VOLT101A
DC VOLTAGE DATA LOGGER
Features
• 10 Year Battery Life
• 4 Hz Reading Rate
• Multiple Start/Stop Function
• Ultra High Speed Download
• 1 Million Reading Storage Capacity
• Memory Wrap
• Battery Life Indicator
• Optional Password Protection
• Programmable High and Low Alarms
• Field Upgradeable
Benefits
• Simple Setup and Installation
• Minimal Long-Term Maintenance
• Long-Term Field Deployment
Applications
• Low Level Signal Monitoring
• Battery Studies
• Power Supply Monitoring
• Process Plants
• Research and Development
• General Purpose Voltage Recording
MadgeTech’s Volt101A data loggers are versatile
data logging devices with many uses and
applications. Connect negative and positive wire
leads directly to the terminal port on the Volt101A
to monitor and measure voltage levels. The
Volt101A is commonly used to assess battery
efficiencies or photovoltaic studies to identify how
much energy is being created from solar cells.
The Volt101A features a removable terminal
block to allow for simple retrieval of the data logger for downloading while leaving the leads
connected. With a ten year battery life and the ability to store up to one million time and
date stamped readings, this device is ideal for long term deployment and voltage studies.
Four models of the Volt101A are available. The 2.5 V is capable of measuring -3V to 3 V, the
15 V capable of measuring -8 V to 24 V, and the 30 V which can measure from -8 V to 32
V. For lower voltage applications that require a higher resolution, MadgeTech also offers the
Volt101A 160 mV model, which can measure voltage between -160 and 160 mV.
MADGETECH DATA LOGGER SOFTWARE
A
Key
A Graph View
B Tabular Data View
C Statistics
D Digital Calibration
E Copy to Excel®
B
C
E
D
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
Software Features:
• Multiple graph overlay
• Statistics
• Digital calibration
• Zoom in/ zoom out
• Lethality equations (F0, PU)
• Mean Kinetic Temperature
• Full time zone support
• Data annotation
• Min./Max./Average lines
• Data table view
• Automatic report generation
• Summary view
• Multilingual
VOLT101A SPECIFICATIONS*
Input Connection: Removable screw terminal
Model: 2.5V 15V 30V
Voltage Range: -3 to +3V -8 to +24V -8 to +32V
Voltage Resolution: 0.1 mV 0.5 mV 1.0 mV
Calibrated Accuracy: ±0.05% FSR at 25ºC
Input Impedance: 125kΩ
Overload Protection: ±50 V, indefinitely
Analog Conversion Time: 150 ms
Frequency Rejection: 50/60Hz
Reading Rate:
Memory:
Wrap Around Yes
Start Modes:
Stop Modes:
Multiple Start/Stop Mode:
Multiple Start/Stop
Mode Activation:
Real Time Recording:
LED Functionality:
4 readings every second up to 1 reading
every 24 hours
• 1,000,000 readings; software configurable
memory wrap
• 330,000 readings in multiple start/stop mode
• Immediate start
• Delay start up to 18 months
• Multiple pushbutton start/stop
• Manual through software
• Timed (specific date and time)
Start and stop the device multiple times
without having to download data or
communicate with a PC
• To start the device:
Press and hold the pushbutton for 5
seconds, the green LED will flash during this
time. The device has started logging.
• To stop the device:
Press and hold the pushbutton for 5 seconds,
the red LED will flash during this time. The
device has stopped logging.
The device may be used with PC to monitor
and record data in real time
User selectable high and low limits; blinking
Alarm:
LED for alarm and low battery
• Green LED blinks:
10 seconds to indicate logging
15 seconds to indicate delay or manual start
mode - standby (waiting to start)
• Red LED blinks:
10 seconds to indicate low battery and/or
memory
1 second to indicate an alarm condition
Password Protection:
Engineering Units:
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Battery Type: 3.6V lithium battery included; user replaceable
Battery Life:
Data Format:
Time Accuracy: ±1 minute/month (at 25 ºC, stand alone logging)
Computer Interface: USB (interface cable required); 115,200 baud
Operating System:
Operating Environment: -40 ºC to +80 ºC, 0 %RH to 95 %RH non-condensing
Dimensions: 1.4 in x 2.1 in x 0.6 in (35 mm x 54 mm x 16 mm)
Weight: 0.9 oz (24 g)
Materials: ABS plastic
Approvals: CE
BATTERY WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT,
CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE.
BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 80 °C (176 °F).
*SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC WARRANTY AND REMEDY LIMITATIONS APPLY. CALL 1-603-456-2011 OR GO TO WWW.MADGETECH.COM FOR DETAILS.
An optional password may be programmed into the
device to restrict access to configuration options. Data
may be read out without the password.
Native measurement units can be scaled to display
measurement units of another type. This is useful
when monitoring voltage outputs from different types
of sensors such as temperature, CO2, flow rate and more.
10 years typical at a 15 minute reading rate
Graph display of the device recording in a 25 °C environment.
Date and time stamped V, mV, μV, engineering units
specified through software
XP SP3/Vista/Windows 7/Windows 8
MadgeTech Software 2.03 or higher required
ORDERING INFORMATION
MODEL DESCRIPTION
VOLT101A-2.5V 2.5 V Voltage Data Logger
VOLT101A-15V 15 V Voltage Data Logger
VOLT101A-30V 30 V Voltage Data Logger
IFC200 Software, manual and USB interface cable
Calibration Calibration Certificate available for data logger
LTC-7PN Replacement battery for Volt101A
For Quantity Discounts call 603-456-2011 or email sales@madgetech.com
6 Warner Road · Warner, NH 03278
Phone: (603) 456-2011 · Fax: (603) 456-2012
Temperature
ASK ABOUT
OUR OTHER
DATA
LOGGERS
DOC-1210009-00 REV 10 2014.12.16
Humidity
Pressure
pH
Level
Shock
LCD Display
Pulse/Event/State
Current
Voltage
Wireless
Intrinsically Safe
Spectral Vibration
Motion