock the lid from
the hopper.
17 Place and lock the top
cover.
18 Release the brakes.
MAGICFX® STADIUMBLASTER — User and Installation Manual 33
4 MAINTENANCE
To achieve the maximum service life of the MAGICFX® STADIUMBLASTER you must
regularly clean the MAGICFX
Contact MAGIC FX if the MAGICFX® STADIUMBLASTER is not functioning correctly.
DANGER
®
STADIUMBLASTER and test if it is functioning correctly.
Do not replace parts yourself; always consult MAGIC FX.
5 TROUBLESHOOTING
Always contact MAGIC FX if any malfunctions or errors occur that cannot be solved
with the instructions as described in this manual.
6 CORRECT DISPOSAL
This symbol on the product and / or accompanying documents
means that used electrical and electronic products should not be
mixed with general household waste. For proper treatment,
recovery and recycling, please take this product to designated
collection points where it will be accepted free of charge.
Alternatively, in some countries you may be able to return your
products to your local retailer upon purchase of an equivalent new
product.
Disposing of this product correctly will help save valuable resources and prevent any
potential negative eects on human health and the environment, which could
otherwise arise from inappropriate waste handling.
Please contact your local authority for further details of your nearest designated
collection point.
Penalties may be applicable for incorrect disposal of this waste, in accordance with
your national legislation.
34 MAGICFX® STADIUMBLASTER — User and Installation Manual
7EC DECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY
According to Annex III A Low Voltage Directive 2014/35/EU + Machinery Directive
2006/42/EC
MAGIC FX B.V. declares as manufacturer and composer of the technical construction file that the
product with the following specifications:
Name machine: STADIUMBLASTER
Type: MFX0803
Voltage: 100-250Vac 50-60Hz
Serial number: on product
Year of construction: on product
Is in conformity with the minimal safety regulations as stated in the following directive(s):
• EMC (2014/30/EC) ElectroMagnetic Compatibility
• RoHS (2011/65/EU) Restriction of the use of certain Hazardous Substances
• NEN-EN-ISO 12100:2010 Safety of machinery - General principles for design - Risk
assessment and risk reduction.
• NEN-EN-IEC 60204-1:2006, Safety of machinery - Electrical equipment of machines - Part 1:
General requirements.
• NEN-EN-IEC 61000-6-3:2007/A1:2011, Electromagnetic compatibility (EMC) - Part 6-3:
Generic standards - Emission standard for residential, commercial and light-industrial
environments.
Original declaration of conformity
Translation of the original declaration of conformity
Name manufacturer: MAGIC FX BV
Address: Schouwrooij 27, 5281 RE BOXTEL
Country: The Netherlands
CEO: B. Veroude
Date: 17-01-2017
Signature:
MAGICFX® STADIUMBLASTER — User and Installation Manual 35
WWW.MAGICFX.EU
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.