MCT’s Multipoint USB over LAN WorkStation MWS9940 leverage new Microsoft Windows
Server 2011 technology, providing Plug-and-Play USB and GIGA-LAN Solution that
transforms single computers into Multiuser Workstation, and turn it into a distance free Zero
Client device.
MWS9940 powers M ultiPoint Workstation 2011 system in full features allowing one
computer to server up to 10 workstations (Figure 1) without adding 2nd system or any excess
graphic card, great for cost saving!
MWS9940 simply connect it to Gigabit Ethernet Port on the server and attach a monitor,
keyboard, and mouse to add a new workstation. The MWS9940
features two high-speed USB 2.0 ports, audio and microphone ports, a VGA port that
supports resolutions up to 1600 x 1200
The MWS9940 provides an inexpensive and reliable way to expand your Windows
MultiPoint Server 2011 for school and office running “office application"
“Home Entertainment” and “Full Screen Movie Playback” are not recommended.
Microsoft, Active Directory, MultiPoint Server, Office, .NET Framework, Windows, and Windows Server are trademarks of
the Microsoft group of com panies . All other t r adema rks are property of t heir r espect ive owners .
MULTIP OINT USB OVER LAN WORKSTATION M
4
WS9940
MINIM UM SYSTEM REQU IREMENTS
• Available Gigabit Ethernet port or Gigabit Ethernet extension card.
• Compatible processor (MultiPoint Server supports up to four core & eight core CPUs on
one server)
Note:
1) AMD Opteron / Athlon, AMD Embed chipset is not recommend due to unstable
keyboard/mouse operation which may not recognize under USB1.1 device.
2) Intel Itanium Processor is not supported.
RAM – The required RAM depends on the number of MultiPoint USB OVEN LAN
Workstation MWS9940s that are connected to the computer:
• DRAM 2GB for 4 stations
• DRAM 4GB for 6 stations
• DRAM 8GB for 10 stations
Multi-core processor support
• Support up to 4 & 8 multi-core processors; dual-core is less powered and therefore
only 2 to 3 workstation can be supported.
Minimum disk space for setup
• 32 GB
MULTIP OINT USB OVER LAN WORKSTATION M
5
WS9940
Figure 1 10-Seat Implement at ion of Windows Mult iPoint Server2011 wit h using MWS9940
FEATURES
Ethernet connect ion the host server with distance free
Simple plug and play setup
Eliminates the need for internal video card installation
Designed for Microsoft Windows MultiPoint Server 2011
Simplified administrat ion
Up to 10 WorkStations per Server PC
Average of 95% power reduction compared to a conventional PC
Ideal for education, call centers, computer labs and home offices as well as SMB and
government
MULTIP OINT USB OVER LAN WORKSTATION M
6
CONNECTIONS AND MOUNTING KITS
Power jack – 5V/3A DC in
Reset Function port (Recall Firmw are Default)
1 VGA Port (Resolutions up to 1600 x 1200 (1600 x 900 system recommend)
1 Gigabit Ethernet Port
Stereo Audio Output (Speaker/Headphone) and Mono audio input (Mic)
2 USB 2.0 Ports for Keyboard and Mouse / Plug-and-Play compliant
Optional usage for USB connection:
Select one USB port for Wireless Keyboard and mouse, therefore,
The second USB connector can be used for flash drive or External USB Storage
CONNECTIONS
WS9940
OPTIONAL USB CONNECTIONS
7
Monitor
MWS9940 Unit
BACK VIEW
100x100mm VESA HOLES
ON MONITOR
VESA mounting
VESA mounting
3A
DC 5V RESET
VESA MOUNTS
Follow up the picture illustration below:
MULTIP OINT USB OVER LAN WORKSTATION M
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
8
OPERA TING SYSTEMS SUPPORTED
For optimal multimedia performance, we recommend the following CPUs:
Dual-core processor: support up to 3 stat ions under low process ing applica tion.
Quad-cor e processor: support up to 6 stations under low processing application.
Core-i5 processor: support up to 6 stations under low processing applicat ion.
Core-i7 processor: support up to 6 or 10 stations under low pr ocessing application.
Windows MultiPoint Server 2011
FOR OPTIMUM VIDEO DISPLAY
Full screen video display is not recommended, user may try one station for full screen
video play back under 720P periodically. a higher system may required for full screen
video play back, please refer to following specification:
- i7 processor
WS9940
- Intel Sandy bridge chipset
Note: Extended video display at full screen is not recommended; it often exhausts CPU and
force system with much lower performance.
REGULATORY COMPLIANCE
FCC / CE / C-tick / VCCI
Tested to comply with FCC Standards.
PACKAGE CONTENTS
• MW9940
• Mounting kits
• Ethernet Cable
• 3A/5V AC Power Adapter
• CD (Driver and User’s Manual)
• Quick Install Guide
MULTIP OINT USB OVER LAN WORKSTATION M
9
SUPPORTED DISPLAY RESOLUTIONS
WS9940
NOTE
Always prepare devices as how many stations as the user plan to build up. Then classify
into the Mac addresses for different servers. In order to better organize for different locations,
the table as bel ow is strongly recommended to use for pasting the Mac address whi le in the
build-up process. This is also as a reference for users so as to move or add additional
WorkStation if needed
10
.
MULTIP OINT USB OVER LAN WORKSTATION M
WS9940
Table 1
MULTIP OINT USB OVER LAN WORKSTATION M
11
WS9940
Table 2
MULTIP OINT USB OVER LAN WORKSTATION M
12
WS9940
DEVICE IN STALLATIO N - SOFTWARE
Installing the device driver enables Windows MutliPoint Server 2011 to recognize the
MWS300UV2. Please make sure the MWS300UV2 is unplugged from your server
before executing the setup program.
Step 1
Insert the Driver installation CD into the CD-ROM drive. The installer should start
automatically. If it does not, double click Setup.exe to start the Installation Wizard.
Step 2
Driver Installat ion W izard, click Next to continue
MULTIP OINT USB OVER LAN WORKSTATION M
13
WS9940
Step 3
License Agreement; review it and check I accept the terms of the license agreement Click
Next to accept the License Agreement.
MULTIP OINT USB OVER LAN WORKSTATION M
14
Step 4
Setup is searching for installed features... *You may notice the screen flashes during
hardware installation. It is part of the normal process. .
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
15
Step 5
Driver Installat ion W izard, click Finish to continue and restart the computer.
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
16
THE STATIONS ASSIGNMENT
BUILDING WORKSTATION ON SINGLE SERVER ONLY
Step 1
The “MultiPoint Manager” page will be auto-displayed in a
minute after system boot-up and administrator log-in.
NOTE: If this page did not pop out automatically, please foll ow the illustrate below: 1. Start
-> 2. All Programs -> 3. MultiPoint Manager
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
17
Step 2
Click “Network Stations” as showed:
Step 2-1
When there is 3 workstation HUB is connected,
It shows 3 stations on the screen which are free / waiting for
assignment inside the “status” column indicating as “not
connected”.
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
18
Step 3
Click the block “□” t o s elect one of the stations under t he
column on the left side of the “cli ent Name” and then click
“Assign to this server ” at the ri ght column as illustrated.
Step 3-1
If all of the stations need to be selec ted, simply
click “Select All” at the right column under “Device Task Item”.
After that, you will fi nd all of the stations are selected as the
blocks “□”. Then, click “A ssign t o this server”.
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
19
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
20
Step 4
Click “Yes” to complete the station assignment.
Repeat the same process of step3 – 4 for the any
other one of the stati on y ou desire t o sel ec t f or station assignment.
Step 5
The status column will show “Connected” workstation at lower
section of the screen.
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
21
NOTE: If any one of the stations needs to be disconnected,
please select the station and Clic k “Clear Assignment” under
“Device Task Item” on the right panel of the screen then cli c k
“Yes” while the dialog pop up for disconnection.
WS9940
If all of the stations need to be disconnected, simply
click “Select All” at the right column under “General Task Item”.
After that, you will fi nd all of the stations are selected as the
blocks “□” and click “Clear Assignment” then click “Yes” while
the dialog pop up for di sconnection.
MULTIP OINT USB OVER LAN WORKSTATION M
22
STATIONS RENAME
Renaming the station may convenient administrat or r ecogni z ing
MAC address location by his own design, it needs to be done
before station gets assignment.
Rename step:
1. Select station by one left click
2. Left click on “Rename” at right panel
3. Rename dialog will pop up then typing
desire name (e.g. CL1-J ohn, CL2-Josh)
4. Click “Submit” to complete
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
23
NETWORK SETTING
A Local Area Network setting to be prioritize either by Static IP or Dynamic IP for this Server, this Network
Setting needs to be done before station gets assigned. “Dynamic IP ” i s recommend with Router Device
1. Select station by one left click highlight
2. Left click on “Network” under “Device Ta s k Item”
3. Network setting dialog will pop out then left click the DHCP for auto distributing the IP address or manually
type the IP address then clic k “Submit” on the dialog to complete.
WS9940
:
RESTART DEVICE
Restart Device function can be use when there are some station did not rec ognize keyboard/mouse.
“Restart device” needs to be done before station gets assignment. Restart device step:
1. Select station by one left click highlighting
2. Left click on “Restart device” under “Device Task Item.”
3. Click “Yes” on the dialo g to complete
MULTIP OINT USB OVER LAN WORKSTATION M
24
UPDATE FIRMWARE
Station “Update firmware” needs to be done before station gets assignment. Restart device step:
1. Select stati on by one l eft click highlighting
2. Left click on “Update firmware” under “Device Task Item”
3. Select the firmware file then click “Submit” to complete.
NOTE: Please contact with the distribut or where you bought t he dev ic e for firmware upgrade.
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
25
WS9940
QUICK SET WORKSTATIONS
Under Local Area Net work envir onm ent, multiple server may often exist and r equired to be use, each server
linked with a group of workstation and all workstation (MAC addr ess) m ay appear on ev er y server’s system
manager, theref or e admi nistrator needs to clarify whic h workstati on linked with particular server by keeping
each MAC address in handbook and able t o r enam e it.
Please refer to the Figur e 1 as an example f or depl oyi ng 5 stations onto 2 Server (Server A and Server B).
Figure 1
Label the MAC address into the tabl e 1 or 2 bef ore setting up the station as the picture shown below.
Always follow up the discription of point 1 (MAC ADDRESS REMARKING) before setting up the stations)
MULTIP OINT USB OVER LAN WORKSTATION M
26
Step 1 - Label remarking MAC address and save for records. Label the MAC addresses onto the table 1 for
Server A and Server B -Grouping Server ‘A’ devices (MWS9940) and peel the Mac address labels from the
back side of the HUB device. Then paste it on the Server ‘A’ page of the Handbook “Table 1” as provided in
the QIG.
Step 2
Boot the server ‘A’ after connec ting all the stations over Gigabit switch hub. It shows 5 stations on the
screen which are free for assignment as well as the “status” column indicate with the message “not
connected”.
Step 2-1
Select and matching the stati ons one by one as assigned and pasted on the Server ‘A’ Col um n of t he
table 1 in step 1. Then left click “Assign to this server ”under “Device Task Item” to complete assignment.
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
27
Step 3
The status column on the bottom of the screen shows “Connected” while the assignments for Server ‘A’
completed.
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
28
Step 4
Select and match for the stations one by one as assign ed and pasted on the Server B Column of the
table 1 in step 1. Then left click “Assign to this server ”under“ Device Task Item” to complete
assignment.
WS9940
NOTE:
The host PC will show the 2-assigned workstat ion of server ‘B’ at lower part of t he screen while the other 2
assigned station of ‘A’ server is showed on the mid of screen, meantime there is one ‘free station’ waiting to
be assign for any other serv er .
MULTIP OINT USB OVER LAN WORKSTATION M
29
VERIFYING THE MWS9940 CONNECTION
Step 1
Please follow up the illustration below: 1. Start -> 2. All Programs -> 3. MultiPoint
Manager(under Windows MultiPoint Server folder)
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
30
Step 2
Click “Device Manager” then select “Devices by
connection” as the picture
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
31
Step 3
Extend “Network USB Server Bus” trees for al l the
input and output devices as the picture for
verification whether all of the devices have been
successfully connected.
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
32
WS9940
ADJUSTING THE SCREE N RESOLUTI ON
By default, Windows MultiPoint Server 2011 will select the recommended resolution for each
connected display. However, if you would like to choose a different resolution, follow these
steps:
Step 1
Please follow up the procedure on illustration for getting into “MultiPoint Manager” as 1. Start
-> 2. All Programs -> 3. Windows Multipoint Server -->MultiPoint Manager
MULTIP OINT USB OVER LAN WORKSTATION M
33
Step 2:
Go to MultiPoint Manager => Home =>Local Station => switch to maintenance mode
WS9940
Step 3:
Click OK to continue
Step 4
Press “Ctrl + Alt + Delete” to log in administrator into Maintenance Mode
MULTIP OINT USB OVER LAN WORKSTATION M
34
Step 5
Right click on the desktop and choose Screen Resolution from the contextual menu.
WS9940
Step 6
Click Identify to identify each display. Then click on the display to be adjusted and choose
the desired resolution from the Resolution dropdown menu.(suggest: better using the
system recommend resolution)
MULTIP OINT USB OVER LAN WORKSTATION M
35
WS9940
DEVICE DRIVER UN-INSTALLATION
The following procedure allows you to uninstal l the MWS9940 device driver. Please
make sure all MWS9940 are Clear assignment from your (Network Stations) before
executing the device d river uninstallation program.
Step 1
1. Click Start -> 2. All Programs -> 3. Control Panel
Step 2
Double click “Uninstall a program” as illustrated on the screen.
36
Step 3
MULTIP OINT USB OVER LAN WORKSTATION M
WS9940
Select the “Magic Control Technology – MWS xx.xx.xxxx.xxxx” item. Click Uninstall button.
MULTIP OINT USB OVER LAN WORKSTATION M
37
WS9940
Step 4
Click “OK” to continue
Step 5
Select “Yes, I want to restart my computer now” and click “Finish” to reboot. The driver is
now uninstalled.
38
SPECIFICATIONS
MULTIP OINT USB OVER LAN WORKSTATION M
WS9940
MULTIP OINT USB OVER LAN WORKSTATION M
39
WS9940
REGULATORY COMPLIANCE
FCC
This equipment has been tested and found to comply with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
• This device may not cause harmful interference
• This device must accept any interference received, including interference that may cause
undesired operation.
CE
This equipment is in compliance with the requirements of the following regulations:
EN 55022: CLASS B (2006),
IEC/EN 61000-3-2 (2006), IEC/EN 61000-3-3 (1995+A1:2001+A2: 2005 )
EN 55024 (1998+A1 :2001+A2 :2003), (IEC/EN 61000-4-2 (1995+A1:1998+A2:200 1)
/-3 (2006)/-4 (2004)/-5 (2006)/-6 (1996+A1:2001)/-11 (2004))
For EU-member states:
The use of the symbol indicates that this product may not be treated as
household waste. Waste electrical and electronic equipment should be
appropriately collected and recycled as required by practices established for
your country. For the information on recycling of this product, please contact
your local authorities, your household waste disposal service or the shop
where you purchased the product.
KNOW FACT ORS & NOTE
SCHOOL ENVIRONMENTAL AND BEHAVIOR MATRIX
MWS means to simplify operation and provide safety environment in the class room!
Teacher turn on computer first thing when the day begin, one button that turns on all station
power simultaneously and continue all day with auto-mappi ng enables each individuals
operation; turn off computer at end of date that shut down all station power as well.
When student walk in the classroom, he/she only needs simply turn on the monitor and log
in, then log out the workstation and turn off monitor after class; that leaves power idle t hus
convenient next class enable fast log on. For safety reason, nobody has to touch any
device’s power or USB connector to avoid strange behavior that may cause electronic power
shock.
MULTIP OINT USB OVER LAN WORKSTATION M
40
WS9940
1. Disconnecting a Workstation while videos are playing may cause stability issues. Do
not disconnect Workstations during video playback.
2. Using different display resolutions on workstations may cause display issues if a station
is disconnected. Set all workstations to the same resolution for the best performance.
3. Video play back performance is rely on USB2.0 bandwidth and limited to maximum
bandwidth of 480 Mbit/s [60 MB/s] , therefore smaller scale display window at lower
resolution is recomm end.
4. When all station needs for video playback, smallest scale window is recommended.
eg. when all 10 station playing youtube, keep every video frame at original or smallest
size. for better perfor mance, upgrade to a higher level CPU and increase memory is
recommended.
5. Multi-Video Playback at each workstation is not recommended, it occupied CPU's
loading and lower each task performance, it could cause operation freeze when CPU
consumption is over its limited.
6. Prior to installing the MCT driver, the computer should be running the most current build
of Windows MultiPoint Server 2011 and have the appropriate graphics card driver from
the list showed at "System Requirement" page.
7. Due to Ethernet bandwidth limitation, for smooth playing performance, minimize video
playback landscape is recommended when multiple videos playing across many
monitors simultaneously, scale are recommended as below:
- 2 users: full screen
- 4 users: 1/3 landscape
- 6 users: 1/4 landscape
- 8~10 users: 1/8 landscape
8. MWS9940 is default for 10 stations at the moment, excess station is to be requested.
Driver instal la tion may take 2 to 3 minutes. Initial mapping may take 5 minutes for 10
stations after driver installed. Regular rebooting may take 3 to 4 minutes to get auto
mapping on all stations.
TROUBLESHOOTING TIPS
The following troubleshooting tips may help if you are experiencing any difficulties using our device.
• Check to see that the monitor is connected correctly and the power is ON.
• Make sure to restart the server after the driver installation.
• When disconnect the power adapter or Ethernet cabl e, wait for a few seconds for re-connecting it.
•
Check the website to make sure you have the latest drivers.
• Reset/refresh/r esynchr onize your monitor if t he screen is not in pr oper ( c enter) .
Full sc ree n vide o dis play is not reco mmende d; use I ntel Sand y Bridge c hips et ma y help wit h better
•
performance.
DRIVERRELESENOTED
For immediate support, visit MCT's websi te: http://www.mct.com.tw to find the updat e driver,
Knowledge Base arti cl es, and software for your device. You can also chat live with a support technici an or
submit a trouble ti cket .
.