MAGIC FX MFX0803 User And Installation Manual

STADIUM
BLASTER.
®
CONFETTI & STREAMER FX
PART 01104
rev 01-00
USER AND INSTALLATION MANUAL
2 MAGICFX® STADIUMBLASTER — User and Installation Manual
DISCLAIMER
WARNING
Read this manual carefully before installing and/or using this product. Failure to read the manual and to follow the printed instructions may lead to personal injury and/or damage to the product.
© 2017 MAGICFX
®
All rights reserved.
Nothing from this publication may be copied, reproduced and/or published by means of printing, photocopying or by any other means, without the prior written approval of MAGIC FX.
MAGIC FX reserves the right to modify specications stated in this manual.
TRADEMARKS
Any brand names mentioned in this manual are registered trademarks of their respective owners.
LIABILITY
MAGIC FX accepts no liability for claims from third parties arising from unauthorised use, use other than that stated in this manual, and use other than in accordance with the General Conditions registered at the Chamber of Commerce.
Refer further to the General Conditions. These are available on request, free of charge.
Although considerable care has been taken to ensure a correct and suitably comprehensive description of all relevant components, the manual may nonetheless contain errors and inaccuracies.
Should you detect any errors or inaccuracies in the manual, we would be grateful if you would inform us. This helps us to further improve our documentation.
MAGICFX® STADIUMBLASTER — User and Installation Manual 3
TABLE OF CONTENTS
Disclaimer 2 Trademarks 2 Liability 2 Foreword 4 Language 4 Revision table 4
1 Meet the MAGICFX® STADIUMBLASTER! 5
1.1 Main parts 5
1.2 Technical data 6
1.3 Productidentication 6
1.4 Accessories 7
1.5 Confetti 7
1.6 DMX control 8
1.7 Display panel 9
1.8 RDM capability 10
2 Blast safely! 11
2.1 General safety rules 11
2.2 CO2 11
2.3 Indoor use 11
2.4 Rigging 12
2.5 Noise level 12
2.6 Safety symbols 12
2.7 Precautions for operation 12
3 Let’s blast! 13
3.1 Install the machine 13
3.2 Fill with confetti before each blast 18
3.3 Blast manually 19
3.4 Connect 24 V control 20
3.5 Blast with 24 V control 21
3.6 Connect power and setup DMX 21
3.7 Setup multiple machines in a sequence with DMX 22
3.8 Blast with DMX 22
3.9 Replace a CO2 cylinder 23
3.10 Clean up 25
4 Maintenance 31
5 Troubleshooting 31
6 Correct disposal 31
7 EC Declaration of Conformity 32
4 MAGICFX® STADIUMBLASTER — User and Installation Manual
LANGUAGE
This document contains the original instructions in English. In case you require other languages please contact MAGIX FX.
REVISION TABLE
Document nr Revision Date Description Authored by Checked by
PART01104 01-00 13-02-2017 Initial release TFR TVA
FOREWORD
Congratulations! You have bought a great new product from MAGIC FX.
This manual contains all information required for the intended use of the equipment. Deviation from the described intended use can result in a hazardous situation and/or property damage.
This manual includes notes and warnings on safe operation of the equipment. These notes and warnings are accompanied by the following icons. Read them attentively!
DANGER
Indicates a hazardous situation that, if not avoided, will result in death or serious injury. This signal word is to be limited to the most extreme situations.
WARNING
Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates information considered important, but not hazard-related (e.g. messages relating to property damage).
MAGICFX® STADIUMBLASTER — User and Installation Manual 5
1 MEET THE MAGICFX® STADIUMBLASTER!
The MAGICFX® STADIUMBLASTER is a special eects machine that launches confetti into the air up to a height of 12 meters.
The MAGICFX® STADIUMBLASTER is equipped with a CO2 powered woofer. CO2 is shot into the
woofer through small holes. This creates a Venturi eect that draws the confetti continuously from
the hopper, out of the woofer and into the air. The shot is accompanied by a strong hissing sound. If liquid CO2 is applied, a white plume of smoke will be visible.
The MAGICFX® STADIUMBLASTER is outtted for operation:
• by hand with the manual CO2 valve;
• with a 24 V controller;
• with DMX and optionally RDM.
With DMX you can operate multiple machines in a sequence.
1.1 MAIN PARTS
WOOFER
HOPPER
FX LED INDICATOR
MANUAL CO
2
VALVE
DISPLAY WITH BUTTONS AND LED INDICATORS
BOTTOM CABINET
CO
2
INPUT
FLIGHTCASE
24V INPUT
DMX INPUT & OUTPUT
(5-POLE)
POWER INPUT & OUTPUT
(100-250VAC)
Main parts in backside view
6 MAGICFX® STADIUMBLASTER — User and Installation Manual
1.2 TECHNICAL DATA
Product Product Name MAGICFX® STADIUMBLASTER
Product Code MFX0803
Product Type CONFETTI & STREAMER FX
Main Dimensions
Length (mm/in) 800 31,5
Width (mm/in) 600 23,6
Height (mm/in) 1100 43,3
Weight Weight (kg/lb) 84,3 185,8
Environment Minimum Temperature (ºC/ºF) -20 -4
Maximum Temperature (ºC/ºF) 70 158
Humidity (Relative) 20% to 90% (non condensing)
IEC 60529 (IP) Rating
IP13
Electrical Voltage Input (Vac) 100-250Vac
Voltage Frequency 50-60Hz
Power Consumption (Vac) 20W
Power Connector (Vac) Neutrik
®
powerCON TRUE1 (in & out)
Voltage Input (Vdc) 18-36Vdc
Power Consumption (Vdc) 17W
Power Connector (Vdc) Banana Plug & Wire
Controlling Control Options DMX / Manual valve / 24 Vdc
Control Protocols DMX512-A (ANSI E1.11) / RDM (ANSI E1.20)
Control Connectors Neutrik
®
5 pole male / female XLR
Conguring Congure Options On Device & RDM
Usage Consumable(s) MagicFX
®
Confetti
Consumable Consumption depends on type of confetti, see Section 1.5
Propellant Liquid or Gaseous CO
2
Propellant Connector CO2 Quick Connector 3/8”
Propellant Consumption
0,5L/s
Technical data
1.3 PRODUCT IDENTIFICATION
Type plate
MAGICFX® STADIUMBLASTER — User and Installation Manual 7
1.4 ACCESSORIES
Code Product
MFX1114 CO₂ High Pressure Hose 3/8 Male - Female, 1.25M
MFX1105 CO₂ High Pressure Hose 3/8 Male - Female, 2M
MFX1106 CO₂ High Pressure Hose 3/8 Male - Female, 3M
MFX1107 CO₂ High Pressure Hose 3/8 Male - Female, 6M
MFX1108 CO₂ High Pressure Hose 3/8 Male - Female, 10M
MFX1109 CO₂ High Pressure Hose 3/8 Male - Female, 15M
MFX1110 CO₂ 90 Degrees Connector 3/8
MFX1103 CO₂ Bottle to Hose Connector
MFX1115 CO₂ Bottle to Hose Connector 90 Degrees
Accessories
Please contact MAGIC FX for additional possibilities.
1.5 CONFETTI
The MAGICFX® STADIUMBLASTER can be set in 5 dierent angles between 45° and 90°. The output height and output distance depends on the type of confetti and the set angle. The maximum load per blast also depends on the type of confetti. Check the following table.
Type of confetti Max. load per blast Output height Output distance
Metallic confetti 20 kg 12M 25M
Paper confetti 10 kg 12M 25M
Snow or Powder confetti 5 kg 12M 25M
Confetti types and related loads and output
NOTICE
Wind and other weather circumstances will inuence the output height and
output distance of the confetti. The given values are estimated values.
8 MAGICFX® STADIUMBLASTER — User and Installation Manual
1.6 DMX CONTROL
When connected to DMX the MAGICFX® STADIUMBLASTER is controlled with 1 safety address and 1
operational address:
DMX Address Address range
Safety 1 - 512
Start 1 - 512
DMX addresses
The Safety address cannot be the same as (one of) the operational address(es). Operating of
these addresses results in the following:
DMX Address DMX Value (decimal) Result
Safety
0 99 Device disabled
100 155 Device enabled
156 255 Device disabled
Start (output)
0 199 Valve closed
200 255 Valve open
Operation of the DMX addresses
When you link multiple machines with DMX, we advise you to use the same Safety address for all machines.
CAUTION
Always plug in a DMX Terminator into the DMX output of the nal unit in the
control sequence. Using a DMX Terminator improves signal reliability.
MAGICFX® STADIUMBLASTER — User and Installation Manual 9
1.7 DISPLAY PANEL
MAIN MENU
DMX/RDM SETTINGS
BACK PREV NEXT
SELECT
Display panel
The display panel is located on the backside of the MAGICFX® STADIUMBLASTER. Check the following menu structure for all options in the menu. Use the buttons for navigation and selection.
The le-hand LED blinks red when DMX is active. The right-hand LED blinks red when an error has
occurred.
Idle Display
Main Menu
DMX Start Address (1-512)
DMX Safety Address (1-512)
DMX Footprint (Fixed)
RDM (On/O)
Display Dimmer (On/O)
Factory Defaults (Yes/No)
Unique ID
Soware Version
Soware CRC
Bootloader CRC
Build Date
Lock/Unlock Controller
Reset Errors
DMX/RDM Settings
Conguration
Error History
Information
Menu structure
10 MAGICFX® STADIUMBLASTER — User and Installation Manual
1.8 RDM CAPABILITY
Remote Device Management Protocol (RDM) is an enhancement of the DMX512 communication
protocol. RDM can be used for conguration and status monitoring while DMX512 takes care of
the default controlling.
For RDM you will need a RDM compatible controller, cables and a RDM responder like the MAGICFX® STADIUMBLASTER.
The following RDM parameters are supported by the MAGICFX® STADIUMBLASTER.
Parameter ID Discovery GET SET
DISC_UNIQUE_BRANCH X
DISC_MUTE X
DISC_UN_MUTE X
DEVICE_INFO X
SUPPORTED_PARAMETERS X
SOFTWARE_VERSION_LABEL X
DEVICE_MODEL_DESCRIPTION X
MANUFACTURER_LABEL X
DMX_START_ADDRESS X X
IDENTIFY_DEVICE X X
DEVICE_LABEL X X
FACTORY_DEFAULTS X X
SLOT_DESCRIPTION X
RESET_DEVICE X
RDM parameters
RDM parameters are subject of change due to soware updates. Contact MAGIC FX for the latest
information and updates.
MAGICFX® STADIUMBLASTER — User and Installation Manual 11
2 BLAST SAFELY!
The MAGICFX® STADIUMBLASTER has been designed and constructed in such a manner that it can be used safely. This applies to the use, the circumstances and the regulations as described in this documentation. Reading this documentation and following the instructions are therefore necessary for everyone who is authorised to work with the MAGICFX® STADIUMBLASTER.
The MAGICFX® STADIUMBLASTER must be placed and used in surroundings that preferably:
Have a reasonably stable temperature of between -20 and 70°C.
• Have a relative humidity degree of no more than 90% (non condensing).
• Are reasonably free of dust, corrosive gases and high concentrations of organic vapours.
• Are not situated in the vicinity of a source of vibration.
2.1 GENERAL SAFETY RULES
• Only authorised persons may carry out work with the MAGICFX® STADIUMBLASTER.
• Do not use the MAGICFX® STADIUMBLASTER if there are people or animals in the direct output.
• Make sure that children, unauthorised people and animals do not obtain access to the MAGICFX® STADIUMBLASTER.
• Make sure there are no freestanding objects or objects that can be damaged by the MAGICFX® STADIUMBLASTER within the output distance.
• Do not connect more units to a single electrical circuit than the installed fuse is able to handle. (Calculate the summed load with the electrical data from Section 1.2)
• Do not remove any safeguards, safety caps and safety symbols.
• All required safety devices must be in good condition and function properly.
Ensure sucient lighting of the surroundings.
• Keep the workplace clean.
2.2 CO2
The MAGICFX® STADIUMBLASTER uses CO2 gas or liquid CO2 as input. The application of CO2 involves serious risks. Make sure that you are well informed on these risks before installation and/or operation. Always use approved CO2 cylinders, hoses and connections. Always consult your CO2 supplier for regulations and instructions on safe installation and use.
MAGIC FX is not liable for unsafe situations, accidents and damage that are the result of incorrect working with CO2 gas and CO2 cylinders.
WARNING
Inadequate installation and/or operation of a CO2 powered machine and CO2 cylinders can lead to death or serious injury. Always follow the instructions from this manual, from your CO2 supplier and from local authorities.
2.3 INDOOR USE
The MAGICFX® STADIUMBLASTER is designed for outdoor use and use in well-ventilated indoor spaces. When used indoors, make sure you take the necessary preparations. These preparations
could include, but are not limited to:
• Consulting your CO2 supplier.
• Calculating the reduction of oxygen for the indoor space.
12 MAGICFX® STADIUMBLASTER User and Installation Manual
• Checking the location for spots where CO2 could accumulate and taking preventive actions.
• Installing CO2 monitoring devices that will warn for hazardous CO2 levels.
DANGER
Do not use the MAGICFX® STADIUMBLASTER in poor ventilated conned spaces. Exposure to high levels of CO2 gas can cause symptoms like headache, nausea, loss of consciousness or even death.
2.4 RIGGING
Please follow the European and national guidelines for safe rigging and trussing.
2.5 NOISE LEVEL
The environmental noise level as measured at the ear is 97 dB(A). This level of noise is only reached during the short instances that the CO2 output is active. Therefore hearing protection is not necessary.
WARNING
Do not operate the MAGICFX® STADIUMBLASTER close to yourself or to others for a long period of time. If you experience any hearing loss or ringing in the ears, you should immediately stop using the unit.
2.6 SAFETY SYMBOLS
The following safety symbols are present on the MAGICFX® STADIUMBLASTER.
Symbol Meaning
Read the manual carefully before use!
Safety symbols
2.7 PRECAUTIONS FOR OPERATION
WARNING
Using a damaged or an improper installed machine can lead to death, serious injury or property damage. Always inspect the machine thoroughly before operation.
WARNING
Missing or obscured safety symbols on the machine can lead to death, serious injury or property damage. Make sure all safety symbols are correctly in place and visible, see Section 2.6.
CAUTION
A missing or loose-tted woofer can lead to injury. Make sure that the woofer is
correctly in place on the bayonet connection and secured with the safety steel.
MAGICFX® STADIUMBLASTER — User and Installation Manual 13
3 LET’S BLAST!
3.1 INSTALL THE MACHINE
1 Bring the cased MAGICFX®
STADIUMBLASTER to the desired location.
2 Unlock and remove the top cover.
14 MAGICFX® STADIUMBLASTER — User and Installation Manual
3 Unlock and remove the cover from the
bottom cabinet.
4 Take out the woofer.
5 Screw the woofer rmly onto the bayonet socket of the hopper until it locks in place.
MAGICFX® STADIUMBLASTER — User and Installation Manual 15
6 Secure the woofer with the safety steel.
7 Optionally you can set the hopper with
the attached woofer in one of the 5 pre-set angles.
16 MAGICFX® STADIUMBLASTER — User and Installation Manual
8 1. Create a safety zone of 2 m around
the MAGICFX® STADIUMBLASTER.
2. Make sure that the direct output will be free from persons and animals.
3. Make sure there are no freestanding objects or objects that can be damaged by the MAGICFX
®
STADIUMBLASTER within the output distance.
4
5
˚
2 m
4 m
9 Place the MAGICFX® STADIUMBLASTER in
its nal position and set the brakes.
10 Make sure the manual CO2 valve is in
CLOSED position.
MAGICFX® STADIUMBLASTER — User and Installation Manual 17
11 Connect the CO2 hose to the CO2 quick
connector.
12 Connect a CO₂ bottle-to-hose connector
to a CO2 cylinder.
13 Connect the CO2 hose to the CO₂ bottle-
to-hose connector on the CO2 cylinder.
18 MAGICFX® STADIUMBLASTER — User and Installation Manual
14 Open the CO2 cylinder.
15 In case of multiple machines: Repeat steps 1-14 for each machine.
3.2 FILL WITH CONFETTI BEFORE EACH BLAST
1 Unlock and open the lid of the hopper.
2 Fill the hopper with confetti. Check Section 1.5 for the maximum amount per type of confetti.
MAGICFX® STADIUMBLASTER — User and Installation Manual 19
3 Close and lock the lid of the hopper.
4 In case of multiple machines: Repeat steps 1-3 for each machine.
3.3 BLAST MANUALLY
1 2Make sure that the prescribed safety
zone is free from persons and objects.
When it’s time to blast, move the manual CO
2
valve in OPEN position.
3 Enjoy the view!
20 MAGICFX® STADIUMBLASTER — User and Installation Manual
4 When the hopper is out of confetti, move
the manual CO2 valve back in CLOSED position.
3.4 CONNECT 24 V CONTROL
24V 24V
1. Connect two cables to the 24 V input.
2. Connect the other ends of the cables to your controller.
NOTICE
No additional power source is needed. The controller provides power to the MAGICFX® STADIUMBLASTER to open and close the output valve.
NOTICE
The FX LED indicator and the display and buttons are inactive when control is applied. The controller only powers the output valve.
MAGICFX® STADIUMBLASTER — User and Installation Manual 21
3.5 BLAST WITH 24 V CONTROL
1. Make sure that the prescribed safety zone is free from persons and objects.
2. When it’s time to blast, continuously, enable the output on your 24 V controller and make
sure to produce a continuous pulse.
3. Enjoy the view!
4. When the hopper is out of confetti, disable the output on your 24 V controller..
3.6 CONNECT POWER AND SETUP DMX
PowerCon TRUE1 female
POWER
5-pole female
DMX
1. Connect a power cable with a Powercon TRUE1 Female connector to the power input.
2. Connect the other end of the power cable to a 100-250 Vac (50-60Hz) power source.
3. Connect the female connector of a 5-pole DMX cable in the DMX input.
4. Connect the other end of the DMX cable to your DMX controller.
5. Use the display and buttons or a RDM controller to assign DMX addresses, see chapter 1.
CAUTION
Always plug in a DMX Terminator into the DMX output. Using a DMX Terminator improves signal reliability.
22 MAGICFX® STADIUMBLASTER — User and Installation Manual
3.7 SETUP MULTIPLE MACHINES IN A SEQUENCE WITH DMX
PowerCon TRUE1 female
5-pole female
PowerCon TRUE1 male
5-pole male
POWER
DMX
1. Connect a power link cable to the power output.
2. Connect the other end to the power input of the next machine.
3. Connect a DMX cable to the DMX output.
4. Connect the other end to the DMX input of the next machine.
5. Use the buttons or a RDM controller to assign DMX addresses, see chapter 1.
6. Repeat step 1 to 5 for each subsequent machine.
CAUTION
Always plug in a DMX Terminator into the DMX output of the nal unit in the
control sequence. Using a DMX Terminator improves signal reliability.
3.8 BLAST WITH DMX
1. Make sure that each prescribed safety zone is free from persons and objects.
2. Activate the Safety address. The FX LED indicator on each machine lights up.
3. When it’s time to blast, activate the Start address.
4. Enjoy the view!
5. Deactivate the Start address when the hopper is out of confetti,
MAGICFX® STADIUMBLASTER — User and Installation Manual 23
3.9 REPLACE A CO2 CYLINDER
1 Make sure that:
the manual CO
2
valve is in CLOSED
position.
the DMX Safety address is not activated (FX LED indicator is dimmed).
the 24 V controller (if used) is not powered.
2 Close the connected CO2 cylinder.
3 Move the manual CO2 valve in OPEN
position to release the pressure from the system.
4 Move the manual CO2 valve back in
CLOSED position.
24 MAGICFX® STADIUMBLASTER — User and Installation Manual
5 Disconnect the CO2 hose from the CO₂
bottle-to-hose connector on the CO2 cylinder.
6 Remove the CO₂ bottle-to-hose
connector from the cylinder.
7 Connect a CO₂ bottle-to-hose connector
to a new CO2 cylinder.
MAGICFX® STADIUMBLASTER — User and Installation Manual 25
8 Connect the CO2 hose to the CO₂ bottle-
to-hose connector on the new CO2 cylinder.
9 Open the CO2 cylinder.
10 In case of multiple machines, connected in series: Repeat step 1-9 for each machine.
3.10 CLEAN UP
1
2 3
Deactivate the Safety address (FX LED indicator on each machine dims). Disconnect any 24 V, DMX and power cable(s). Close the CO2 cylinder.
26 MAGICFX® STADIUMBLASTER — User and Installation Manual
4 Move the manual CO2 valve in OPEN
position to release the pressure from the system.
5 Disconnect the CO2 hose from the CO2
quick connector.
6 Disconnect the CO2 hose from the CO₂
bottle-to-hose connector on the CO2 cylinder.
MAGICFX® STADIUMBLASTER — User and Installation Manual 27
7 Remove the CO₂ bottle-to-hose
connector from the cylinder.
8 Wait until the ice crust on the output has melted.
9 In case you have set the hopper under an angle: Position the hopper back in horizontal
position (position 1).
28 MAGICFX® STADIUMBLASTER — User and Installation Manual
10 Remove the safety steel.
11 Remove the woofer.
12 Store the woofer in the cabinet.
MAGICFX® STADIUMBLASTER — User and Installation Manual 29
13 Place and lock the cover of the bottom
cabinet.
14 Unlock and open the lid from the hopper.
15 Remove remaining confetti from the
hopper.
30 MAGICFX® STADIUMBLASTER — User and Installation Manual
16 Close and lock the lid from the hopper.
17 Place and lock the top cover.
18 Release the brakes.
MAGICFX® STADIUMBLASTER — User and Installation Manual 31
4 MAINTENANCE
To achieve the maximum service life of the MAGICFX® STADIUMBLASTER you must regularly clean the MAGICFX® STADIUMBLASTER and test if it is functioning correctly.
Contact MAGIC FX if the MAGICFX® STADIUMBLASTER is not functioning correctly.
DANGER
Do not replace parts yourself; always consult MAGIC FX.
5 TROUBLESHOOTING
Always contact MAGIC FX if any malfunctions or errors occur that cannot be solved with the instructions as described in this manual.
6 CORRECT DISPOSAL
This symbol on the product and / or accompanying documents means that used electrical and electronic products (WEEE) should not be mixed with general household waste. For proper treatment, recovery and recycling, please take this product to designated collection points where it will be accepted free of charge.
Alternatively, in some countries you may be able to return your products to your local retailer upon purchase of an equivalent new product.
Disposing of this product correctly will help save valuable resources and
prevent any potential negative eects on human health and the environment, which could
otherwise arise from inappropriate waste handling.
Please contact your local authority for further details of your nearest designated collection point.
Penalties may be applicable for incorrect disposal of this waste, in accordance with your national legislation.
32 MAGICFX® STADIUMBLASTER — User and Installation Manual
7 EC DECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY
According to Annex III A Low Voltage Directive 2014/35/EU + Machinery Directive 2006/42/EC
MAGIC FX B.V. declares as manufacturer and composer of the technical construction file that the product with the following specifications:
Name machine : STADIUMBLASTER Type : MFX0803 Voltage : 100-250Vac 50-60Hz Serial number : on product Year of construction : on product
Is in conformity with the minimal safety regulations as stated in the following directive(s):
EMC (2014/30/EC) ElectroMagnetic Compatibility
RoHS (2011/65/EU) Restriction of the use of certain Hazardous Substances
WEEE (2012/19/EU) Waste Electrical & Electronic Equipment
The following harmonized standards were applied:
NEN-EN-ISO 12100:2010 Safety of machinery - General principles for design - Risk a
ssessment and risk reduction.
NEN-EN-IEC 60204-1:2006, Safety of machinery - Electrical equipment of machines - Part 1
:
G
eneral requirements.
NEN-EN-IEC 61000-6-3:2007/A1:2011, Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments.
Original declaration of conformityTranslation of the original declaration of conformity
Name manufacturer : MAGIC FX BV Address : Schouwrooij 27, 5281 RE BOXTEL Country : The Netherlands
CEO : B. Veroude Date : 17-01-2017
Signature :