This Data Sheet Includes Information On
Magic Chef
• Product Model Number (s): •
Gas Cooktops:
8241RB, 8241RT, 8241RV, 8241RS, 8241RW, 8241RA
and 8241RQ
• Dimensions (Actual Size) •
Overall width:
Overall depth:
Distance from countertop to bottom of unit:
Cut-Out width:
Cut-Out depth:
30"
21"
3 3/8"
28 3/8"
19 3/4"
Minimum spacing to nearest vertical
combustible wall to the RIGHT:
3"
Minimum spacing to nearest vertical
combustible wall to the LEFT:
3"
Minimum spacing to nearest vertical
combustible wall to the REAR:
Minimum spacing to front edge of counter:
1"
2"
Minimum distance between cooktop
and cabinet directly above:
Minimum width of cabinet directly above:
30" min
30"
Maximum depth of cabinets directly
above and adjacent:
13"
Minimum distance between countertop
and adjacent cabinet above:
18"
• Additional Information •
• Designed to fit in a standard 30" wide cabinet and 25"
deep countertop.
• Electrical requirements: 120 volts 60 Hz protected by
a 15 amp fuse or compatible circuit breaker. Minimum
wire size is 14 gauge. Copper wire only. Unit is
supplied with a power cord having a 3-prong grounding
plug. A grounded and polarized 3-prong receptacle
should be made available. Individual branch circuit
serving the cooktop is recommended.
• Gas requirements: Supply line should be 3/4" and
enter the cooktop in right rear corner of unit. Unit is
shipped from factory for use on natural gas. Unit is
equipped with built-in conversion for use on LP gas.
- Supplied with 1/2" NPT female inlet on regulator.
Regulator supplied with unit and a shutoff valve must
be installed in an accessible location.
- Gas pressure requirements: Natural gas- 4" WC min,
14" WC max. LP gas- 10" WC min, 14" WC max.
3 3/8"
Side View (not to scale)
1"
19 3/4"
28 3/8"
2"
3" 3"
30" min
18"
2 1/16" to centerline of pipe from
back edge of cutout
30"
21"
Overall Dimensions
Top View (not to scale)
Cut-Out Dimensions
Countertop View
(not to scale)
Cabinet Requirements
Wall View
(not to scale)
30"
Requires 18" high by
3" wide clearance to
any combustible
surface above the
cooktop on both sides.
(noted by solid area)
Gas inlet location
1 5/16" to centerline
of pipe from left edge
Top view of cutout
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
252
Cooktop supplied with 1/2" NPT female inlet on regulator
(not to scale)
of cutout
BN • A252 • 31510 • 030805 • 10859 • 73846