12 MAGICFX® PSYCO2JET — User and Installation Manual
In PRESET mode the MAGICFX® PSYCO2JET is controlled with 1 safety address and 4 operational
addresses.
DMX Address Address range
Safety address 1 - 512
Start address (Preset) 1 - 512
Start address + 1 (Speed) 1 - 512
Start address + 2 (Direction) 1 - 512
Start address + 3 (Go) 1 - 512
DMX addresses
The Safety address cannot be the same as one of the operational addresses. Operating of the
addresses in PRESET mode results in the following:
DMX Address DMX Value
(Decimal)
Function
Safety address
0 99 Device disabled
100 155 Device enabled
156 255 Device test mode (CO2 output is disabled)
Start address (Preset)
0 24 #1: Single pulse straight up (0°)
25 49 #2: 2 pulses distributed over 180° (-45° +45°)
50 74 #3: 3 pulses distributed over 180° (-90°, 0°, +90°)
75 99 #4: 4 pulses distributed over 180° (-90°, -30°, +30°, +90°)
100 124
#5: 5 pulses distributed over 180° (-90°, -45°, 0°, +45°,
+90°)
125 149 #6: Random pulses over 180°
150 174
#7: Pulse at +45°, pulse at -45°, pulse at +45°, sweep
from -45° back to +45°
175 199
#8: Three sweeps over 180° (-90° to -54°, -18° to +18°
and +54° to +90°)
200 224
#9: Pulse at -90°, pulse at +90°, pulse at -60°, pulse at
+60°, pulse at -30°, pulse at +30°, long pulse at 0°
225 255 #10: Sweep over 180°
Start address + 1 (Speed)
0 255 Minimal speed -> Full speed
Start address + 2 (Direction)
0 63 Le Preset repeatedly starts from the le
64 127 Le Bounce
Preset repeatedly starts from the le
and returns mirrored from the right
128 191 Right Bounce
Preset repeatedly starts mirrored from
the right and returns from the le
192 255 Right Preset repeatedly starts from the right
Start address + 3 (Go)
0 199 O
200 249 Continuous mode
250 255 Step in preset
Operation of the DMX addresses