Read this manual carefully before installing and/or using this product. Failure to
read the manual and to follow the printed instructions may lead to personal
injury and/or damage to the product.
Nothing from this publication may be copied, reproduced and/or published by means of printing,
photocopying or by any other means, without the prior written approval of MAGIC FX.
MAGIC FX reserves the right to modify specications stated in this manual.
TRADEMARKS
Any brand names mentioned in this manual are registered trademarks of their respective owners.
LIABILITY
MAGIC FX accepts no liability for claims from third parties arising from unauthorised use, use other
than that stated in this manual, and use other than in accordance with the General Conditions
registered at the Chamber of Commerce.
Refer further to the General Conditions. These are available on request, free of charge.
Although considerable care has been taken to ensure a correct and suitably comprehensive
description of all relevant components, the manual may nonetheless contain errors and
inaccuracies.
Should you detect any errors or inaccuracies in the manual, we would be grateful if you would
inform us. This helps us to further improve our documentation.
2 MAGICFX® STADIUMBLASTER — User and Installation Manual
3.7 Setup multiple machines in a sequence with DMX 22
3.8 Blast with DMX 22
3.9 Replace a CO2 cylinder 23
3.10 Clean up 25
4 Maintenance 31
5 Troubleshooting 31
6 Correct disposal 31
7 EC Declaration of Conformity 32
MAGICFX® STADIUMBLASTER — User and Installation Manual 3
FOREWORD
Congratulations! You have bought a great new product from MAGIC FX.
This manual contains all information required for the intended use of the equipment. Deviation
from the described intended use can result in a hazardous situation and/or property damage.
This manual includes notes and warnings on safe operation of the equipment. These notes and
warnings are accompanied by the following icons. Read them attentively!
DANGER
WARNING
CAUTION
NOTICE
Indicates a hazardous situation that, if not avoided, will result in death or serious
injury. This signal word is to be limited to the most extreme situations.
Indicates a hazardous situation that, if not avoided, could result in death or
serious injury.
Indicates a hazardous situation that, if not avoided, could result in minor or
moderate injury.
Indicates information considered important, but not hazard-related
(e.g. messages relating to property damage).
LANGUAGE
This document contains the original instructions in English. In case you require other languages
please contact MAGIX FX.
REVISION TABLE
Document nrRevisionDateDescription Authored byChecked by
PART0110401-0013-02-2017Initial releaseTFR TVA
4 MAGICFX® STADIUMBLASTER — User and Installation Manual
1 MEET THE MAGICFX® STADIUMBLASTER!
The MAGICFX® STADIUMBLASTER is a special eects machine that launches confetti into the air up
to a height of 12 meters.
The MAGICFX® STADIUMBLASTER is equipped with a CO2 powered woofer. CO2 is shot into the
woofer through small holes. This creates a Venturi eect that draws the confetti continuously from
the hopper, out of the woofer and into the air. The shot is accompanied by a strong hissing sound.
If liquid CO2 is applied, a white plume of smoke will be visible.
The MAGICFX® STADIUMBLASTER is outtted for operation:
• by hand with the manual CO2 valve;
• with a 24 V controller;
• with DMX and optionally RDM.
With DMX you can operate multiple machines in a sequence.
1.1 MAIN PARTS
FLIGHTCASE
CO
INPUT
2
DMX INPUT & OUTPUT
(5-POLE)
POWER INPUT & OUTPUT
(100-250VAC)
WOOFER
HOPPER
MANUAL CO
VALVE
2
FX LED INDICATOR
DISPLAY WITH BUTTONS
AND LED INDICATORS
BOTTOM CABINET
24V INPUT
Main parts in backside view
MAGICFX® STADIUMBLASTER — User and Installation Manual 5
Control ProtocolsDMX512-A (ANSI E1.11) / RDM (ANSI E1.20)
®
Control ConnectorsNeutrik
5 pole male / female XLR
ConguringCongure OptionsOn Device & RDM
®
UsageConsumable(s)MagicFX
Confetti
Consumable Consumptiondepends on type of confetti, see Section 1.5
PropellantLiquid or Gaseous CO
Propellant ConnectorCO2 Quick Connector 3/8”
Propellant Consumption
0,5L/s
1.3 PRODUCT IDENTIFICATION
2
Technical data
6 MAGICFX® STADIUMBLASTER — User and Installation Manual
Type plate
1.4 ACCESSORIES
CodeProduct
MFX1114CO₂ High Pressure Hose 3/8 Male - Female, 1.25M
MFX1105CO₂ High Pressure Hose 3/8 Male - Female, 2M
MFX1106CO₂ High Pressure Hose 3/8 Male - Female, 3M
MFX1107CO₂ High Pressure Hose 3/8 Male - Female, 6M
MFX1108CO₂ High Pressure Hose 3/8 Male - Female, 10M
MFX1109CO₂ High Pressure Hose 3/8 Male - Female, 15M
MFX1110CO₂ 90 Degrees Connector 3/8
MFX1103CO₂ Bottle to Hose Connector
MFX1115CO₂ Bottle to Hose Connector 90 Degrees
Please contact MAGIC FX for additional possibilities.
1.5 CONFETTI
Accessories
The MAGICFX® STADIUMBLASTER can be set in 5 dierent angles between 45° and 90°. The output
height and output distance depends on the type of confetti and the set angle. The maximum load
per blast also depends on the type of confetti. Check the following table.
Type of confettiMax. load per blastOutput heightOutput distance
Metallic confetti20 kg12M25M
Paper confetti10 kg12M25M
Snow or Powder
confetti5 kg12M25M
Confetti types and related loads and output
NOTICE
Wind and other weather circumstances will inuence the output height and
output distance of the confetti. The given values are estimated values.
MAGICFX® STADIUMBLASTER — User and Installation Manual 7
1.6 DMX CONTROL
When connected to DMX the MAGICFX® STADIUMBLASTER is controlled with 1 safety address and 1
operational address:
DMX AddressAddress range
Safety1 - 512
Start1 - 512
DMX addresses
The Safety address cannot be the same as (one of) the operational address(es). Operating of
these addresses results in the following:
DMX AddressDMX Value (decimal)Result
099Device disabled
Safety
100155Device enabled
156255Device disabled
0199Valve closed
Start (output)
200255Valve open
Operation of the DMX addresses
When you link multiple machines with DMX, we advise you to use the same Safety address for all
machines.
CAUTION
Always plug in a DMX Terminator into the DMX output of the nal unit in the
control sequence. Using a DMX Terminator improves signal reliability.
8 MAGICFX® STADIUMBLASTER — User and Installation Manual
1.7 DISPLAY PANEL
MAIN MENU
DMX/RDM SETTINGS
BACKPREVNEXT
The display panel is located on the backside of the MAGICFX® STADIUMBLASTER. Check the
following menu structure for all options in the menu. Use the buttons for navigation and selection.
The le-hand LED blinks red when DMX is active. The right-hand LED blinks red when an error has
occurred.
SELECT
Display panel
Idle Display
Main Menu
Lock/Unlock Controller
DMX Start Address (1-512)
Reset Errors
DMX Safety Address (1-512)
DMX/RDM Settings
DMX Footprint (Fixed)
RDM (On/O)
Display Dimmer (On/O)
Conguration
Factory Defaults (Yes/No)
Error History
Unique ID
Soware Version
Information
Soware CRC
Bootloader CRC
Build Date
Menu structure
MAGICFX® STADIUMBLASTER — User and Installation Manual 9
1.8 RDM CAPABILITY
Remote Device Management Protocol (RDM) is an enhancement of the DMX512 communication
protocol. RDM can be used for conguration and status monitoring while DMX512 takes care of
the default controlling.
For RDM you will need a RDM compatible controller, cables and a RDM responder like the
MAGICFX® STADIUMBLASTER.
The following RDM parameters are supported by the MAGICFX® STADIUMBLASTER.
Parameter IDDiscoveryGETSET
DISC_UNIQUE_BRANCHX
DISC_MUTEX
DISC_UN_MUTEX
DEVICE_INFOX
SUPPORTED_PARAMETERSX
SOFTWARE_VERSION_LABELX
DEVICE_MODEL_DESCRIPTIONX
MANUFACTURER_LABELX
DMX_START_ADDRESSXX
IDENTIFY_DEVICEXX
DEVICE_LABELXX
FACTORY_DEFAULTSXX
SLOT_DESCRIPTIONX
RESET_DEVICEX
RDM parameters
RDM parameters are subject of change due to soware updates. Contact MAGIC FX for the latest
information and updates.
10 MAGICFX® STADIUMBLASTER — User and Installation Manual
2 BLAST SAFELY!
The MAGICFX® STADIUMBLASTER has been designed and constructed in such a manner that it can
be used safely. This applies to the use, the circumstances and the regulations as described in this
documentation. Reading this documentation and following the instructions are therefore
necessary for everyone who is authorised to work with the MAGICFX® STADIUMBLASTER.
The MAGICFX® STADIUMBLASTER must be placed and used in surroundings that preferably:
• Have a reasonably stable temperature of between -20 and 70°C.
• Have a relative humidity degree of no more than 90% (non condensing).
• Are reasonably free of dust, corrosive gases and high concentrations of organic vapours.
• Are not situated in the vicinity of a source of vibration.
2.1 GENERAL SAFETY RULES
• Only authorised persons may carry out work with the MAGICFX® STADIUMBLASTER.
• Do not use the MAGICFX® STADIUMBLASTER if there are people or animals in the direct output.
• Make sure that children, unauthorised people and animals do not obtain access to the
MAGICFX® STADIUMBLASTER.
• Make sure there are no freestanding objects or objects that can be damaged by the
MAGICFX® STADIUMBLASTER within the output distance.
• Do not connect more units to a single electrical circuit than the installed fuse is able to
handle. (Calculate the summed load with the electrical data from Section 1.2)
• Do not remove any safeguards, safety caps and safety symbols.
• All required safety devices must be in good condition and function properly.
• Ensure sucient lighting of the surroundings.
• Keep the workplace clean.
2.2 CO2
The MAGICFX® STADIUMBLASTER uses CO2 gas or liquid CO2 as input. The application of CO2
involves serious risks. Make sure that you are well informed on these risks before installation and/or
operation. Always use approved CO2 cylinders, hoses and connections. Always consult your CO2
supplier for regulations and instructions on safe installation and use.
MAGIC FX is not liable for unsafe situations, accidents and damage that are the result of incorrect
working with CO2 gas and CO2 cylinders.
Inadequate installation and/or operation of a CO2 powered machine and CO2
WARNING
cylinders can lead to death or serious injury. Always follow the instructions from
this manual, from your CO2 supplier and from local authorities.
2.3 INDOOR USE
The MAGICFX® STADIUMBLASTER is designed for outdoor use and use in well-ventilated indoor
spaces. When used indoors, make sure you take the necessary preparations. These preparations
could include, but are not limited to:
• Consulting your CO2 supplier.
• Calculating the reduction of oxygen for the indoor space.
MAGICFX® STADIUMBLASTER — User and Installation Manual 11
• Checking the location for spots where CO2 could accumulate and taking preventive actions.
• Installing CO2 monitoring devices that will warn for hazardous CO2 levels.
Do not use the MAGICFX® STADIUMBLASTER in poor ventilated conned spaces.
DANGER
Exposure to high levels of CO2 gas can cause symptoms like headache,
nausea, loss of consciousness or even death.
2.4 RIGGING
Please follow the European and national guidelines for safe rigging and trussing.
2.5 NOISE LEVEL
The environmental noise level as measured at the ear is 97 dB(A). This level of noise is only
reached during the short instances that the CO2 output is active. Therefore hearing protection is
not necessary.
Do not operate the MAGICFX® STADIUMBLASTER close to yourself or to others for
WARNING
a long period of time. If you experience any hearing loss or ringing in the ears,
you should immediately stop using the unit.
2.6 SAFETY SYMBOLS
The following safety symbols are present on the MAGICFX® STADIUMBLASTER.
SymbolMeaning
Read the manual carefully before use!
Safety symbols
2.7 PRECAUTIONS FOR OPERATION
Using a damaged or an improper installed machine can lead to death, serious
WARNING
WARNING
injury or property damage. Always inspect the machine thoroughly before
operation.
Missing or obscured safety symbols on the machine can lead to death, serious
injury or property damage. Make sure all safety symbols are correctly in place and
visible, see Section 2.6.
CAUTION
12 MAGICFX® STADIUMBLASTER — User and Installation Manual
A missing or loose-tted woofer can lead to injury. Make sure that the woofer is
correctly in place on the bayonet connection and secured with the safety steel.
3 LET’S BLAST!
3.1 INSTALL THE MACHINE
1 Bring the cased MAGICFX®
STADIUMBLASTER to the desired location.
2 Unlock and remove the top cover.
MAGICFX® STADIUMBLASTER — User and Installation Manual 13
3 Unlock and remove the cover from the
bottom cabinet.
4 Take out the woofer.
5 Screw the woofer rmly onto the bayonet socket of the hopper until it locks in place.
14 MAGICFX® STADIUMBLASTER — User and Installation Manual
6 Secure the woofer with the safety steel.
7 Optionally you can set the hopper with
the attached woofer in one of the
5 pre-set angles.
MAGICFX® STADIUMBLASTER — User and Installation Manual 15
8 1. Create a safety zone of 2 m around
4
5
˚
the MAGICFX® STADIUMBLASTER.
2. Make sure that the direct output will
be free from persons and animals.
3. Make sure there are no freestanding
objects or objects that can be
damaged by the MAGICFX
STADIUMBLASTER within the output
distance.
9 Place the MAGICFX® STADIUMBLASTER in
its nal position and set the brakes.
®
2 m
4 m
10 Make sure the manual CO2 valve is in
CLOSED position.
16 MAGICFX® STADIUMBLASTER — User and Installation Manual
11 Connect the CO2 hose to the CO2 quick
connector.
12 Connect a CO₂ bottle-to-hose connector
to a CO2 cylinder.
13 Connect the CO2 hose to the CO₂ bottle-
to-hose connector on the CO2 cylinder.
MAGICFX® STADIUMBLASTER — User and Installation Manual 17
14 Open the CO2 cylinder.
15 In case of multiple machines: Repeat steps 1-14 for each machine.
3.2 FILL WITH CONFETTI BEFORE EACH BLAST
1 Unlock and open the lid of the hopper.
2 Fill the hopper with confetti. Check Section 1.5 for the maximum amount per type of confetti.
18 MAGICFX® STADIUMBLASTER — User and Installation Manual
3 Close and lock the lid of the hopper.
4 In case of multiple machines: Repeat steps 1-3 for each machine.
3.3 BLAST MANUALLY
1 2Make sure that the prescribed safety
zone is free from persons and objects.
When it’s time to blast, move the manual
CO
valve in OPEN position.
2
3 Enjoy the view!
MAGICFX® STADIUMBLASTER — User and Installation Manual 19
4 When the hopper is out of confetti, move
the manual CO2 valve back in CLOSED
position.
3.4 CONNECT 24 V CONTROL
24V24V
1. Connect two cables to the 24 V input.
2. Connect the other ends of the cables to your controller.
NOTICE
NOTICE
20 MAGICFX® STADIUMBLASTER — User and Installation Manual
No additional power source is needed. The controller provides power to the
MAGICFX® STADIUMBLASTER to open and close the output valve.
The FX LED indicator and the display and buttons are inactive when control is
applied. The controller only powers the output valve.
3.5 BLAST WITH 24 V CONTROL
1. Make sure that the prescribed safety zone is free from persons and objects.
2. When it’s time to blast, continuously, enable the output on your 24 V controller and make
sure to produce a continuous pulse.
3. Enjoy the view!
4. When the hopper is out of confetti, disable the output on your 24 V controller..
3.6 CONNECT POWER AND SETUP DMX
5-pole female
DMX
PowerCon TRUE1 female
POWER
1. Connect a power cable with a Powercon TRUE1 Female connector to the power input.
2. Connect the other end of the power cable to a 100-250 Vac (50-60Hz) power source.
3. Connect the female connector of a 5-pole DMX cable in the DMX input.
4. Connect the other end of the DMX cable to your DMX controller.
5. Use the display and buttons or a RDM controller to assign DMX addresses, see chapter 1.
CAUTION
Always plug in a DMX Terminator into the DMX output. Using a DMX Terminator
improves signal reliability.
MAGICFX® STADIUMBLASTER — User and Installation Manual 21
3.7 SETUP MULTIPLE MACHINES IN A SEQUENCE WITH DMX
5-pole male
5-pole female
DMX
PowerCon TRUE1 male
PowerCon TRUE1 female
POWER
1. Connect a power link cable to the power output.
2. Connect the other end to the power input of the next machine.
3. Connect a DMX cable to the DMX output.
4. Connect the other end to the DMX input of the next machine.
5. Use the buttons or a RDM controller to assign DMX addresses, see chapter 1.
6. Repeat step 1 to 5 for each subsequent machine.
CAUTION
3.8 BLAST WITH DMX
1. Make sure that each prescribed safety zone is free from persons and objects.
2. Activate the Safety address. The FX LED indicator on each machine lights up.
3. When it’s time to blast, activate the Start address.
4. Enjoy the view!
Always plug in a DMX Terminator into the DMX output of the nal unit in the
control sequence. Using a DMX Terminator improves signal reliability.
5. Deactivate the Start address when the hopper is out of confetti,
22 MAGICFX® STADIUMBLASTER — User and Installation Manual
3.9 REPLACE A CO2 CYLINDER
1 Make sure that:
• the manual CO
valve is in CLOSED
2
position.
• the DMX Safety address is not
activated (FX LED indicator is
dimmed).
• the 24 V controller (if used) is not
powered.
2 Close the connected CO2 cylinder.
3 Move the manual CO2 valve in OPEN
position to release the pressure from the
system.
4 Move the manual CO2 valve back in
CLOSED position.
MAGICFX® STADIUMBLASTER — User and Installation Manual 23
5 Disconnect the CO2 hose from the CO₂
bottle-to-hose connector on the CO2
cylinder.
6 Remove the CO₂ bottle-to-hose
connector from the cylinder.
7 Connect a CO₂ bottle-to-hose connector
to a new CO2 cylinder.
24 MAGICFX® STADIUMBLASTER — User and Installation Manual
8 Connect the CO2 hose to the CO₂ bottle-
to-hose connector on the new CO2
cylinder.
9 Open the CO2 cylinder.
10 In case of multiple machines, connected in series: Repeat step 1-9 for each machine.
3.10 CLEAN UP
1
Deactivate the Safety address
(FX LED indicator on each machine dims).
2
Disconnect any 24 V, DMX and power cable(s).
3
Close the CO2 cylinder.
MAGICFX® STADIUMBLASTER — User and Installation Manual 25
4 Move the manual CO2 valve in OPEN
position to release the pressure from the
system.
5 Disconnect the CO2 hose from the CO2
quick connector.
6 Disconnect the CO2 hose from the CO₂
bottle-to-hose connector on the CO2
cylinder.
26 MAGICFX® STADIUMBLASTER — User and Installation Manual
7 Remove the CO₂ bottle-to-hose
connector from the cylinder.
8 Wait until the ice crust on the output has melted.
9 In case you have set the hopper under an angle: Position the hopper back in horizontal
position (position 1).
MAGICFX® STADIUMBLASTER — User and Installation Manual 27
10 Remove the safety steel.
11 Remove the woofer.
12 Store the woofer in the cabinet.
28 MAGICFX® STADIUMBLASTER — User and Installation Manual
13 Place and lock the cover of the bottom
cabinet.
14 Unlock and open the lid from the hopper.
15 Remove remaining confetti from the
hopper.
MAGICFX® STADIUMBLASTER — User and Installation Manual 29
16 Close and lock the lid from the hopper.
17 Place and lock the top cover.
18 Release the brakes.
30 MAGICFX® STADIUMBLASTER — User and Installation Manual
4 MAINTENANCE
To achieve the maximum service life of the MAGICFX® STADIUMBLASTER you must regularly clean
the MAGICFX® STADIUMBLASTER and test if it is functioning correctly.
Contact MAGIC FX if the MAGICFX® STADIUMBLASTER is not functioning correctly.
DANGER
Do not replace parts yourself; always consult MAGIC FX.
5 TROUBLESHOOTING
Always contact MAGIC FX if any malfunctions or errors occur that cannot be solved with the
instructions as described in this manual.
6 CORRECT DISPOSAL
This symbol on the product and / or accompanying documents means that
used electrical and electronic products (WEEE) should not be mixed with
general household waste. For proper treatment, recovery and recycling,
please take this product to designated collection points where it will be
accepted free of charge.
Alternatively, in some countries you may be able to return your products to
your local retailer upon purchase of an equivalent new product.
Disposing of this product correctly will help save valuable resources and
prevent any potential negative eects on human health and the environment, which could
otherwise arise from inappropriate waste handling.
Please contact your local authority for further details of your nearest designated collection point.
Penalties may be applicable for incorrect disposal of this waste, in accordance with your national
legislation.
MAGICFX® STADIUMBLASTER — User and Installation Manual 31
7 EC DECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY
According to Annex III A Low Voltage Directive 2014/35/EU + Machinery Directive
2006/42/EC
MAGIC FX B.V. declares as manufacturer and composer of the technical construction file that the
product with the following specifications:
Name machine: STADIUMBLASTER
Type: MFX0803
Voltage: 100-250Vac 50-60Hz
Serial number: on product
Year of construction: on product
Is in conformity with the minimal safety regulations as stated in the following directive(s):
•EMC (2014/30/EC) ElectroMagnetic Compatibility
•RoHS (2011/65/EU) Restriction of the use of certain Hazardous Substances
•NEN-EN-ISO 12100:2010 Safety of machinery - General principles for design - Risk
assessment and risk reduction.
•NEN-EN-IEC 60204-1:2006, Safety of machinery - Electrical equipment of machines - Part 1:
General requirements.
•NEN-EN-IEC 61000-6-3:2007/A1:2011, Electromagnetic compatibility (EMC) - Part 6-3:
Generic standards - Emission standard for residential, commercial and light-industrial
environments.
Original declaration of conformity
Translation of the original declaration of conformity
Name manufacturer: MAGIC FX BV
Address: Schouwrooij 27, 5281 RE BOXTEL
Country: The Netherlands
CEO: B. Veroude
Date: 17-01-2017
Signature:
32 MAGICFX® STADIUMBLASTER — User and Installation Manual
MAGICFX® STADIUMBLASTER — User and Installation Manual 33
MAGIC FX B.V.
Schouwrooij 27
NL-5281 RE BOXTEL
The Netherlands
T. +31(0)411 63 50 13
F. +31(0)411 63 50 12
E. info@magicfx.eu
Chamber of commerce : 17178664
V.A.T. : NL814544228B01
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.